Product image is representative; revision or series may vary. Contact us to request a specific version.
The 1408-TR1A-ENT transducer device is a PowerMonitor 1000 system transducer from Allen-Bradley. It is a voltage and current transducer which works with 120 to 240 Volts AC or 125 to 250 Volts DC control power. The 1408-TR1A-ENT transducer comes with an integrated Ethernet port.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product type | Voltage and current transducer |
| Product Line | PowerMonitor 1000 |
| Part Number | 1408-TR1A-ENT |
| Weight | 3.00 lbs (1.36 kg) |
| Control power | 120 / 240 Volts AC, 125-250 Volts DC |
| AC control power range | 85 to 264 Volts AC |
| DC control power range | 125 to 250 Volts DC |
| Maximum control power | 4 VA |
| Communication | Ethernet |
| Operating temperature | 14 to 140 degrees Fahrenheit |
| Wire size | 0.34 to 2.5 mm2 |
| Maximum wire torquq | 7 lb-in |
| Storage temperature | â40 and 185 degrees Fahrenheit |
| UPC | 10662074663566 |
The 1408-TR1A-ENT transducer is a PowerMonitor 1000 transducer from Allen-Bradley. It is a voltage and current transducer which works with 120 to 240 Volts AC or 125 to 250 Volts DC control power. The 1408-TR1A-ENT transducer comes with an integrated Ethernet port. Devices from the PowerMonitor product line are intended for applications that require power and energy metering such as industrial control panels and distribution centers. Voltage and current levels are measured and communicated to applications such as RSPowerPlus as RSPower applications. The single-phase or 3-phase consumer electrical system connects to the power monitor. This connection can be direct or it can be through a transformer.
The maximum input power to the 1408-TR1A-ENT transducer can be 4 VA. The range of control power input voltages is from 85 to 264 Volts AC and 125 to 250 Volts DC. The dielectric withstand threshold for control power on the 1408-TR1A-ENT transducer is 2500 Volts, and the threshold for the current and voltage inputs is 2500 Volts. The working temperature range for the 1408-TR1A-ENT transducer is 14 to 140 degrees Fahrenheit. For device storage, Allen-Bradley recommends an environment that is free of corrosive elements such as dust and vapors with a temperature range between –40 and 185 degrees Fahrenheit. Only copper wire should be used for terminations on the 1408-TR1A-ENT transducer. The size of the copper wire should be between 0.34 to 2.5 mm2. The torque on the wire should not exceed 7 pounds on an inch.