140G-G-EA2R1A

|

The catalog number 140G-G-EA2R1A identifies an auxiliary contact block designed and built by Allen-Bradley in order to provide additional signals for the remote monitoring of the open or closed condition of 140G circuit breakers and switches. It is designed to be compatible with Frames G, H, I, and J of the 140G series, and is composed of 2 auxiliary contacts and 1 alarm contact, both in Form C. It has a rated voltage of 250 Volts AC, a rated current of 6 Amps at 250 Volts AC and is suitable for installation with AWG 20 (0.5 millimeters) cables. For DC operation, the rated operational current varies between 0.5 Amps at 110 Volts DC and 0.3 Amps at 250 Volts DC.

Ships Fri, May 23.
In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with DO Supply's 2-year warranty.
Learn more
  • We sell industrial automation parts backed by our 2-year DO Supply Warranty.

  • Same-day domestic and expedited international shipping with UPS, FedEx, DHL, and more.

  • AMEX, Visa, MasterCard, Discover, wire transfer, and more, plus flexible payment plans.

  • Repair and exchange services for all existing automation products.

  • Reseller Options

    Drop shipping, blind shipping, and account shipping with no extra fees.

Technical specifications for 140G-G-EA2R1A

BrandAllen-Bradley / Rockwell Automation
Series140G MCB
Part Number140G-G-EA2R1A
Type of componentAuxiliary contact block
Compatible with framesG, H, I and J
Number of auxiliary contacts2
Number of alarm contacts1
Rated Voltage 250V
Rated Current6 A
Wire size20 AWG (0.5mm)
Pigtail wire lenght 1 meter (39 in.)
Rockwell Disclaimer: The product is used surplus. DO Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because DO Supply is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. DO Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. DO Supply also makes no representations as to your right to install any such firmware on the product. DO Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

The catalog number 140G-G-EA2R1A identifies an auxiliary contact block that has been designed and built by Allen-Bradley in order to provide additional signals for the remote monitoring of the open or closed condition of 140G series circuit breakers and switches. It is designed to be compatible with Frames G, H, I, and J of the 140G series, and it is composed of 2 auxiliary contacts and 1 alarm contact, both in Form C. It has a rated voltage of 250 Volts AC at a rated current of 6 Amps and it is suitable for installation with AWG 20 (0.5 millimeters) cables. For DC operation, the rated operational current varies between 0.5 Amps at 110 Volts DC and 0.3 Amps at 250 Volts DC.

The Allen-Bradley 140G-G-EA2R1A auxiliary contact block is easily installed by removing the main device cover and accessing the pockets on the right side within with the snap-in mounting provisions. It comes supplied with 1-meter (39-inch) pigtail wiring, with markings in each terminal wire. The Allen-Bradley 140G-G-EA2R1A auxiliary contact block is used to indicate the ON/OFF status of the main device. The alarm contacts (AL) indicate the trip status of the MCCB (Molded Case Circuit Breaker). The alarm can be tripped by pressing the test button on the molded case circuit breaker or it can be initiated due to overcurrent, short circuit, residual currents, shunts, or undervoltage situations. Some external functions that can be triggered by the use of auxiliary contact blocks such as the Allen-Bradley 140G-G-EA2R1A auxiliary contact block are audible alarm sounds, signaling a visual alarm with a light, initiating a machine process, and engaging a backup power source.