Product image is representative; revision or series may vary. Contact us to request a specific version.
The Allen-Bradley/Rockwell Automation 140G-H2F3-C80 circuit breaker is a Bulletin 140G series molded case circuit breaker that supports adjustable thermal and adjustable magnetic trip ratings. The users can adjust the trip ratings of this circuit breaker according to the specific needs of their systems. The 140G-H2F3-C80 molded case circuit breaker’s thermal trip ratings can be adjusted between 56 and 80 Amps and its magnetic trip ratings can be adjusted between 400 and 800 Amps. It can be used for short-circuit, disconnecting, or thermal protection functions in a control panel. The 140G-H2F3-C80 molded case circuit breaker comes with 3 built-in poles.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Molded Case Circuit Breaker |
| Product Line | 140G MCB |
| Part Number | 140G-H2F3-C80 |
| Weight | 3.00 lbs (1.36 kg) |
| Frame | H |
| Amps | 125 |
| Interrupting Rating | 25 kA |
| Protection Type | Adjust Thermal/ Adjust Magnetic |
| Current Range | 80 A |
| Rated Insulation Voltage | 1000 V |
| Rated Impulse Withstand Voltage | 8 kV |
| Mechanical Life | 240 Operations/hr. |
| Electrical Life | 120 Operations/ hr. |
The Allen-Bradley 140G-H2F3-C80 circuit breaker is an 80 Amps rated circuit breaker. It is part of the 140G molded case circuit breaker series which is available in 3 and 4-pole versions, it offers high interrupt ratings from 18 to 100 kiloamps of interrupt capacity, and it offers customization and a wide range of accessories. The 140G-H2F3-C80 circuit breaker is an H Frame breaker with 25 kiloamps of interrupt capacity. The number of poles on the 140G-H2F3-C80 circuit breaker is 3 and the rated current is 80 Amps at 40 degrees Celsius. The breaker is rated at 50 to 60 Hertz line frequency. The rating for short-circuit breaker capacity is 36 kiloamps at both 250 Volts DC and 500 Volts DC. The ratings for short-circuit breaking capacity at 220 to 240 Volts AC, 400 to 415 Volts AC, 500 Volts AC, and 690 Volts AC are 65 kiloamps, 36 kiloamps, 30 kiloamps, and 10 kiloamps, respectively.
The 140G-H2F3-C80 circuit breaker can withstand an impulse voltage of 8 kilovolts. The rated insulation voltage for the breaker is 800 Volts RMS. The breaker supports a  reverse connected supply. The trip unit on the breaker is the adjustable thermal and adjustable magnetic type. The weight of the 140G-H2F3-C80 circuit breaker is approximately 1.2 kilograms. The dimensions of the breaker are 130 x 90 x 82.5 millimeters. The electrical service life of the device is 8000 cycles and the mechanical service life is 25,000 cycles. The maximum altitude at which the breaker does not derate is 2000 meters. The operating temperature range is from -25 to 70 degrees Celsius. The 140G-H2F3-C80 circuit breaker complies with the AS 60947-2 and IEC 60947-2 standards.
| Revision Part # | Also known as | |
|---|---|---|
| 140G-H2F3-C80 Ser A | 140G-H2F3-C80/A, Series A, Rev A | |
| Don't see your particular revision? Contact us now. | ||
The Allen-Bradley 140G-H2F3-C80 Molded Case Circuit Breaker has a H Frame and 125 Amps. It also has a 25 kA Interrupting Rating and 3 Poles.