140U-I6C3-C20-M
Preowned
Includes a 1-Year DO Supply warranty.
DO Supply is not an authorized distributor for Allen Bradley.
Preowned
Includes a 1-Year DO Supply warranty.
DO Supply is not an authorized distributor for Allen Bradley.
Warranty: | 1 year DO Supply Warranty Included |
Shipping: | Worldwide shipping via UPS, DHL, and TNT |
Repairs: | We offer repair service for the 140U-I6C3-C20-M. |
Exchange: | Exchange credit for your defective unit available. |
Conditions: | We sell preowned surplus and refurbished parts. |
Brand | Allen-Bradley / Rockwell Automation |
Series | 140U MCB |
Part Number | 140U-I6C3-C20-M |
Description | UL Molded Case Circuit Breaker |
Frame | I |
Current Rating | 20 |
Interrupting Rating | 65 Kilo-Amps (KA) |
Protection Type | Fixed Thermal/Magnetic Trip Unit |
Number of Poles | 3 |
Rated Operating Voltage | 480 Volts AC |
Type of Control | Toggle Lever |
Terminals | End Cap Bolt-On |
Operating Temperature | -8 to 60 Degrees Celsius |
Brand | Allen-Bradley / Rockwell Automation |
Series | 140U MCB |
Part Number | 140U-I6C3-C20-M |
Description | UL Molded Case Circuit Breaker |
Frame | I |
Current Rating | 20 |
Interrupting Rating | 65 Kilo-Amps (KA) |
Protection Type | Fixed Thermal/Magnetic Trip Unit |
Number of Poles | 3 |
Rated Operating Voltage | 480 Volts AC |
Type of Control | Toggle Lever |
Terminals | End Cap Bolt-On |
Operating Temperature | -8 to 60 Degrees Celsius |
The 140U-I6C3-C20-M Molded Case Circuit Breaker is an industrial-based circuit breaker by Allen-Bradley that is designed to provide thermal overcurrent protection and short-circuit protection to a wide variety of industrial control panel applications. The 140U-I6C3-C20-M Circuit Breaker belongs to the discontinued I-Frame circuit breaker series, it is designed with a small footprint for tight panel space applications, and it also comes with up to 6 times higher interrupting ratings than traditional breakers. The 140U-I6C3-C20-M Circuit Breaker is designed for control circuits, HACR (Heating, Air Conditioning, and Refrigeration) applications. The 140U-I6C3-C20-M Molded Case Circuit Breaker comes with non-interchangeable trip units and lugs and it can be wired for IP2X ratings.
The 140U-I6C3-C20-M Circuit Breaker has a nominal current rating of 20 Amps and a high breaking capacity of 65 kA. It has an acceptable voltage range between 230 Volts AC and 690 Volts AC (50/60 Hertz) and a rated impulse withstand of 6000 Volts. The 140U-I6C3-C20-M Circuit Breaker has a 100,000 operations mechanical life cycle, and a 10,000 operations electrical life cycle. It comes with a non-interchangeable thermal and magnetic trip unit that offers fast-acting thermal and instantaneous trip actions via a bi-metallic heat element and a reverse loop contact. It comes with the standard end cap line and load side terminals, and it is shipped with mounting hardware that allows for easy field installation. The 140U-I6C3-C20-M Circuit Breaker has an operating temperature range of -8 to 60 degrees Celsius and a maximum installation height of 200 meters without de-rating. It has an average weight of 1.36 kilograms, and approximate dimensions of 140 x 76 x 76 millimeters (height x width x depth).
The Allen-Bradley 140U-I6C3-C20-M Circuit Breaker is a UL listed circuit breaker with a fixed thermal/fixed magnetic trip unit. It has a 65 kA interrupting rating at 480 Volts AC and a continuous current rating of 20 Amps.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 140U-I6C3-C20-M. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Size | |
Input Type | |
Panel Cutout Height | in mm |
Panel Cutout Width | in mm |
Terminal Height | in mm |
Terminal Width | in mm |
Terminal Overall Depth | in mm |
Terminal Mounted Depth | in mm |
Brand | Allen-Bradley / Rockwell Automation |
Series | 140U MCB |
Part Number | 140U-I6C3-C20-M |
Description | UL Molded Case Circuit Breaker |
Frame | I |
Current Rating | 20 |
Interrupting Rating | 65 Kilo-Amps (KA) |
Protection Type | Fixed Thermal/Magnetic Trip Unit |
Number of Poles | 3 |
Rated Operating Voltage | 480 Volts AC |
Type of Control | Toggle Lever |
Terminals | End Cap Bolt-On |
Operating Temperature | -8 to 60 Degrees Celsius |
Brand | Allen-Bradley / Rockwell Automation |
Series | 140U MCB |
Part Number | 140U-I6C3-C20-M |
Description | UL Molded Case Circuit Breaker |
Frame | I |
Current Rating | 20 |
Interrupting Rating | 65 Kilo-Amps (KA) |
Protection Type | Fixed Thermal/Magnetic Trip Unit |
Number of Poles | 3 |
Rated Operating Voltage | 480 Volts AC |
Type of Control | Toggle Lever |
Terminals | End Cap Bolt-On |
Operating Temperature | -8 to 60 Degrees Celsius |
The 140U-I6C3-C20-M Molded Case Circuit Breaker is an industrial-based circuit breaker by Allen-Bradley that is designed to provide thermal overcurrent protection and short-circuit protection to a wide variety of industrial control panel applications. The 140U-I6C3-C20-M Circuit Breaker belongs to the discontinued I-Frame circuit breaker series, it is designed with a small footprint for tight panel space applications, and it also comes with up to 6 times higher interrupting ratings than traditional breakers. The 140U-I6C3-C20-M Circuit Breaker is designed for control circuits, HACR (Heating, Air Conditioning, and Refrigeration) applications. The 140U-I6C3-C20-M Molded Case Circuit Breaker comes with non-interchangeable trip units and lugs and it can be wired for IP2X ratings.
The 140U-I6C3-C20-M Circuit Breaker has a nominal current rating of 20 Amps and a high breaking capacity of 65 kA. It has an acceptable voltage range between 230 Volts AC and 690 Volts AC (50/60 Hertz) and a rated impulse withstand of 6000 Volts. The 140U-I6C3-C20-M Circuit Breaker has a 100,000 operations mechanical life cycle, and a 10,000 operations electrical life cycle. It comes with a non-interchangeable thermal and magnetic trip unit that offers fast-acting thermal and instantaneous trip actions via a bi-metallic heat element and a reverse loop contact. It comes with the standard end cap line and load side terminals, and it is shipped with mounting hardware that allows for easy field installation. The 140U-I6C3-C20-M Circuit Breaker has an operating temperature range of -8 to 60 degrees Celsius and a maximum installation height of 200 meters without de-rating. It has an average weight of 1.36 kilograms, and approximate dimensions of 140 x 76 x 76 millimeters (height x width x depth).
The Allen-Bradley 140U-I6C3-C20-M Circuit Breaker is a UL listed circuit breaker with a fixed thermal/fixed magnetic trip unit. It has a 65 kA interrupting rating at 480 Volts AC and a continuous current rating of 20 Amps.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 140U-I6C3-C20-M. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 140U-I6C3-C20-M. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.