140G-H2C3-C50 | Allen Bradley PLC 140G MCB

140G-H2C3-C50

140G-H2C3-C50

Revisions: Ser A 
Description: The 140G-H2C3-C50 thermal/magnetic circuit breaker has been manufactured by Allen-Bradley/Rockwell Automation as a member of the Bulletin 140G series. It is a fixed thermal and fixed magnetic type of circuit breaker with a fixed thermal trip rating of 50 Amps and a fixed magnetic trip rating of 500 Amps. The 140G-H2C3-C50 thermal/magnetic circuit breaker can be used as the main circuit protector for an industrial control panel or it can be used as a branch circuit protection device instead. This device is easy to mount because it can be mounted horizontally or vertically, it can be mounted on a DIN Rail, and it can be mounted inside a cabinet if necessary. The 140G-H2C3-C50 thermal/magnetic circuit breaker is designed with 3 poles.
Rated 4.5 with 12 reviews

DO Supply is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply. Product comes with DO Supply's 1-year warranty

Rockwell Disclaimer: The product is used surplus. DO Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because DO Supply is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. DO Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. DO Supply also makes no representations as to your right to install any such firmware on the product. DO Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Rockwell Disclaimer: The product is used surplus. DO Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because DO Supply is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. DO Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. DO Supply also makes no representations as to your right to install any such firmware on the product. DO Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.


credit cards accepted
better business bureau

Available Now

Submit RFQ for 140G-H2C3-C50

Add more parts to quote

Description: The 140G-H2C3-C50 thermal/magnetic circuit breaker has been manufactured by Allen-Bradley/Rockwell Automation as a member of the Bulletin 140G series. It is a fixed thermal and fixed magnetic type of circuit breaker with a fixed thermal trip rating of 50 Amps and a fixed magnetic trip rating of 500 Amps. The 140G-H2C3-C50 thermal/magnetic circuit breaker can be used as the main circuit protector for an industrial control panel or it can be used as a branch circuit protection device instead. This device is easy to mount because it can be mounted horizontally or vertically, it can be mounted on a DIN Rail, and it can be mounted inside a cabinet if necessary. The 140G-H2C3-C50 thermal/magnetic circuit breaker is designed with 3 poles.

DO Supply is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply. Product comes with DO Supply's 1-year warranty

Rockwell Disclaimer: The product is used surplus. DO Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because DO Supply is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. DO Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. DO Supply also makes no representations as to your right to install any such firmware on the product. DO Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

disclaimer
credit cards
better business bureau
Revisions: Ser A 

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via UPS, DHL, and TNT
Repairs: We offer repair service for the 140G-H2C3-C50.
Exchange: Exchange credit for your defective unit available.
Conditions: We sell preowned surplus and refurbished parts.

To speak to a sales representative for pricing & lead time:


Rated 4.5 with 12 reviews

    Technical Specifications for 140G-H2C3-C50

ManufacturerEaton Cutler-Hammer
BrandEaton Cutler-Hammer
Part Number/Catalog No.140G-H2C3-C50
Product TypeMolded Case Circuit Breaker
FrameH
Amps125
Interrupting Rating25 kA
Protection TypeFixed Thermal/ Fixed Magnetic
Current Range50 A
Rated Insulation Voltage1000 V
Rated Impulse Withstand Voltage8 kV
Weight2.65 lb
Mechanical Life240 Operations/hr.
Electrical Life120 Operations/ hr.
ManufacturerEaton Cutler-Hammer
BrandEaton Cutler-Hammer
Part Number/Catalog No.140G-H2C3-C50
Product TypeMolded Case Circuit Breaker
FrameH
Amps125
Interrupting Rating25 kA
Protection TypeFixed Thermal/ Fixed Magnetic
Current Range50 A
Rated Insulation Voltage1000 V
Rated Impulse Withstand Voltage8 kV
Weight2.65 lb
Mechanical Life240 Operations/hr.
Electrical Life120 Operations/ hr.
s

About 140G-H2C3-C50

The 140G-H2C3-C50 circuit breaker is a series 140G, 3-pole molded case circuit breaker manufactured by Allen-Bradley. Its ratings are 690 Volts AC nominal operational voltage, 50 Amps of current at 40 degrees Celsius, 25 kA of interrupting/breaking capacity, 800 Volts (rms) insulation voltage, 8000 cycles electrical service life, and 25,000 cycles of mechanical service life. It has an H size frame, and its width, height, and depth measure 90 millimeters, 130 millimeters, and 82.5 millimeters, respectively. Arc-extinguishing technology is built into the 140G-H2C3-C50 molded case circuit breaker to reduce the effect of arcing when its contacts are opened. Its electronic circuits are protected from condensation and its metal components such as the terminals are treated for anti-corrosion protection. This circuit breaker can be mounted horizontally or vertically without reducing its performance.



