The Allen Bradley 193-ED1DB is a solid-state overload unit within the E1 Plus Relays series meant for advanced motor control protection. It supports an adjustable current span from 3.2 A to 16 A, making it suitable for various applications as it can handle motor power ranging from 1.5 kW to 7.5 kW.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Solid-state overload unit |
| Product Line | E1 Plus Relays |
| Part Number | 193-ED1DB |
| Weight | 0.56 lbs (0.26 kg) |
| UPC | 781180127991 |
| Minimum Trip Current | 3.2 A |
| Maximum Trip Current | 16 A |
| Adjustable Current Span | 3.2–16 A |
| Adjustment Ratio | 5:1 |
| Usable Motor Power | 1.5–7.5 kW |
| Auxiliary Outputs | 1 NC + 1 NO |
| Phase-loss Sensing | ~3 s |
| Ingress Protection | IP20 |
| Max Operating Voltage | 690 V AC |
| Reset Mode | Manual |
| Thermal Response Class | Class 10 |
| Low-level Signal Capability | 17 V / 5 mA |
The 193-ED1DB from Allen Bradley is a solid-state overload unit designed for effective protection of motor applications. This unit fits within the E1 Plus Relays series and is specifically targeted towards maintaining motor safety. The trip current can be adjusted between 3.2 A and 16 A to fit specific operational needs, with an adjustment ratio set at 5:1. Rated for use with motors between 1.5 kW and 7.5 kW, this unit ensures that motors remain within safe operational parameters.
This overload unit also features both one normally closed (NC) and one normally open (NO) auxiliary output, enhancing its utility within automated control systems. In terms of resilience, the device includes phase-loss sensing with a response time of approximately 3 seconds, helping to detect issues that could lead to motor failure. It is designed to operate at a maximum voltage of 690 V AC, broadening its potential applications in differing voltage environments.
Ingress protection for the 193-ED1DB is rated at IP20, implying it is suitable for indoor use where protection from direct contact is necessary. The unit requires a manual reset after tripping, enabling straightforward maintenance procedures. With a thermal response class of Class 10, it ensures that the unit reacts appropriately to thermal conditions. Additionally, the low-level signal capability of 17 V at 5 mA enhances its compatibility with diverse control situations.