The 140G-J6F3-D10 molded case circuit breaker is an Allen-Bradley/Rockwell Automation Bulletin 140G molded case circuit breaker. It operates as both a thermal and a magnetic circuit breaker with adjustable trip ratings. This means that the users of the 140G-J6F3-D10 molded case circuit breaker can select the exact thermal and magnetic trip ratings that they need for their specific application. The circuit breaker’s thermal trip range is between 70 and 100 Amps while its magnetic trip range is between 500 and 1000 Amps. The 140G-J6F3-D10 molded case circuit breaker features 3 poles and a Size J frame.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Molded Case Circuit Breaker |
| Product Line | 140G MCB |
| Part Number | 140G-J6F3-D10 |
| Weight | 32.00 lbs (14.51 kg) |
| Frame | J |
| Amps | 250 |
| Interrupting Rating | 65 kA |
| Protection Type | Adjust Thermal/ Adjust Magnetic |
| Current Range | 100 A |
| Rated Insulation Voltage | 1000V |
| Rated Impulse Withstand Voltage | 8 kV |
| Mechanical Life | 240 Operations/hr. |
| Electrical Life | 120 Operations/ hr. |
The 140G-J6F3-D10 circuit breaker is a J Frame circuit breaker from Allen-Bradley/Rockwell Automation. Its frame has a current rating of 250 Amps while the breakers current range stands at 100 Amps. The 140G-J6F3-D10 circuit breaker belongs to the 140G family of circuit breakers with a molded case. Breakers in this family have high breaking capacities and a high interrupt rating. For example, the 140G-J6F3-D10 circuit breaker has its interrupting capacity rated at 65 kiloAmps at 480 Volts AC. The maximum amount of fault current supplied by a system can be calculated at any point in that system. However, the interrupting rating of the breaker must be equal to or greater than the amount of fault current that can be delivered at that point in the system where the breaker is used.
The Allen-Bradley 140G-J6F3-D10 circuit breaker, like other breakers in the same family, supports both factory and field-installed accessories. The 140G-J6F3-D10 circuit breaker features an adjustable thermal and adjustable magnetic protection type. Note that 140G circuit breakers can be reverse fed. However, when reverse feeding these devices, the line and load side terminals need to be identified properly. Notably, the interrupting capacity of the 140G-J6F3-D10 circuit breaker, like other breakers in the same family, decreases as the voltage increases. The 140G-J6F3-D10 circuit breaker has its operating voltage rated at 600 Volts AC. The circuit breaker meets global industry standards such as those from IEC, UL, and CSA. Allen-Bradley notes that further certification of the 140G-J6F3-D10 circuit breaker and other circuit breakers in the 140G series is an ongoing process.
| Revision Part # | Also known as | |
|---|---|---|
| 140G-J6F3-D10 Ser A | 140G-J6F3-D10/A, Series A, Rev A | |
| Don't see your particular revision? Contact us now. | ||
The Allen-Bradley 140G-J6F3-D10 Molded Case Circuit Breaker has a J Frame and 250 Amps. It also has a 65 kA Interrupting Rating and 3 Poles.