140G-G6C3-D12
Preowned
Includes a 1-Year DO Supply warranty.
DO Supply is not an authorized distributor for Allen Bradley.
Preowned
Includes a 1-Year DO Supply warranty.
DO Supply is not an authorized distributor for Allen Bradley.
Warranty: | 1 year DO Supply Warranty Included |
Shipping: | Worldwide shipping via UPS, DHL, and TNT |
Repairs: | We offer repair service for the 140G-G6C3-D12. |
Exchange: | Exchange credit for your defective unit available. |
Conditions: | We sell preowned surplus and refurbished parts. |
Manufacturer | Eaton Cutler-Hammer |
Brand | Eaton Cutler-Hammer |
Part Number/Catalog No. | 140G-G6C3-D12 |
Product Type | Molded Case Circuit Breaker |
Frame | G |
Amps | 125 |
Interrupting Rating | 65 kA |
Protection Type | Fixed Thermal/ Fixed Magnetic |
Current Range | 125 A |
Rated Insulation Voltage | 800 V |
Rated Impulse Withstand Voltage | 8 kV |
Weight | 2.42 lb |
Thermal Trip | 125 A |
Magnetic Trip | 1250 A |
Manufacturer | Eaton Cutler-Hammer |
Brand | Eaton Cutler-Hammer |
Part Number/Catalog No. | 140G-G6C3-D12 |
Product Type | Molded Case Circuit Breaker |
Frame | G |
Amps | 125 |
Interrupting Rating | 65 kA |
Protection Type | Fixed Thermal/ Fixed Magnetic |
Current Range | 125 A |
Rated Insulation Voltage | 800 V |
Rated Impulse Withstand Voltage | 8 kV |
Weight | 2.42 lb |
Thermal Trip | 125 A |
Magnetic Trip | 1250 A |
The 140G-G6C3-D12 fixed thermal-magnetic circuit breaker is a molded case circuit breaker that belongs to the Allen-Bradley 140G molded case circuit breaker series and that is designed to provide full short-circuit and thermal current overload protection to a wide range of control panel applications. This device belongs to the G Frame circuit breaker family which is rated for HACR and reverse feed use, and they come in a very compact package with field-installable accessories that help simplify the configuration process and reduced maintenance costs. The 140G-G6C3-D12 circuit breaker has a continuous current rating of 125 Amps and it is, therefore, suitable for main disconnect/feeder circuits or branch circuits with sized ratings of less than or equal to 125 Amps. It can be used for circuits with ratings of up to 600 Volts AC (per the UL standards).
The 140G-G6C3-D12 circuit breaker has a fixed thermal trip rating of 120 Amps and a fixed magnetic trip rating of 1250 Amps. It has a rated insulation voltage of 800 Volts, with an 8000 Volts maximum impulse withstand rating and a mechanical lifespan of up to 24,000 operations. The 140G-G6C3-D12 circuit breaker’s protection unit (trip unit) consists of a fixed heater element connected to a lever device that provides thermal trip actions in prolonged large current conditions, and an electromagnet connected in a series with a line current that provides an instantaneous trip action when the load exceeds the designated value. The 140G-G6C3-D12 circuit breaker is a 3-pole circuit breaker with standard bolt-on terminals (load and line terminals), and a standard pig-tail wiring terminal for the termination of optional internal accessories. The 140G-G6C3-D12 circuit breaker has flexible mounting configuration and it is 80% rated at a 40 degrees Celsius maximum ambient temperature.
The Allen-Bradley 140G-G6C3-D12 Molded Case Circuit Breaker has a G Frame and 125 Amps. It also has a 65 kA Interrupting Rating and 3 Poles.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 140G-G6C3-D12. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Please refer to the manual for more information about the 140G-G6C3-D12 such as the wiring diagrams, data sheets and migration or obsolescence details.
Revision Part # | Also Known as | Availability |
140G-G6C3-D12 Ser A
|
140G-G6C3-D12/A, Series A, Rev A | Request Quote |
Size | |
Input Type | |
Panel Cutout Height | in mm |
Panel Cutout Width | in mm |
Terminal Height | in mm |
Terminal Width | in mm |
Terminal Overall Depth | in mm |
Terminal Mounted Depth | in mm |
Manufacturer | Eaton Cutler-Hammer |
Brand | Eaton Cutler-Hammer |
Part Number/Catalog No. | 140G-G6C3-D12 |
Product Type | Molded Case Circuit Breaker |
Frame | G |
Amps | 125 |
Interrupting Rating | 65 kA |
Protection Type | Fixed Thermal/ Fixed Magnetic |
Current Range | 125 A |
Rated Insulation Voltage | 800 V |
Rated Impulse Withstand Voltage | 8 kV |
Weight | 2.42 lb |
Thermal Trip | 125 A |
Magnetic Trip | 1250 A |
Manufacturer | Eaton Cutler-Hammer |
Brand | Eaton Cutler-Hammer |
Part Number/Catalog No. | 140G-G6C3-D12 |
Product Type | Molded Case Circuit Breaker |
Frame | G |
Amps | 125 |
Interrupting Rating | 65 kA |
Protection Type | Fixed Thermal/ Fixed Magnetic |
Current Range | 125 A |
Rated Insulation Voltage | 800 V |
Rated Impulse Withstand Voltage | 8 kV |
Weight | 2.42 lb |
Thermal Trip | 125 A |
Magnetic Trip | 1250 A |
The 140G-G6C3-D12 fixed thermal-magnetic circuit breaker is a molded case circuit breaker that belongs to the Allen-Bradley 140G molded case circuit breaker series and that is designed to provide full short-circuit and thermal current overload protection to a wide range of control panel applications. This device belongs to the G Frame circuit breaker family which is rated for HACR and reverse feed use, and they come in a very compact package with field-installable accessories that help simplify the configuration process and reduced maintenance costs. The 140G-G6C3-D12 circuit breaker has a continuous current rating of 125 Amps and it is, therefore, suitable for main disconnect/feeder circuits or branch circuits with sized ratings of less than or equal to 125 Amps. It can be used for circuits with ratings of up to 600 Volts AC (per the UL standards).
The 140G-G6C3-D12 circuit breaker has a fixed thermal trip rating of 120 Amps and a fixed magnetic trip rating of 1250 Amps. It has a rated insulation voltage of 800 Volts, with an 8000 Volts maximum impulse withstand rating and a mechanical lifespan of up to 24,000 operations. The 140G-G6C3-D12 circuit breaker’s protection unit (trip unit) consists of a fixed heater element connected to a lever device that provides thermal trip actions in prolonged large current conditions, and an electromagnet connected in a series with a line current that provides an instantaneous trip action when the load exceeds the designated value. The 140G-G6C3-D12 circuit breaker is a 3-pole circuit breaker with standard bolt-on terminals (load and line terminals), and a standard pig-tail wiring terminal for the termination of optional internal accessories. The 140G-G6C3-D12 circuit breaker has flexible mounting configuration and it is 80% rated at a 40 degrees Celsius maximum ambient temperature.
The Allen-Bradley 140G-G6C3-D12 Molded Case Circuit Breaker has a G Frame and 125 Amps. It also has a 65 kA Interrupting Rating and 3 Poles.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 140G-G6C3-D12. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 140G-G6C3-D12. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Please refer to the manual for more information about the 140G-G6C3-D12 such as the wiring diagrams, data sheets and migration or obsolescence details.
Revision Part # | Also Known as | Availability |
140G-G6C3-D12 Ser A
|
140G-G6C3-D12/A, Series A, Rev A | Request Quote |