193-EC1AD

193-EC1AD

Description:

The Allen-Bradley 193-EC1AD relay is an E3 IEC solid-state overload relay. It comes with a full load current range of 1 to 5 Amps and a trip type class of 5 to 30 Amps. 

Rated 4.8 with 8 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Available Now

Submit RFQ for 193-EC1AD

Add more parts to quote

Description:

The Allen-Bradley 193-EC1AD relay is an E3 IEC solid-state overload relay. It comes with a full load current range of 1 to 5 Amps and a trip type class of 5 to 30 Amps. 



Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 193-EC1AD.
Exchange: Exchange credit for your defective unit available.

To speak to a sales representative for pricing & lead time:


Rated 4.8 with 8 reviews

    Technical Specifications for 193-EC1AD

BrandAllen-Bradley / Rockwell Automation
SeriesE1 Plus Relays
Part Number193-EC1AD
Item NameIEC Solid State Overload Relay
TypeElectronic, Current Sensing
Sub BrandE3
Full Load Current Range1 to 5 A
Trip TypeClass 5 to 30
Control Voltage11 to 25V DC
Switching CapacityNEMA B300
Temperature Rating-20 to 55 degrees Celsius
BrandAllen-Bradley / Rockwell Automation
SeriesE1 Plus Relays
Part Number193-EC1AD
Item NameIEC Solid State Overload Relay
TypeElectronic, Current Sensing
Sub BrandE3
Full Load Current Range1 to 5 A
Trip TypeClass 5 to 30
Control Voltage11 to 25V DC
Switching CapacityNEMA B300
Temperature Rating-20 to 55 degrees Celsius
s

About 193-EC1AD

The Allen-Bradley 193-EC1AD relay is an electronic motor protection overload relay that is used for protecting squirrel-cage induction motors. This 193-EC1AD overload relay is factory-programmed for 3-phase operation. However, it can also be switched to single-phase operation and this is achieved by accessing and switching to the single-phase parameter or from the default 3-phase parameter. The Allen-Bradley 193-EC1AD relay allows the users to monitor the information from different parameters via the DeviceNet network. When this 193-EC1AD overload relay is not powered on, its trip relay contact remains open. However, the trip relay contact closes within 2 to 35 seconds after powering the overload relay on and when there are no trip conditions. In addition to this trip relay, the Allen-Bradley 193-EC1AD relay also comes with various inputs and outputs.



 



The users can monitor the status of each output and input over the DeviceNet network, via Device Status Parameter 21 or in any of the output assemblies. They can also control the outputs over the network by using any of the output assemblies. The Allen-Bradley 193-EC1AD relay provides extra flexibility with the capability to perform certain control functions with its inputs and outputs via DeviceLogix. The inputs of the 193-EC1AD overload protection relay can be configured independently for trip reset, 2-speed, remote trip, and normal operation. When the users buy the 193-EC1AD overload relay, they must keep it in its shipping container before its installation. If a long time passes before this overload relay will be used, it should be stored under the proper conditions. The Allen-Bradley 193-EC1AD overload protection relay should be stored in a clean and dry location, with an ambient temperature range of -40 to 85 degrees Celsius. The relative humidity range should be between 0 and 95%.



Repair Services for 193-EC1AD

Type Lead Time Price Action
Repair Service 2-4 weeks $708.9cartAdd to Cart

Our highly skilled technicians can repair your 193-EC1AD. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For 193-EC1AD

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For 193-EC1AD

Resolutions For 193-EC1AD

About

Technical Specifications for 193-EC1AD

BrandAllen-Bradley / Rockwell Automation
SeriesE1 Plus Relays
Part Number193-EC1AD
Item NameIEC Solid State Overload Relay
TypeElectronic, Current Sensing
Sub BrandE3
Full Load Current Range1 to 5 A
Trip TypeClass 5 to 30
Control Voltage11 to 25V DC
Switching CapacityNEMA B300
Temperature Rating-20 to 55 degrees Celsius
BrandAllen-Bradley / Rockwell Automation
SeriesE1 Plus Relays
Part Number193-EC1AD
Item NameIEC Solid State Overload Relay
TypeElectronic, Current Sensing
Sub BrandE3
Full Load Current Range1 to 5 A
Trip TypeClass 5 to 30
Control Voltage11 to 25V DC
Switching CapacityNEMA B300
Temperature Rating-20 to 55 degrees Celsius

About 193-EC1AD

The Allen-Bradley 193-EC1AD relay is an electronic motor protection overload relay that is used for protecting squirrel-cage induction motors. This 193-EC1AD overload relay is factory-programmed for 3-phase operation. However, it can also be switched to single-phase operation and this is achieved by accessing and switching to the single-phase parameter or from the default 3-phase parameter. The Allen-Bradley 193-EC1AD relay allows the users to monitor the information from different parameters via the DeviceNet network. When this 193-EC1AD overload relay is not powered on, its trip relay contact remains open. However, the trip relay contact closes within 2 to 35 seconds after powering the overload relay on and when there are no trip conditions. In addition to this trip relay, the Allen-Bradley 193-EC1AD relay also comes with various inputs and outputs.



 



The users can monitor the status of each output and input over the DeviceNet network, via Device Status Parameter 21 or in any of the output assemblies. They can also control the outputs over the network by using any of the output assemblies. The Allen-Bradley 193-EC1AD relay provides extra flexibility with the capability to perform certain control functions with its inputs and outputs via DeviceLogix. The inputs of the 193-EC1AD overload protection relay can be configured independently for trip reset, 2-speed, remote trip, and normal operation. When the users buy the 193-EC1AD overload relay, they must keep it in its shipping container before its installation. If a long time passes before this overload relay will be used, it should be stored under the proper conditions. The Allen-Bradley 193-EC1AD overload protection relay should be stored in a clean and dry location, with an ambient temperature range of -40 to 85 degrees Celsius. The relative humidity range should be between 0 and 95%.



Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks $708.9cartAdd to Cart

Our highly skilled technicians can repair your 193-EC1AD. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks $708.9cartAdd to Cart

Our highly skilled technicians can repair your 193-EC1AD. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

PDF