Manufacturer | Eaton Cutler-Hammer |
Brand | Eaton Cutler-Hammer |
Part Number/Catalog No. | 140G-J2F3-D15 |
Product Type | Molded Case Circuit Breaker |
Frame | J |
Amps | 250 |
Interrupting Rating | 25 kA |
Protection Type | Adjust Thermal/ Adjust Magnetic |
Current Range | 150 A |
Rated Insulation Voltage | 1000V |
Rated Impulse Withstand Voltage | 8 kV |
Weight | 5.51 lb |
Mechanical Life | 240 Operations/hr. |
Electrical Life | 120 Operations/ hr. |
Manufacturer | Eaton Cutler-Hammer |
Brand | Eaton Cutler-Hammer |
Part Number/Catalog No. | 140G-J2F3-D15 |
Product Type | Molded Case Circuit Breaker |
Frame | J |
Amps | 250 |
Interrupting Rating | 25 kA |
Protection Type | Adjust Thermal/ Adjust Magnetic |
Current Range | 150 A |
Rated Insulation Voltage | 1000V |
Rated Impulse Withstand Voltage | 8 kV |
Weight | 5.51 lb |
Mechanical Life | 240 Operations/hr. |
Electrical Life | 120 Operations/ hr. |
The Allen-Bradley 140G-J2F3-D15 circuit breaker is an adjustable thermal adjustable magnetic molded case circuit breaker. Its operating voltage is rated at 600 Volts AC and it has 3 poles. The 140G-J2F3-D15 circuit breaker contains a non-interchangeable trip unit that supports long-time and instantaneous trip functions. This circuit breaker uses a molded case for protection. A molded case is advantageous since it provides insulation to the internal components of the circuit breaker. Additionally, a molded case circuit breaker like the 140G-J2F3-D15 circuit breaker requires minimal maintenance. The 140G-J2F3-D15 circuit breaker, like other J Frame thermal-magnetic circuit breakers in the 140G family, is calibrated with a maximum temperature of 40 degrees Celsius. At 40 degrees Celsius, the circuit breaker has a current range rating of 150 Amps. The 140G-J2F3-D15 circuit breaker has a watt loss rating of 23.5 Watts.
The 140G-J2F3-D15 circuit breaker, like other J Frame circuit breakers, supports a bus bar with a minimum width of 0.669 inches, a maximum width of 0.984 inches, a minimum thickness of 0.197 inches, a maximum thickness of 0.315 inches, and a terminal hole with a diameter of 0.335 inches and a hole center of 0.37 inches. Note that the bus bar accommodates a terminal torque of 8 N-m. The Allen-Bradley 140G-J2F3-D15 circuit breaker has an interrupting capacity of 25 kiloAmps at 480 Volts AC and it supports bolt-on connections. Even though this breaker uses a molded case, regular supervision should be carried out to prevent dangerous conditions such as loose terminals. Since the 140G-J2F3-D15 circuit breaker has a non-interchangeable trip unit, damaged connections require the replacement of the circuit breaker.
The Allen-Bradley 140G-J2F3-D15 Molded Case Circuit Breaker has a J Frame and 250 Amps. It also has a 25 kA Interrupting Rating and 3 Poles.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 140G-J2F3-D15. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Please refer to the manual for more information about the 140G-J2F3-D15 such as the wiring diagrams, data sheets and migration or obsolescence details.
Revision Part # | Also Known as | Availability |
140G-J2F3-D15 Ser A
|
140G-J2F3-D15/A, Series A, Rev A | Request Quote |
Size | |
Input Type | |
Panel Cutout Height | in mm |
Panel Cutout Width | in mm |
Terminal Height | in mm |
Terminal Width | in mm |
Terminal Overall Depth | in mm |
Terminal Mounted Depth | in mm |
Manufacturer | Eaton Cutler-Hammer |
Brand | Eaton Cutler-Hammer |
Part Number/Catalog No. | 140G-J2F3-D15 |
Product Type | Molded Case Circuit Breaker |
Frame | J |
Amps | 250 |
Interrupting Rating | 25 kA |
Protection Type | Adjust Thermal/ Adjust Magnetic |
Current Range | 150 A |
Rated Insulation Voltage | 1000V |
Rated Impulse Withstand Voltage | 8 kV |
Weight | 5.51 lb |
Mechanical Life | 240 Operations/hr. |
Electrical Life | 120 Operations/ hr. |
Manufacturer | Eaton Cutler-Hammer |
Brand | Eaton Cutler-Hammer |
Part Number/Catalog No. | 140G-J2F3-D15 |
Product Type | Molded Case Circuit Breaker |
Frame | J |
Amps | 250 |
Interrupting Rating | 25 kA |
Protection Type | Adjust Thermal/ Adjust Magnetic |
Current Range | 150 A |
Rated Insulation Voltage | 1000V |
Rated Impulse Withstand Voltage | 8 kV |
Weight | 5.51 lb |
Mechanical Life | 240 Operations/hr. |
Electrical Life | 120 Operations/ hr. |
The Allen-Bradley 140G-J2F3-D15 circuit breaker is an adjustable thermal adjustable magnetic molded case circuit breaker. Its operating voltage is rated at 600 Volts AC and it has 3 poles. The 140G-J2F3-D15 circuit breaker contains a non-interchangeable trip unit that supports long-time and instantaneous trip functions. This circuit breaker uses a molded case for protection. A molded case is advantageous since it provides insulation to the internal components of the circuit breaker. Additionally, a molded case circuit breaker like the 140G-J2F3-D15 circuit breaker requires minimal maintenance. The 140G-J2F3-D15 circuit breaker, like other J Frame thermal-magnetic circuit breakers in the 140G family, is calibrated with a maximum temperature of 40 degrees Celsius. At 40 degrees Celsius, the circuit breaker has a current range rating of 150 Amps. The 140G-J2F3-D15 circuit breaker has a watt loss rating of 23.5 Watts.
The 140G-J2F3-D15 circuit breaker, like other J Frame circuit breakers, supports a bus bar with a minimum width of 0.669 inches, a maximum width of 0.984 inches, a minimum thickness of 0.197 inches, a maximum thickness of 0.315 inches, and a terminal hole with a diameter of 0.335 inches and a hole center of 0.37 inches. Note that the bus bar accommodates a terminal torque of 8 N-m. The Allen-Bradley 140G-J2F3-D15 circuit breaker has an interrupting capacity of 25 kiloAmps at 480 Volts AC and it supports bolt-on connections. Even though this breaker uses a molded case, regular supervision should be carried out to prevent dangerous conditions such as loose terminals. Since the 140G-J2F3-D15 circuit breaker has a non-interchangeable trip unit, damaged connections require the replacement of the circuit breaker.
The Allen-Bradley 140G-J2F3-D15 Molded Case Circuit Breaker has a J Frame and 250 Amps. It also has a 25 kA Interrupting Rating and 3 Poles.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 140G-J2F3-D15. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 140G-J2F3-D15. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Please refer to the manual for more information about the 140G-J2F3-D15 such as the wiring diagrams, data sheets and migration or obsolescence details.
Revision Part # | Also Known as | Availability |
140G-J2F3-D15 Ser A
|
140G-J2F3-D15/A, Series A, Rev A | Request Quote |