Description: The Allen-Bradley 193-EF1BKD MCS Plus solid-state overload relay belongs to the 193-EF overload relay series. This is a basic version of an overload relay and it runs on a control voltage of 110 Volts AC at 50 to 60 Hertz with full load current range of 160 to 400 Amps.
Rated 4.5 with 18 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Available Now

Submit RFQ for 193-EF1BKD

Add more parts to quote

Description:

The Allen-Bradley 193-EF1BKD MCS Plus solid-state overload relay belongs to the 193-EF overload relay series. This is a basic version of an overload relay and it runs on a control voltage of 110 Volts AC at 50 to 60 Hertz with full load current range of 160 to 400 Amps.



Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 193-EF1BKD.
Exchange: Exchange credit for your defective unit available.

To speak to a sales representative for pricing & lead time:

phone

International
919-205-4392
phone

International
919-205-4392

Rated 4.5 with 18 reviews

    Technical Specifications for 193-EF1BKD

BrandAllen-Bradley / Rockwell Automation
SeriesE1 Plus Relays
Part Number193-EF1BKD
Bulletin193-EF MCS Plus
VersionBasic
Control Voltage110V AC
Frequency50-60 Hertz
Full Load Current Range 160 to 400 A
Reset OptionManual
MountingScrew Fixing
Remote Reset Module193-RB1
Standby IndicatorYes
Status Storage Time30 minutes
Thermal Tripping Operation Time 6x/e
BrandAllen-Bradley / Rockwell Automation
SeriesE1 Plus Relays
Part Number193-EF1BKD
Bulletin193-EF MCS Plus
VersionBasic
Control Voltage110V AC
Frequency50-60 Hertz
Full Load Current Range 160 to 400 A
Reset OptionManual
MountingScrew Fixing
Remote Reset Module193-RB1
Standby IndicatorYes
Status Storage Time30 minutes
Thermal Tripping Operation Time 6x/e
s

About 193-EF1BKD

The Allen-Bradley 193-EF1BKD MCS Plus solid-state overload relay manufactured by Allen-Bradley/Rockwell Automation as part of the 193-EF overload relay series. This overload relay is a basic relay type, and it operates on a control voltage of 110 Volts AC at 50 to 60 Hertz and a full load current range of 160 to 400 Amps. When using the Bulletin 193-EF overload relays such as the 193-EF1BKD relay, and a supply voltage failure occurs, the output relay resets, and the standby indicator turns off. It stores the actual status for about 30 minutes. If the supply voltage is restored, the output relay resumes its original state. These overload relays can also be reset manually by using a reset button that protects all the functions. Additionally, the resetting can be done from any location using the 193-RB1 remote reset module.

 

Other features of the Allen-Bradley 193-EF1BKD MCS Plus solid-state overload relay include the test button for thermal overload protection. When the user presses the test button, it verifies the thermal tripping operation time at 6x/e without having to connect the motor. It allows for the resetting of all the other protection functions by manual means. The 193-EF1BKD relay is mounted by screw fixing, and the mounting position is optional. For correct device commissioning and installation, the overload relay comes with operating instructions enclosed with it. Other devices in the Bulletin 193-EF series such as the 193-EF1A and 193-EF2A relays require 193 HD when setting the rated current at 0.5 to 20 Amps. The motor supply cables are wound twice around the current transformer to double the rated motor current.

Repair Services for 193-EF1BKD

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 193-EF1BKD. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For 193-EF1BKD

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For 193-EF1BKD

Resolutions For 193-EF1BKD

Technical Specifications
BrandAllen-Bradley / Rockwell Automation
SeriesE1 Plus Relays
Part Number193-EF1BKD
Bulletin193-EF MCS Plus
VersionBasic
Control Voltage110V AC
Frequency50-60 Hertz
Full Load Current Range 160 to 400 A
Reset OptionManual
MountingScrew Fixing
Remote Reset Module193-RB1
Standby IndicatorYes
Status Storage Time30 minutes
Thermal Tripping Operation Time 6x/e
BrandAllen-Bradley / Rockwell Automation
SeriesE1 Plus Relays
Part Number193-EF1BKD
Bulletin193-EF MCS Plus
VersionBasic
Control Voltage110V AC
Frequency50-60 Hertz
Full Load Current Range 160 to 400 A
Reset OptionManual
MountingScrew Fixing
Remote Reset Module193-RB1
Standby IndicatorYes
Status Storage Time30 minutes
Thermal Tripping Operation Time 6x/e
About

The Allen-Bradley 193-EF1BKD MCS Plus solid-state overload relay manufactured by Allen-Bradley/Rockwell Automation as part of the 193-EF overload relay series. This overload relay is a basic relay type, and it operates on a control voltage of 110 Volts AC at 50 to 60 Hertz and a full load current range of 160 to 400 Amps. When using the Bulletin 193-EF overload relays such as the 193-EF1BKD relay, and a supply voltage failure occurs, the output relay resets, and the standby indicator turns off. It stores the actual status for about 30 minutes. If the supply voltage is restored, the output relay resumes its original state. These overload relays can also be reset manually by using a reset button that protects all the functions. Additionally, the resetting can be done from any location using the 193-RB1 remote reset module.

 

Other features of the Allen-Bradley 193-EF1BKD MCS Plus solid-state overload relay include the test button for thermal overload protection. When the user presses the test button, it verifies the thermal tripping operation time at 6x/e without having to connect the motor. It allows for the resetting of all the other protection functions by manual means. The 193-EF1BKD relay is mounted by screw fixing, and the mounting position is optional. For correct device commissioning and installation, the overload relay comes with operating instructions enclosed with it. Other devices in the Bulletin 193-EF series such as the 193-EF1A and 193-EF2A relays require 193 HD when setting the rated current at 0.5 to 20 Amps. The motor supply cables are wound twice around the current transformer to double the rated motor current.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 193-EF1BKD. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 193-EF1BKD. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

PDF