The trip unit of the Allen-Bradley 140G-H2C3-C50 molded case circuit breaker is a fixed thermal and fixed magnetic trip unit. The thermal trip is rated at 50 Amps and the magnetic trip is rated at 500 Amps. This unit offers short circuit, overcurrent, and conductor protection. It is suitable for reverse feed use and it has electromagnetic compatibility for global standards. A wide array of operating mechanisms are compatible with the 140G-H2C3-C50 molded case circuit breaker to match different panel configurations. Its built-in operating device is a toggle type switch that also indicates whether it is ON, OFF, or TRIPPED. This unit supports remote operation via an Allen-Bradley motor operator device and it can also be used in combination with contactors, motor starters, and overload relays.



Technical Description of 140G-H2C3-C50

The Allen-Bradley 140G-H2C3-C50 Molded Case Circuit Breaker has a H Frame and 125 Amps. It also has a 25 kA Interrupting Rating and 3 Poles.

Repair Services for 140G-H2C3-C50

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 140G-H2C3-C50. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions for 140G-H2C3-C50

Please refer to the manual for more information about the 140G-H2C3-C50 such as the wiring diagrams, data sheets and migration or obsolescence details.

Revision Part # Also Known as Availability
140G-H2C3-C50 Ser A
140G-H2C3-C50/A, Series A, Rev A Request Quote
Common misspellings:
  • l40G-H2C3-C50
  • 1A0G-H2C3-C50
  • 14oG-H2C3-C50
  • 140G-H2C3-C5o
  • 140GH2C3C50

Dimensions For 140G-H2C3-C50

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For 140G-H2C3-C50

Resolutions For 140G-H2C3-C50

About

Technical Specifications for 140G-H2C3-C50

ManufacturerEaton Cutler-Hammer
BrandEaton Cutler-Hammer
Part Number/Catalog No.140G-H2C3-C50
Product TypeMolded Case Circuit Breaker
FrameH
Amps125
Interrupting Rating25 kA
Protection TypeFixed Thermal/ Fixed Magnetic
Current Range50 A
Rated Insulation Voltage1000 V
Rated Impulse Withstand Voltage8 kV
Weight2.65 lb
Mechanical Life240 Operations/hr.
Electrical Life120 Operations/ hr.
ManufacturerEaton Cutler-Hammer
BrandEaton Cutler-Hammer
Part Number/Catalog No.140G-H2C3-C50
Product TypeMolded Case Circuit Breaker
FrameH
Amps125
Interrupting Rating25 kA
Protection TypeFixed Thermal/ Fixed Magnetic
Current Range50 A
Rated Insulation Voltage1000 V
Rated Impulse Withstand Voltage8 kV
Weight2.65 lb
Mechanical Life240 Operations/hr.
Electrical Life120 Operations/ hr.

About 140G-H2C3-C50

The 140G-H2C3-C50 circuit breaker is a series 140G, 3-pole molded case circuit breaker manufactured by Allen-Bradley. Its ratings are 690 Volts AC nominal operational voltage, 50 Amps of current at 40 degrees Celsius, 25 kA of interrupting/breaking capacity, 800 Volts (rms) insulation voltage, 8000 cycles electrical service life, and 25,000 cycles of mechanical service life. It has an H size frame, and its width, height, and depth measure 90 millimeters, 130 millimeters, and 82.5 millimeters, respectively. Arc-extinguishing technology is built into the 140G-H2C3-C50 molded case circuit breaker to reduce the effect of arcing when its contacts are opened. Its electronic circuits are protected from condensation and its metal components such as the terminals are treated for anti-corrosion protection. This circuit breaker can be mounted horizontally or vertically without reducing its performance.



The trip unit of the Allen-Bradley 140G-H2C3-C50 molded case circuit breaker is a fixed thermal and fixed magnetic trip unit. The thermal trip is rated at 50 Amps and the magnetic trip is rated at 500 Amps. This unit offers short circuit, overcurrent, and conductor protection. It is suitable for reverse feed use and it has electromagnetic compatibility for global standards. A wide array of operating mechanisms are compatible with the 140G-H2C3-C50 molded case circuit breaker to match different panel configurations. Its built-in operating device is a toggle type switch that also indicates whether it is ON, OFF, or TRIPPED. This unit supports remote operation via an Allen-Bradley motor operator device and it can also be used in combination with contactors, motor starters, and overload relays.



Technical Description of 140G-H2C3-C50

The Allen-Bradley 140G-H2C3-C50 Molded Case Circuit Breaker has a H Frame and 125 Amps. It also has a 25 kA Interrupting Rating and 3 Poles.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 140G-H2C3-C50. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 140G-H2C3-C50. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions

Please refer to the manual for more information about the 140G-H2C3-C50 such as the wiring diagrams, data sheets and migration or obsolescence details.

Revision Part # Also Known as Availability
140G-H2C3-C50 Ser A
140G-H2C3-C50/A, Series A, Rev A Request Quote

Common misspellings:
  • l40G-H2C3-C50
  • 1A0G-H2C3-C50
  • 14oG-H2C3-C50
  • 140G-H2C3-C5o
  • 140GH2C3C50
PDF