140U-D6D2-C12

140U-D6D2-C12

Revisions: Ser A 
Description: The 140U-D6D2-C12 circuit breaker has been manufactured by Allen-Bradley/Rockwell Automation as a molded case circuit breaker. It is available through the Allen-Bradley Bulletin 140U series of compact molded case circuit breakers. The 140U-D6D2-C12 molded case circuit breaker operates with a voltage rating of 600 Volts AC and a current rating of 12 Amps. It is also equipped with 2 poles. The 140U-D6D2-C12 molded case circuit breaker fits into a Size D frame and it can protect feeder circuits, branch circuits, or control circuits.
Rated 4.5 with 20 reviews

Preowned

Includes a 1-Year DO Supply warranty.

DO Supply is not an authorized distributor for Allen Bradley.

top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Available Now

Submit RFQ for 140U-D6D2-C12

Add more parts to quote

Description: The 140U-D6D2-C12 circuit breaker has been manufactured by Allen-Bradley/Rockwell Automation as a molded case circuit breaker. It is available through the Allen-Bradley Bulletin 140U series of compact molded case circuit breakers. The 140U-D6D2-C12 molded case circuit breaker operates with a voltage rating of 600 Volts AC and a current rating of 12 Amps. It is also equipped with 2 poles. The 140U-D6D2-C12 molded case circuit breaker fits into a Size D frame and it can protect feeder circuits, branch circuits, or control circuits.

Preowned

Includes a 1-Year DO Supply warranty.

DO Supply is not an authorized distributor for Allen Bradley.

top legal disclaimer
disclaimer
credit cards
better business bureau
Revisions: Ser A 

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via UPS, DHL, and TNT
Repairs: We offer repair service for the 140U-D6D2-C12.
Exchange: Exchange credit for your defective unit available.
Conditions: We sell preowned surplus and refurbished parts.

To speak to a sales representative for pricing & lead time:


Rated 4.5 with 20 reviews

    Technical Specifications for 140U-D6D2-C12

Part Number140U-D6D2-C12
Product TypeMolded Case Circuit Breaker
FrameD
Rated Current 12 A
Magnetic Trip15-20 A
Breaking Capacity65 kA
Interrupting Rating65 kA
Poles2 and 3
Rated Insulation Voltage690V IEC
Rated Frequency50/60 Hz
Part Number140U-D6D2-C12
Product TypeMolded Case Circuit Breaker
FrameD
Rated Current 12 A
Magnetic Trip15-20 A
Breaking Capacity65 kA
Interrupting Rating65 kA
Poles2 and 3
Rated Insulation Voltage690V IEC
Rated Frequency50/60 Hz
s

About 140U-D6D2-C12

A product of Allen-Bradley, the 140U-D6D2-C12 circuit breaker is a 140U MCB series circuit breaker designed and built to provide space-saving benefits. The 140U-D6D2-C12 circuit breaker and the other Allen-Bradley circuit breakers under the same series provide the users with up to 50% size reduction compared to the traditional molded case circuit breakers. The 140U-D6D2-C12 circuit breaker comes with dimensions of 45 x 102 x 85 millimeters. The 140U MCB series circuit breakers by Allen-Bradley feature a high interrupting rating of 65 kA, allowing for a higher overall panel short circuit rating. The Allen-Bradley molded case circuit breaker provides the users with up to 6 times the high interrupting rating in comparison to the conventional molded case circuit breakers.





The 140U-D6D2-C12 circuit breaker is a UL 489 compliant circuit breaker. This means that it is suitable for global applications. The Allen-Bradley circuit breakers are suitable for use in feeder and control circuits. For the feeder circuits, the 140U-D6D2-C12 circuit breaker works in small cabinets, distribution panels, branch circuits, transformers, and heaters. For the control circuits, the unit works with control transformers and power supplies. The 140U-D6D2-C12 circuit breaker comes with the Auxiliary Contact (AX) that indicates the electrical ON and OFF statuses of the breaker. This ensures easy monitoring of the circuit breaker. When the 140U-D6D2-C12 circuit breaker is tripped, the built-in alarm contact (AL) will show the status of the unit. This molded case circuit breaker features an ambient operating temperature range of -25 to 60 degrees Celsius. The ambient storage temperature range is -40 to 80 degrees Celsius, while the unit features resistance to shock and resistance to vibration.



