140G-I3C4-D20
Preowned
Includes a 1-Year DO Supply warranty.
DO Supply is not an authorized distributor for Allen Bradley.
Preowned
Includes a 1-Year DO Supply warranty.
DO Supply is not an authorized distributor for Allen Bradley.
Warranty: | 1 year DO Supply Warranty Included |
Shipping: | Worldwide shipping via UPS, DHL, and TNT |
Repairs: | We offer repair service for the 140G-I3C4-D20. |
Exchange: | Exchange credit for your defective unit available. |
Conditions: | We sell preowned surplus and refurbished parts. |
Manufacturer | Eaton Cutler-Hammer |
Brand | Eaton Cutler-Hammer |
Part Number/Catalog No. | 140G-I3C4-D20 |
Product Type | Molded Case Circuit Breaker |
Frame | I |
Amps | 225 |
Interrupting Rating | 35 kA |
Protection Type | Fixed Thermal/ Fixed Magnetic |
Poles | 4 |
Current Range | 200 A |
Rated Insulation Voltage | 800V |
Rated Impulse Withstand Voltage | 8 kV |
Weight | 5.73 lb |
Thermal Trip | 200 A |
Magnetic Trip | 2000 A |
Manufacturer | Eaton Cutler-Hammer |
Brand | Eaton Cutler-Hammer |
Part Number/Catalog No. | 140G-I3C4-D20 |
Product Type | Molded Case Circuit Breaker |
Frame | I |
Amps | 225 |
Interrupting Rating | 35 kA |
Protection Type | Fixed Thermal/ Fixed Magnetic |
Poles | 4 |
Current Range | 200 A |
Rated Insulation Voltage | 800V |
Rated Impulse Withstand Voltage | 8 kV |
Weight | 5.73 lb |
Thermal Trip | 200 A |
Magnetic Trip | 2000 A |
The 140G-I3C4-D20 circuit breaker is an Allen-Bradley 140G circuit breaker with an I Frame enclosure and a 200 Amps current rating. Because the 140G-I3C4-D20 circuit breaker is a high current/high voltage device, therefore extreme care should be taken while installing and servicing this breaker to prevent electric shock. This breaker should be installed inside an appropriate enclosure where it is protected from dangerous contaminants. The 140G-I3C4-D20 circuit breaker features a fixed thermal/magnetic trip unit. The 140G molded case circuit breakers are designed for industrial panel protection. A compact size, 10 to 3000 Amp current ratings, availability in 3-pole and 4-pole options, and certification by the UL, IEC, and CSA standards are some of the salient features of this circuit breaker.
The 140G-I3C4-D20 circuit breaker is an I Frame breaker with 2.1 kilograms of weight and which measures 150 x 140 x 70 millimeters (height x width x depth). Either aluminum or copper wire with a 75 degrees Celsius temperature rating can be used for the breaker terminations. The current rating, thermal trip threshold, and magnetic trip threshold for the 140G-I3C4-D20 circuit breaker are 200 Amps, 200 Amps, and 2000 Amps, respectively. The 140G-I3C4-D20 circuit breaker is rated for 35 kiloamps interrupting capacity at 480 Volts AC. The rated insulation voltage for the 140G-I3C4-D20 circuit breaker is 800 Volts and the impulse withstand voltage rating is 8 kilovolts. The maximum recommended operating temperature is 40 degrees Celsius. The recommended temperature range for breaker storage is from -40 to 80 degrees Celsius. The 140G-I3C4-D20 circuit breaker comes with a rated mechanical life of 25,000 operations at 240 operations per hour.
The Allen-Bradley 140G-I3C4-D20 Molded Case Circuit Breaker has a I Frame and 225 Amps. It also has a 35 kA Interrupting Rating and 4 Poles.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 140G-I3C4-D20. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Please refer to the manual for more information about the 140G-I3C4-D20 such as the wiring diagrams, data sheets and migration or obsolescence details.
