The Allen-Bradley 849A-ZOB24 Pneumatic Timing Relay is a durable industrial automation timer from the 849 series. It receives an electrical pulse that acts as the trigger for changing the electrical status of its internal switch, and instead of performing this change immediately, it waits for a user-configurable timespan before doing so. This relay is suitable for applications in hazardous or even explosive environments.

Rated 4.5 with 18 reviews

Preowned

Includes a 1-Year DO Supply warranty.

DO Supply is not an authorized distributor for Allen Bradley.

top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Available Now

Submit RFQ for 849A-ZOB24

Add more parts to quote

Description:

The Allen-Bradley 849A-ZOB24 Pneumatic Timing Relay is a durable industrial automation timer from the 849 series. It receives an electrical pulse that acts as the trigger for changing the electrical status of its internal switch, and instead of performing this change immediately, it waits for a user-configurable timespan before doing so. This relay is suitable for applications in hazardous or even explosive environments.


Preowned

Includes a 1-Year DO Supply warranty.

DO Supply is not an authorized distributor for Allen Bradley.

top legal disclaimer
disclaimer
credit cards
better business bureau

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 849A-ZOB24.
Exchange: Exchange credit for your defective unit available.
Conditions: We sell preowned surplus and refurbished parts.

To speak to a sales representative for pricing & lead time:


Rated 4.5 with 18 reviews

    Technical Specifications for 849A-ZOB24

BrandAllen-Bradley / Rockwell Automation
Series849 Timing Relays
Part Number849A-ZOB24
Product DescriptionPneumatic Timing Relay
Type of Delay On-Delay
Time Range0.05 to 180 Seconds
Visual IndicationsPresent
Type of Electrical ContactNormally Open
Maximum Voltage Applicable 120V AC
Nominal Voltage Range110 to 120V AC
Nominal Frequency50 to 60 Hz
BrandAllen-Bradley / Rockwell Automation
Series849 Timing Relays
Part Number849A-ZOB24
Product DescriptionPneumatic Timing Relay
Type of Delay On-Delay
Time Range0.05 to 180 Seconds
Visual IndicationsPresent
Type of Electrical ContactNormally Open
Maximum Voltage Applicable 120V AC
Nominal Voltage Range110 to 120V AC
Nominal Frequency50 to 60 Hz
s

About 849A-ZOB24

The Allen-Bradley 849 series 849A-ZOB24 Pneumatic Timing Relay is a type of timer switch that is specifically designed for applications where using a straight-up electrical timer instead of a pneumatic timer could be hazardous or even cause an explosion, such as in applications that involve the control and measurement of liquid gasoline levels in a tank. In this pneumatic timer, the electrical contacts are safe for hazardous environments and they are triggered by an external signal which is delayed for a specified period of time that is configured by a simple configuration screw that is located at the front of the unit. The Allen-Bradley 849A-ZOB24 Pneumatic Timing Relay uses a needle valve attached to the configuration screw for regulating the displacement of air from the internal pneumatic bellows until it reaches a point where the electrical contacts are forced to change their default status from open to closed or vice versa.



 



The Allen-Bradley 849A-ZOB24 Pneumatic Timing Relay is normally used in legacy systems and applications and mostly in industries such as chemical processing, oil and gas, and power generation applications. Any industrial application where the surrounding air can accumulate higher concentrations of explosive or flammable materials than normal is an ideal candidate for this pneumatic time relay. The Allen-Bradley 849A-ZOB24 Pneumatic Timing Relay can also be used as a spark suppression or fire and explosion prevention device that contributes significantly to worksite safety. This timing relay is also resistant to high levels of humidity and its accuracy is not compromised by temperature variations. Note that only technicians who have received special training in pneumatics should be allowed to perform maintenance on this timer. Keeping the pneumatic circuit of the timer clean is key for guaranteeing a long, trouble-free operating lifespan.



Repair Services for 849A-ZOB24

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 849A-ZOB24. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For 849A-ZOB24

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For 849A-ZOB24

Resolutions For 849A-ZOB24

About

Technical Specifications for 849A-ZOB24

BrandAllen-Bradley / Rockwell Automation
Series849 Timing Relays
Part Number849A-ZOB24
Product DescriptionPneumatic Timing Relay
Type of Delay On-Delay
Time Range0.05 to 180 Seconds
Visual IndicationsPresent
Type of Electrical ContactNormally Open
Maximum Voltage Applicable 120V AC
Nominal Voltage Range110 to 120V AC
Nominal Frequency50 to 60 Hz
BrandAllen-Bradley / Rockwell Automation
Series849 Timing Relays
Part Number849A-ZOB24
Product DescriptionPneumatic Timing Relay
Type of Delay On-Delay
Time Range0.05 to 180 Seconds
Visual IndicationsPresent
Type of Electrical ContactNormally Open
Maximum Voltage Applicable 120V AC
Nominal Voltage Range110 to 120V AC
Nominal Frequency50 to 60 Hz

About 849A-ZOB24

The Allen-Bradley 849 series 849A-ZOB24 Pneumatic Timing Relay is a type of timer switch that is specifically designed for applications where using a straight-up electrical timer instead of a pneumatic timer could be hazardous or even cause an explosion, such as in applications that involve the control and measurement of liquid gasoline levels in a tank. In this pneumatic timer, the electrical contacts are safe for hazardous environments and they are triggered by an external signal which is delayed for a specified period of time that is configured by a simple configuration screw that is located at the front of the unit. The Allen-Bradley 849A-ZOB24 Pneumatic Timing Relay uses a needle valve attached to the configuration screw for regulating the displacement of air from the internal pneumatic bellows until it reaches a point where the electrical contacts are forced to change their default status from open to closed or vice versa.



 



The Allen-Bradley 849A-ZOB24 Pneumatic Timing Relay is normally used in legacy systems and applications and mostly in industries such as chemical processing, oil and gas, and power generation applications. Any industrial application where the surrounding air can accumulate higher concentrations of explosive or flammable materials than normal is an ideal candidate for this pneumatic time relay. The Allen-Bradley 849A-ZOB24 Pneumatic Timing Relay can also be used as a spark suppression or fire and explosion prevention device that contributes significantly to worksite safety. This timing relay is also resistant to high levels of humidity and its accuracy is not compromised by temperature variations. Note that only technicians who have received special training in pneumatics should be allowed to perform maintenance on this timer. Keeping the pneumatic circuit of the timer clean is key for guaranteeing a long, trouble-free operating lifespan.



Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 849A-ZOB24. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 849A-ZOB24. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

PDF