Technical Description of 140U-D6D2-C12

The 140U-D6D2-C12 Molded Case Circuit Breaker by Allen-Bradley has a D Frame and a 12 A Rated Current. It operates with a 65 kA Breaking Capacity and a 65 kA Interrupting Rating.

Repair Services for 140U-D6D2-C12

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 140U-D6D2-C12. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions for 140U-D6D2-C12

Please refer to the manual for more information about the 140U-D6D2-C12 such as the wiring diagrams, data sheets and migration or obsolescence details.

Revision Part # Also Known as Availability
140U-D6D2-C12 Ser A
140U-D6D2-C12/A, Series A, Rev A Request Quote
Common misspellings:
  • l40U-D6D2-C12
  • 1A0U-D6D2-C12
  • 14oU-D6D2-C12
  • 140U-D6D2-Cl2
  • 140UD6D2C12

Dimensions For 140U-D6D2-C12

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For 140U-D6D2-C12

Resolutions For 140U-D6D2-C12

About

Technical Specifications for 140U-D6D2-C12

Part Number140U-D6D2-C12
Product TypeMolded Case Circuit Breaker
FrameD
Rated Current 12 A
Magnetic Trip15-20 A
Breaking Capacity65 kA
Interrupting Rating65 kA
Poles2 and 3
Rated Insulation Voltage690V IEC
Rated Frequency50/60 Hz
Part Number140U-D6D2-C12
Product TypeMolded Case Circuit Breaker
FrameD
Rated Current 12 A
Magnetic Trip15-20 A
Breaking Capacity65 kA
Interrupting Rating65 kA
Poles2 and 3
Rated Insulation Voltage690V IEC
Rated Frequency50/60 Hz

About 140U-D6D2-C12

A product of Allen-Bradley, the 140U-D6D2-C12 circuit breaker is a 140U MCB series circuit breaker designed and built to provide space-saving benefits. The 140U-D6D2-C12 circuit breaker and the other Allen-Bradley circuit breakers under the same series provide the users with up to 50% size reduction compared to the traditional molded case circuit breakers. The 140U-D6D2-C12 circuit breaker comes with dimensions of 45 x 102 x 85 millimeters. The 140U MCB series circuit breakers by Allen-Bradley feature a high interrupting rating of 65 kA, allowing for a higher overall panel short circuit rating. The Allen-Bradley molded case circuit breaker provides the users with up to 6 times the high interrupting rating in comparison to the conventional molded case circuit breakers.





The 140U-D6D2-C12 circuit breaker is a UL 489 compliant circuit breaker. This means that it is suitable for global applications. The Allen-Bradley circuit breakers are suitable for use in feeder and control circuits. For the feeder circuits, the 140U-D6D2-C12 circuit breaker works in small cabinets, distribution panels, branch circuits, transformers, and heaters. For the control circuits, the unit works with control transformers and power supplies. The 140U-D6D2-C12 circuit breaker comes with the Auxiliary Contact (AX) that indicates the electrical ON and OFF statuses of the breaker. This ensures easy monitoring of the circuit breaker. When the 140U-D6D2-C12 circuit breaker is tripped, the built-in alarm contact (AL) will show the status of the unit. This molded case circuit breaker features an ambient operating temperature range of -25 to 60 degrees Celsius. The ambient storage temperature range is -40 to 80 degrees Celsius, while the unit features resistance to shock and resistance to vibration.



Technical Description of 140U-D6D2-C12

The 140U-D6D2-C12 Molded Case Circuit Breaker by Allen-Bradley has a D Frame and a 12 A Rated Current. It operates with a 65 kA Breaking Capacity and a 65 kA Interrupting Rating.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 140U-D6D2-C12. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 140U-D6D2-C12. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions