The 140G-I2C3-C63, a molded case circuit breaker by Allen-Bradley, is engineered for robust performance. This model operates at 225 amperes and features a 25 kA interrupting capacity, making it suitable for high-demand applications.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Molded Case Circuit Breaker |
| Product Line | 140G MCB |
| Part Number | 140G-I2C3-C63 |
| Weight | 3.00 lbs (1.36 kg) |
| Frame | I |
| Amps | 225 |
| Interrupting Rating | 25 kA |
| Protection Type | Fixed Thermal/ Fixed Magnetic |
| Current Range | 63 A |
| Rated Insulation Voltage | 800V |
| Rated Impulse Withstand Voltage | 8 kV |
| Thermal Trip | 63 A |
| Magnetic Trip | 630 A |
The 140G-I2C3-C63 from Allen-Bradley is a molded case circuit breaker crafted for dependable circuit protection. Within this device's architecture, it utilizes a frame type classified as I. It is rated at a maximum of 225 Amps, allowing for significant current management. This circuit breaker presents an interrupting capability of 25 kA, ensuring it can mitigate fault conditions effectively.
Fixed thermal and fixed magnetic protection types are incorporated, which provide necessary safeguards against overloads and short circuits. The current range is accommodated at 63 A, enabling applicability for various electrical setups.
Operational safety is enhanced with a rated insulation voltage of 800V, while the unit stands resilient against voltage spikes, thanks to its rated impulse withstand voltage of 8 kV. At a weight of 3.75 lb, this circuit breaker combines robustness with manageable handling.
Thermal trip settings are established at 63 A, further complemented by a magnetic trip rating of 630 A, illustrating its extensive protective capabilities for diverse applications. Overall, the 140G-I2C3-C63 serves as an essential component for maintaining circuit integrity in a wide range of industrial environments.