Product image is representative; revision or series may vary. Contact us to request a specific version.
The 1489-M2C250 from Allen Bradley is a supplementary protector designed for effective circuit protection in various applications. With a continuous current rating of 25 A, it operates at a maximum AC voltage of 400 VAC and DC voltage of 96 VDC.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Supplementary Protector |
| Product Line | Bulletin 1489 |
| Part Number | 1489-M2C250 |
| Weight | 0.63 lbs (0.28 kg) |
| UPC | 885630619019 |
| Continuous Current Rating | 25 A |
| Maximum Voltage Rating (AC) | 400 VAC |
| Maximum Voltage Rating (DC) | 96 VDC |
| Pole Configuration | 2 Pole |
| Trip Curve Type | Trip Curve C |
| Minimum Frequency | 50 Hz |
| Maximum Frequency | 60 Hz |
| Short-Circuit Breaking Capacity | 15 kA |
| Dielectric Test Voltage | 2 kV |
| Bus Bar Cross-Section | 10 mm² |
| Flexible Wire Cross-Section | 25/10 mm² |
| Operating Temperature Range | -25 to 55 °C |
| Storage Temperature Range | -40 to 70 °C |
The Allen Bradley 1489-M2C250 model operates as a supplementary protector, providing essential circuit protection. Capable of managing continuous current up to 25 A, this device is suitable for use in diverse applications where power regulation is critical. It is rated for a maximum of 400 VAC in AC applications and 96 VDC for DC systems, accommodating a variety of electrical configurations.
This protector employs a 2 pole setup and utilizes Trip Curve Type C, which is ideal for environments with inductive loads. It supports operational frequencies ranging from 50 Hz to a maximum of 60 Hz. With a short-circuit breaking capacity of 15 kA, it effectively safeguards circuits against overloading and fault conditions.
The 1489-M2C250 has a dielectric test voltage of 2 kV, ensuring electrical robustness and safety during operation. For installation, it accepts bus bar cross-sections of 10 mm². Additionally, it can accommodate flexible wires up to a cross-section of 25/10 mm². Furthermore, this device functions optimally in an operating temperature range extending from -25 °C to 55 °C, while it can withstand storage temperatures of -40 °C to 70 °C, offering wide application versatility.