140G-G2C3-C40
Preowned
Includes a 1-Year DO Supply warranty.
DO Supply is not an authorized distributor for Allen Bradley.
Preowned
Includes a 1-Year DO Supply warranty.
DO Supply is not an authorized distributor for Allen Bradley.
Warranty: | 1 year DO Supply Warranty Included |
Shipping: | Worldwide shipping via UPS, DHL, and TNT |
Repairs: | We offer repair service for the 140G-G2C3-C40. |
Exchange: | Exchange credit for your defective unit available. |
Conditions: | We sell preowned surplus and refurbished parts. |
Manufacturer | Eaton Cutler-Hammer |
Brand | Eaton Cutler-Hammer |
Part Number/Catalog No. | 140G-G2C3-C40 |
Product Type | Molded Case Circuit Breaker |
Frame | G |
Amps | 125 |
Interrupting Rating | 25 kA |
Protection Type | Fixed Thermal/ Fixed Magnetic |
Current Range | 40 A |
Rated Insulation Voltage | 800 V |
Rated Impulse Withstand Voltage | 8 kV |
Weight | 2.42 lb |
Thermal Trip | 40 A |
Magnetic Trip | 500 A |
Manufacturer | Eaton Cutler-Hammer |
Brand | Eaton Cutler-Hammer |
Part Number/Catalog No. | 140G-G2C3-C40 |
Product Type | Molded Case Circuit Breaker |
Frame | G |
Amps | 125 |
Interrupting Rating | 25 kA |
Protection Type | Fixed Thermal/ Fixed Magnetic |
Current Range | 40 A |
Rated Insulation Voltage | 800 V |
Rated Impulse Withstand Voltage | 8 kV |
Weight | 2.42 lb |
Thermal Trip | 40 A |
Magnetic Trip | 500 A |
The Allen-Bradley 140G-G2C3-C40 molded case circuit breaker is a thermal-magnetic circuit breaker designed to provide thermal overcurrent and short-circuit protection to industrial control panel applications. The 140G circuit breakers are sized per table 450-152 of the NEC code, and they come in a very compact package with field-installable accessories that make them ideal for nearly all industrial environmental conditions. The 140G-G2C3-C40 circuit breaker is rated at 690 Volts AC voltage per the IEC standards (600 Volts AC voltage per the UL/CSA standards) and it has a 125 Amps current rating. The 140G-G2C3-C40 circuit breaker has a 25,000 Amps (25 KA) interrupting rating and a rated insulation voltage of 800 Volts AC.
The 140G-G2C3-C40 circuit breaker has a magnet trip rating of 500 Amps and a 40 Amps thermal rating. It has 8 kilovolts of AC voltage. The 140G-G2C3-C40 circuit breaker has a trip unit with fixed thermal and fixed magnetic trip ratings, and this trip unit provides fast-acting trip action using a high current-heated bimetallic element and an electromagnetic coil in series with the line current. The 140G-G2C3-C40 circuit breaker has a rotary switch, which opens and closes the circuit breaker’s contact, and it also helps to show the breaker’s position. The 140G-G2C3-C40 circuit breaker has a 3-pole wiring configuration, and bolt-on line and load terminals. It has slots for internal accessories (such as the auxiliary alarm, auxiliary contact, shunt trip, shunt close, under-voltage release, and the current transformer), and a pig-tail wiring termination for these accessories. The 140G-G2C3-C40 circuit breaker has an operating limit of 40 degrees Celsius without de-rating, and it is rated 80% efficient at this temperature. It has an average weight of 1.1 kilograms, and approximate dimensions of 76.2 x 70 x 130 millimeters.
The Allen-Bradley 140G-G2C3-C40 Molded Case Circuit Breaker has a G Frame and 125 Amps. It also has a 25 kA Interrupting Rating and 3 Poles.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 140G-G2C3-C40. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Please refer to the manual for more information about the 140G-G2C3-C40 such as the wiring diagrams, data sheets and migration or obsolescence details.
