Free UPS Ground on All Orders!
+1 (919) 205-4392
Allen Bradley 140U MCB 140U-I6C3-C20

Product image is representative; revision or series may vary. Contact us to request a specific version.

140U-I6C3-C20

|

The 140U-I6C3-C20 is a Molded Case Circuit Breaker that is part of Allen-Bradley’s Bulletin 140U This circuit breaker is a 3-Pole breaker that features a non-adjustable trip rating of 20 Amperes. It is a NEMA Starter Size 1 and applicable for use with 2 HP at 200 VAC; 3 HP at 230 VAC; 5 HP 318-415 VAC; 5 HP at 460 VAC and 7.5 HP at 575 VAC rated motors. This circuit is a Panel mounted device.

In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Rockwell Disclaimer: The product is used surplus. DO Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because DO Supply is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. DO Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. DO Supply also makes no representations as to your right to install any such firmware on the product. DO Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Technical specifications for 140U-I6C3-C20

ManufacturerAllen Bradley
CategoryPLCs
Product Line140U MCB
Part Number140U-I6C3-C20
Weight4.31 lbs (1.96 kg)
TypeMolded-case circuit breaker
SeriesBulletin 140U
Detection mechanismThermal/Magnetic
Breaker typeThermal - Magnetic Breaker
Interrupting ratingMedium
Frame typeMolded case Circuit Breaker (MCCB)
HousingNEMA 3
Frequency60 Hertz
Voltage rating240 - 600 VAC
Magnet rating500-1000 Amps
Input Voltage Phase3-Phase
Current rating125 Amps
Single Phase OperationSupported
Voltage range200-575 Volts
Continuous Current trip20 A
Horsepower Rating2 to 7.5 HP
Adjustable Current tripNo
Non-adjustable magnetic tripYes
Magnetic trip, minimum500 A
Magnetic Trip, maximum1000 A
Horsepower ratings2 HP at 200 VAC; 3 HP at 230 VAC; 5 HP 318-415 VAC; 5 HP at 460 VAC; 7.5 HP at 575 VAC
MountingPanel Mount

The 140U-I6C3-C20 is a Thermal-Magnetic circuit breaker from Allen-Bradley. This circuit breaker is a molded case frame and non-adjustable magnetic trip with a continuous current trip rating of 20 Amperes and NEMA size 1. This circuit breaker is applicable with motors rated 2 HP at 200 VAC; 3 HP at 230 VAC; 5 HP 318-415 VAC; 5 HP at 460 VAC and 7.5 HP at 575 VAC. It has a minimum magnetic trip of 500 Amperes and a Maximum of 1000 Amperes. This circuit breaker may also be used with Single-phase AC circuits. The 140U-I6C3-C20 has to interrupt rating of 100kA at 240 VAC, 65 kA at 480 VAC, 25 kA at 600 VAC, and 22 kA at 250 VDC based on UL489, CSA 22.2 No.5; 100kA at 240 VAC, 65 kA at 415 VAC, 25 kA and 22 kA at 250 VDC based on IEC 157-1; Use Copper or Aluminum wires with the 140U-I6C3-C20. With copper wires, the insulation rating must be 60 Degree Celsius while 75 Degree Celsius for Aluminum wires. For socket head terminals, used a Hex screw with a size of 3/16 inch or 5 mm and tighten with Torque amounting to 120 lb-in or 13.6 N-m. or 5/16 inch or 8 mm and apply a torque force of 275 Lb-in o 31.1 N-m. With Slotted head terminals, use 14-10 AWG or 2.5-6 mm and tighten with Torque of 35 lb-in or 4.0 N-m; 8 AWG or (10 mm) with 40 lb-in or 4.5 N-m Torque and 6-4 AWG or 16-25 mm with Torque of 45 Lb-in and 5.1 N-m.

The 140U-I6C3-C20 circuit breaker is a thermal-magnetic circuit breaker that has been designed and distributed by Allen-Bradley. This breaker is intended to operate alongside a starter and to be attached to motors and different kinds of equipment that require current protection. This breaker comes within a NEMA Type 1 enclosure that protects it against solid particles. This enclosure does not protect the breaker against liquids. The breaker is suitable to operate in a vertical, horizontal, up, or down position. It is recommended to keep distances between the breaker and other pieces of equipment to avoid overheating. The Allen-Bradley 140U-I6C3-C20 thermal-magnetic circuit breaker can operate with different ratings at a voltage range from 200 to 575 Volts and a frequency of 60 Hertz. The breaker has a continuous current rating of 20 Amps. The Allen-Bradley 140U-I6C3-C20 thermal-magnetic circuit breaker Horsepower rating goes from 2 to 7.5 Horsepower. The magnetic trip range goes from 500 to 1000 Amps. This breaker has a moderate interrupting rating among the breakers from the series. The Allen-Bradley 140U-I6C3-C20 thermal-magnetic circuit breaker consists of a non-adjustable magnetic trip that comes with a starter and it belongs to the Frame I series. When the breaker has been properly selected and installed, the combination of it with any overload relay provides protection against short-circuit and ground fault damage that can be caused by abnormal currents. It also provides overcurrent and branch circuit protection for motors that are constantly in operations. The breaker comes with three poles that are connected together that react and perform a tripping action once detection has been performed.