Revision Part # | Also Known as | Availability |
140G-I3C4-D20 Ser A
|
140G-I3C4-D20/A, Series A, Rev A | Request Quote |
Size | |
Input Type | |
Panel Cutout Height | in mm |
Panel Cutout Width | in mm |
Terminal Height | in mm |
Terminal Width | in mm |
Terminal Overall Depth | in mm |
Terminal Mounted Depth | in mm |
Manufacturer | Eaton Cutler-Hammer |
Brand | Eaton Cutler-Hammer |
Part Number/Catalog No. | 140G-I3C4-D20 |
Product Type | Molded Case Circuit Breaker |
Frame | I |
Amps | 225 |
Interrupting Rating | 35 kA |
Protection Type | Fixed Thermal/ Fixed Magnetic |
Poles | 4 |
Current Range | 200 A |
Rated Insulation Voltage | 800V |
Rated Impulse Withstand Voltage | 8 kV |
Weight | 5.73 lb |
Thermal Trip | 200 A |
Magnetic Trip | 2000 A |
Manufacturer | Eaton Cutler-Hammer |
Brand | Eaton Cutler-Hammer |
Part Number/Catalog No. | 140G-I3C4-D20 |
Product Type | Molded Case Circuit Breaker |
Frame | I |
Amps | 225 |
Interrupting Rating | 35 kA |
Protection Type | Fixed Thermal/ Fixed Magnetic |
Poles | 4 |
Current Range | 200 A |
Rated Insulation Voltage | 800V |
Rated Impulse Withstand Voltage | 8 kV |
Weight | 5.73 lb |
Thermal Trip | 200 A |
Magnetic Trip | 2000 A |
The 140G-I3C4-D20 circuit breaker is an Allen-Bradley 140G circuit breaker with an I Frame enclosure and a 200 Amps current rating. Because the 140G-I3C4-D20 circuit breaker is a high current/high voltage device, therefore extreme care should be taken while installing and servicing this breaker to prevent electric shock. This breaker should be installed inside an appropriate enclosure where it is protected from dangerous contaminants. The 140G-I3C4-D20 circuit breaker features a fixed thermal/magnetic trip unit. The 140G molded case circuit breakers are designed for industrial panel protection. A compact size, 10 to 3000 Amp current ratings, availability in 3-pole and 4-pole options, and certification by the UL, IEC, and CSA standards are some of the salient features of this circuit breaker.
The 140G-I3C4-D20 circuit breaker is an I Frame breaker with 2.1 kilograms of weight and which measures 150 x 140 x 70 millimeters (height x width x depth). Either aluminum or copper wire with a 75 degrees Celsius temperature rating can be used for the breaker terminations. The current rating, thermal trip threshold, and magnetic trip threshold for the 140G-I3C4-D20 circuit breaker are 200 Amps, 200 Amps, and 2000 Amps, respectively. The 140G-I3C4-D20 circuit breaker is rated for 35 kiloamps interrupting capacity at 480 Volts AC. The rated insulation voltage for the 140G-I3C4-D20 circuit breaker is 800 Volts and the impulse withstand voltage rating is 8 kilovolts. The maximum recommended operating temperature is 40 degrees Celsius. The recommended temperature range for breaker storage is from -40 to 80 degrees Celsius. The 140G-I3C4-D20 circuit breaker comes with a rated mechanical life of 25,000 operations at 240 operations per hour.
The Allen-Bradley 140G-I3C4-D20 Molded Case Circuit Breaker has a I Frame and 225 Amps. It also has a 35 kA Interrupting Rating and 4 Poles.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 140G-I3C4-D20. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 140G-I3C4-D20. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Please refer to the manual for more information about the 140G-I3C4-D20 such as the wiring diagrams, data sheets and migration or obsolescence details.
Revision Part # | Also Known as | Availability |
140G-I3C4-D20 Ser A
|
140G-I3C4-D20/A, Series A, Rev A | Request Quote |