The Allen-Bradley/Rockwell Automation 140G-G2C3-D10 circuit breaker is a molded case circuit breaker from the Bulletin 140G series. It is a fixed thermal and a fixed magnetic type of molded case circuit breaker. The 140G-G2C3-D10 molded case circuit breaker supports a thermal trip rating of 100 Amps and a magnetic trip rating of 1000 Amps. This circuit breaker can operate safely in non-hazardous industrial environments with ambient temperatures between 0 and 40 degrees Celsius. The 140G-G2C3-D10 molded case circuit breaker comes with 3 poles and its frame is a Size G frame.
We sell industrial automation parts backed by our 2-year DO Supply Warranty.
Same-day domestic and expedited international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, and more, plus flexible payment plans.
Repair and exchange services for all existing automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
Manufacturer | Eaton Cutler-Hammer |
---|---|
Brand | Eaton Cutler-Hammer |
Part Number/Catalog No. | 140G-G2C3-D10 |
Product Type | Molded Case Circuit Breaker |
Frame | G |
Amps | 125 |
Interrupting Rating | 25 kA |
Protection Type | Fixed Thermal/ Fixed Magnetic |
Current Range | 100 A |
Rated Insulation Voltage | 800 V |
Rated Impulse Withstand Voltage | 8 kV |
Weight | 2.42 lb |
Thermal Trip | 100 A |
Magnetic Trip | 1000 A |
The Allen-Bradley 140G-G2C3-D10 circuit breaker is a 3-pole circuit breaker that comes in the G series of circuit breakers. The main detection mechanism of the breaker is a fixed thermal and magnetic mechanism. This mechanism uses heat and magnets to detect any kind of anomalies in the current, for example, a short-circuit current. With the installation of the Allen-Bradley 140G-G2C3-D10 3-pole circuit breaker in a machine system, operations are safe. The connected equipment and conduits will not suffer damage from short-circuit currents. The breaker has 1 main function that starts with the detection of current and then the performance of a tripping action that will impede the current flow through the conduits. This breaker is commonly used as a control panel switch as well.
The Allen-Bradley 140G-G2C3-D10 3-pole circuit breaker can be put back into operations immediately after the clearing of the fault that caused the interruption, and this is one of the advantages of circuit breakers of fuses. Fuses can be used only once, whereas circuit breakers can work multiple times. The Allen-Bradley 140G-G2C3-D10 3-pole circuit breaker features an interrupting capacity of 25 kA tested at 480 Volts AC voltage. It also comes with a rating of 125 Amps and a rated current of 100 Amps. The users need to consider 2 important facts before installing the breaker. The first thing is the current rating of the unit that is going to be protected by the breaker, along with the voltage and short-circuit currents that are available. The second thing to consider is that the environment where the breaker is going to be installed may affect its performance since one of its detection mechanisms is heat-related.
Revision Part # | Also known as | |
---|---|---|
140G-G2C3-D10 Ser A | 140G-G2C3-D10/A, Series A, Rev A | Request a quote |
Don't see your particular revision? Contact us now. |
The Allen-Bradley 140G-G2C3-D10 Molded Case Circuit Breaker has a G Frame and 125 Amps. It also has a 25 kA Interrupting Rating and 3 Poles.