Allen Bradley 849 Timing Relays 849A-ZAD25

Product image is representative; revision or series may vary. Contact us to request a specific version.

849A-ZAD25

|

The timer unit with product code 849A-ZAD25 is designed and manufactured by Allen-Bradley/Rockwell Automation and it is available through the Bulletin 849A series. The unit features “off delay” capabilities and it is a pneumatic device made for counting applications. This Series C unit has a NEMA Type 1 rated enclosure and it provides a timing range of 0.05 to 180 seconds.

In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Rockwell Disclaimer: The product is used surplus. DO Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because DO Supply is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. DO Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. DO Supply also makes no representations as to your right to install any such firmware on the product. DO Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Technical specifications for 849A-ZAD25

ManufacturerAllen Bradley
CategoryTimer/Counter
Product Line849 Timing Relays
Part Number849A-ZAD25
Weight5.13 lbs (2.32 kg)
TypePneumatic, Off Delay
Voltage600 Volts AC Maximum
Line frequency60 Hertz
Time Range0.05 to 180 seconds
EnclosureNEMA Type 1
Standard Operating Temperature-17 to 40 degrees Celsius (0 to 104 degrees Fahrenheit)
Wide Operating Temperature-28 to 65 degrees Celsius (-20 to 150 degrees Fahrenheit)
Compliance/CertificationsUL 508, CSA C22.2 No. 14

The catalog number 849A-ZAD25 represents a timer/counter unit with an “off delay” feature. The 849A-ZAD25 timer is a pneumatic timer component with a 0.05 to 180 seconds time range. The unit has an input voltage rating of 110 to 120 Volts AC and an operating frequency range of 50 to 60 Hertz. This pneumatic timing relay is part of Series C and it complies with standards like the UL 508 and CSA C22.2 (No. 14) standards. The 849A-ZAD25 timer unit is UL listed and it provides visual indicators which help the users to have better device control. The 849A-ZAD25 timer unit has a maximum voltage of 600 Volts AC and it comes with a NEMA Type 1 enclosure. The unit weighs around 2 kilograms (4.5 pounds) and it features approximate dimensions of 76.2 x 182.5 x 88.1 millimeters (3 x 7.1 x 3.4 inches).

The 849A-ZAD25 timer unit has a wide operating temperature range of -28 to 65 degrees Celsius (-20 to 150 degrees Fahrenheit) and it is designed for usage for industrial applications. Even though the timer unit has a wide operating temperature range, it must be noted that the minimum temperature is based on the absence of freezing moisture or water. The 849A series of timer units offer devices with 2 basic options. The first option is an “on-delay” capability and the other one is an “off-delay” capability like the 849A-ZAD25 timer has. The “on-delay” provides a delay after the coil is energized. The “on-delay” can be converted to an “off-delay” easily and vice versa. The manufacturer provides all the necessary instructions for such conversions. The repeat accuracy of these units is +/-10% of the time setting and the minimum reset time is 75 milliseconds.