| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Full-Voltage Non-Reversing Motor Starter |
| Product Line | Bulletin 509 |
| Part Number | 509-B0D-XXX |
| Weight | 4.50 lbs (2.04 kg) |
| NEMA Size | Size 1 |
| Enclosure Type | Open Type |
| Phase Type | Phase 3 |
| Coil Voltage at 50 Hz | 110 VAC |
| Coil Voltage at 60 Hz | 120 VAC |
| Continuous Current | 27 A |
| Motor Power | 7.5 Hp |
| Mechanical Life | 10 Million Operations |
| Maximum Auxiliary Contacts | 8 Contacts |
| Average Pickup Time | 22 ms |
| Average Dropout Time | 14 ms |
| Power Terminal Wire Size | 14–8 AWG |
| Power Terminal Torque | 20 lb·in |
The Allen Bradley 509-B0D-XXX, part of the Bulletin 509 series, is engineered as a full-voltage motor starter that operates without reversing functionality. This device is categorized as a size 1 starter suitable for use in three-phase electrical configurations. It operates with a coil voltage of 110 VAC at 50 Hertz and 120 VAC at 60 Hertz.
The 509-B0D-XXX motor starter can continuously handle currents of up to 27 Amps and is designed for motor applications that demand a power rating of up to 7.5 horsepower. It provides a considerable mechanical lifespan, rated for approximately 10 million operations, ensuring durability and reliability in demanding environments.
This starter includes up to 8 maximum auxiliary contacts, delivering enhanced control capability. Users can expect an average pickup time of 22 milliseconds and a dropout time of around 14 milliseconds, contributing to efficient operation.
Wiring configuration for power terminals can accommodate 14 to 8 AWG wire sizes, ensuring flexibility during installation. Additionally, the power terminal torque requirement for secure connections is set at 20 lb·in. The open type enclosure allows for easy access during setup, making it a practical option for a variety of applications.