Revision Part # | Also Known as | Availability |
140G-G2C3-C40 Ser A
|
140G-G2C3-C40/A, Series A, Rev A | Request Quote |
Size | |
Input Type | |
Panel Cutout Height | in mm |
Panel Cutout Width | in mm |
Terminal Height | in mm |
Terminal Width | in mm |
Terminal Overall Depth | in mm |
Terminal Mounted Depth | in mm |
Manufacturer | Eaton Cutler-Hammer |
Brand | Eaton Cutler-Hammer |
Part Number/Catalog No. | 140G-G2C3-C40 |
Product Type | Molded Case Circuit Breaker |
Frame | G |
Amps | 125 |
Interrupting Rating | 25 kA |
Protection Type | Fixed Thermal/ Fixed Magnetic |
Current Range | 40 A |
Rated Insulation Voltage | 800 V |
Rated Impulse Withstand Voltage | 8 kV |
Weight | 2.42 lb |
Thermal Trip | 40 A |
Magnetic Trip | 500 A |
Manufacturer | Eaton Cutler-Hammer |
Brand | Eaton Cutler-Hammer |
Part Number/Catalog No. | 140G-G2C3-C40 |
Product Type | Molded Case Circuit Breaker |
Frame | G |
Amps | 125 |
Interrupting Rating | 25 kA |
Protection Type | Fixed Thermal/ Fixed Magnetic |
Current Range | 40 A |
Rated Insulation Voltage | 800 V |
Rated Impulse Withstand Voltage | 8 kV |
Weight | 2.42 lb |
Thermal Trip | 40 A |
Magnetic Trip | 500 A |
The Allen-Bradley 140G-G2C3-C40 molded case circuit breaker is a thermal-magnetic circuit breaker designed to provide thermal overcurrent and short-circuit protection to industrial control panel applications. The 140G circuit breakers are sized per table 450-152 of the NEC code, and they come in a very compact package with field-installable accessories that make them ideal for nearly all industrial environmental conditions. The 140G-G2C3-C40 circuit breaker is rated at 690 Volts AC voltage per the IEC standards (600 Volts AC voltage per the UL/CSA standards) and it has a 125 Amps current rating. The 140G-G2C3-C40 circuit breaker has a 25,000 Amps (25 KA) interrupting rating and a rated insulation voltage of 800 Volts AC.
The 140G-G2C3-C40 circuit breaker has a magnet trip rating of 500 Amps and a 40 Amps thermal rating. It has 8 kilovolts of AC voltage. The 140G-G2C3-C40 circuit breaker has a trip unit with fixed thermal and fixed magnetic trip ratings, and this trip unit provides fast-acting trip action using a high current-heated bimetallic element and an electromagnetic coil in series with the line current. The 140G-G2C3-C40 circuit breaker has a rotary switch, which opens and closes the circuit breaker’s contact, and it also helps to show the breaker’s position. The 140G-G2C3-C40 circuit breaker has a 3-pole wiring configuration, and bolt-on line and load terminals. It has slots for internal accessories (such as the auxiliary alarm, auxiliary contact, shunt trip, shunt close, under-voltage release, and the current transformer), and a pig-tail wiring termination for these accessories. The 140G-G2C3-C40 circuit breaker has an operating limit of 40 degrees Celsius without de-rating, and it is rated 80% efficient at this temperature. It has an average weight of 1.1 kilograms, and approximate dimensions of 76.2 x 70 x 130 millimeters.
The Allen-Bradley 140G-G2C3-C40 Molded Case Circuit Breaker has a G Frame and 125 Amps. It also has a 25 kA Interrupting Rating and 3 Poles.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 140G-G2C3-C40. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 140G-G2C3-C40. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Please refer to the manual for more information about the 140G-G2C3-C40 such as the wiring diagrams, data sheets and migration or obsolescence details.
Revision Part # | Also Known as | Availability |
140G-G2C3-C40 Ser A
|
140G-G2C3-C40/A, Series A, Rev A | Request Quote |