The 140G-G6C3-C20 circuit breaker is a fixed thermal and fixed magnetic circuit breaker with a molded case. It has been designed and manufactured by Allen-Bradley/Rockwell Automation in the Bulletin 140G series. The 140G-G6C3-C20 fixed thermal and fixed magnetic circuit breaker operates with a thermal trip rating of 20 Amps and a magnetic trip rating of 500 Amps. It can be mounted vertically or horizontally as needed and it can be mounted inside an optional cabinet for protection from water and dust. The 140G-G6C3-C20 fixed thermal and fixed magnetic circuit breaker is equipped with a Size G frame and 3 poles.
We sell industrial automation parts backed by our 2-year DO Supply Warranty.
Same-day domestic and expedited international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, and more, plus flexible payment plans.
Repair and exchange services for all existing automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
Manufacturer | Eaton Cutler-Hammer |
---|---|
Brand | Eaton Cutler-Hammer |
Part Number/Catalog No. | 140G-G6C3-C20 |
Product Type | Molded Case Circuit Breaker |
Frame | G |
Amps | 125 |
Interrupting Rating | 65 kA |
Protection Type | Fixed Thermal/ Fixed Magnetic |
Current Range | 20 A |
Rated Insulation Voltage | 800 V |
Rated Impulse Withstand Voltage | 8 kV |
Weight | 2.42 lb |
Thermal Trip | 20 A |
Magnetic Trip | 500 A |
The Allen-Bradley 140G-G6C3-C20 thermal and magnetic circuit breaker comes embedded in a protective case to provide protection against contact with different kinds of particles. It has been designed and distributed by Allen-Bradley /Rockwell Automation to protect electric circuits and conduits. This breaker belongs to the Allen-Bradley 140G series. The Allen-Bradley/Rockwell Automation 140G-G6C3-C20 thermal and magnetic circuit breaker is mainly used to interrupt the power to different wirings when the current flow exceeds safe levels or when it becomes a dangerous current for the conduit or the equipment attached. Short-circuit currents can cause permanent damage to equipment, panels, and conduits, and it can even cause a fire or create a dangerous condition for the users around it.
The Allen-Bradley/Rockwell Automation 140G-G6C3-C20 thermal and magnetic circuit breaker has a small size that helps to save space and it has a long lifespan that avoids high replacement costs. The thermal detection mechanism consists of metal bars that get heated up by the same current that flows into the conduits and the magnetic mechanism employs a magnet that detects short-circuit currents. These 2 mechanisms are combined with 3 poles that perform the opening/closing actions. The Allen-Bradley/Rockwell Automation 140G-G6C3-C20 thermal and magnetic circuit breaker has a current range of 20 Amps and an interrupting capacity of 65 kA. The breaker can operate at 80% of its current range when it is installed properly. There are no big requirements for the installation of the circuit breaker, it can be mounted in any position and the cables used are those that are rated for operations at 75 degrees Celsius. Before installing the breaker, its specifications need to be compatible with the current rating of the application.
Revision Part # | Also known as | |
---|---|---|
140G-G6C3-C20 Ser A | 140G-G6C3-C20/A, Series A, Rev A | Request a quote |
Don't see your particular revision? Contact us now. |
The Allen-Bradley 140G-G6C3-C20 Molded Case Circuit Breaker has a G Frame and 125 Amps. It also has a 65 kA Interrupting Rating and 3 Poles.