Product image is representative; revision or series may vary. Contact us to request a specific version.
The Allen-Bradley 140G-G3C3-C60 circuit breaker is a molded case circuit breaker that can supply a control panel with fixed thermal protection and fixed magnetic protection. It is a member of the Allen-Bradley Bulletin 140G series of circuit breakers. The 140G-G3C3-C60 molded case circuit breaker comes with 3 poles, a Size G frame, and an 80% continuous load rating. The thermal trip rating of this circuit breaker is 60 Amps and the magnetic trip rating is 600 Amps. The 140G-G3C3-C60 molded case circuit breaker also supports an interrupting rating of 35 kiloamps.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Molded Case Circuit Breaker |
| Product Line | 140G MCB |
| Part Number | 140G-G3C3-C60 |
| Weight | 3.00 lbs (1.36 kg) |
| Frame | G |
| Amps | 125 |
| Interrupting Rating | 35 kA |
| Protection Type | Fixed Thermal/ Fixed Magnetic |
| Current Range | 60 A |
| Rated Insulation Voltage | 800 V |
| Rated Impulse Withstand Voltage | 8 kV |
| Thermal Trip | 60 A |
| Magnetic Trip | 600 A |
The Allen-Bradley 140G-G3C3-C60 circuit breaker is a molded case circuit breaker (MCCB) that features thermal and magnetic trip mechanisms. It is included in the Allen-Bradley 140G series of molded-case circuit breakers. This mechanism enables the breaker to detect abnormal currents and perform an interrupting action that will stop the current flow from causing further damages. Â This breaker can be applied as the main breaker and as a feeder circuit breaker, depending on the application requirements. The Allen-Bradley 140G-G3C3-C60 molded case circuit breaker (MCCB) comes with 3 poles and a rated current of 125 Amps. The interrupting capacity of the breaker is 35 kA (based on 480 Volts AC) and it comes with a current range of 60 Amps. One of the attractive features of the breaker is that it comes with high interrupting and breaking capacities AND at the same time provides saves space and comes manufactured in anti-corrosion and anti-condensation materials.
The Allen-Bradley 140G-G3C3-C60 molded case circuit breaker (MCCB) is composed of more than 1 accessory. Among its external parts, it has standard end cap terminals, multi-cable terminal lugs, and extended phase barriers. It also has internal accessories such as auxiliary and alarm contacts, shunt trips, and a UV relay. When installing the Allen-Bradley 140G-G3C3-C60 molded case circuit breaker (MCCB), cables rated for operation temperatures between 50 and 60 degrees Celsius are recommended and the breaker can be mounted in different positions without altering its general functioning, but it is necessary to know local plant regulations before mounting the breaker. This unit is sensitive to extremely high temperatures and its performance might be affected by excessive heat.
| Revision Part # | Also known as | |
|---|---|---|
| 140G-G3C3-C60 Ser A | 140G-G3C3-C60/A, Series A, Rev A | |
| Don't see your particular revision? Contact us now. | ||
The Allen-Bradley 140G-G3C3-C60 Molded Case Circuit Breaker has a G Frame and 125 Amps. It also has a 35 kA Interrupting Rating and 3 Poles.