140U-K-EA2

140U-K-EA2

Description:

The 140U-K-EA2 contact is an auxiliary contact manufactured by Allen-Bradley/Rockwell Automation as part of the bulletin 140U product line. It has a K Frame size with a current rating of 400 Amps. This module comes with an auxiliary contact (AX) that electrically indicates the "on" and "off" status of the breakers.

Rated 4.6 with 12 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Available Now

Submit RFQ for 140U-K-EA2

Add more parts to quote

Description:

The 140U-K-EA2 contact is an auxiliary contact manufactured by Allen-Bradley/Rockwell Automation as part of the bulletin 140U product line. It has a K Frame size with a current rating of 400 Amps. This module comes with an auxiliary contact (AX) that electrically indicates the "on" and "off" status of the breakers.



Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 140U-K-EA2.
Exchange: Exchange credit for your defective unit available.

To speak to a sales representative for pricing & lead time:


Rated 4.6 with 12 reviews

    Technical Specifications for 140U-K-EA2

BrandAllen-Bradley / Rockwell Automation
Series140U MCB
Part Number140U-K-EA2
BrandAllen Bradley/Rockwell Automation
Series140U MCB
Part Number140U-K-EA2
Product LineMolded Case Circuit Breaker
Bulletin140U
Frame SizeK
BrandAllen-Bradley / Rockwell Automation
Series140U MCB
Part Number140U-K-EA2
BrandAllen Bradley/Rockwell Automation
Series140U MCB
Part Number140U-K-EA2
Product LineMolded Case Circuit Breaker
Bulletin140U
Frame SizeK
s

About 140U-K-EA2

The 140U-K-EA2 contact is an auxiliary contact that is manufactured by Allen-Bradley/Rockwell Automation as part of the bulletin 140U product line. It has a K Frame size with a current rating of 400 Amps. This module comes with an auxiliary contact (AX) that electrically indicates the "on" and "off" status of breakers. It also has left and right side mounting locations. The 140U-K-EA2 contact has the 2A/2B configuration type and it is suitable for use with the 140U K-frame molded case circuit breakers. The Bulletin 140U molded case circuit breakers have a thermal-magnetic current range of 15 to 800 Amps, an electronic current range of 70 to 1200 Amps, and a molded case switches current rate of 125 to 1200 Amps. Other features of these modules include field or factory-installed accessories, flex cable operating mechanisms, rotary variable-depth operating mechanisms, and high interrupting ratings in compact dimensions.



 



The Allen-Bradley 140U-K-EA2 auxiliary contact is rated and listed for the UL 489, CSA 22.2, and IEC 60947-2 standards. The product line is approved for universal applications around the world. Other specifications include interrupting ratings of 65 kiloamps at 380 to 415 Volts, 65 kiloamps at 480 Volts, 35 kiloamps at 600 Volts, and 13 kiloamps at 690 Volts. Circuit breakers with the K Frame size, including the 140U-K-EA2 contact, have field-installable internal control modules, rotary operators, flex cable operators, and molded case switches. There are different options for the electronic ratings, including a long time or short time settings, long time or short time or high instantaneous settings, long time or short time or ground fault settings, and a long time or short time or high instantaneous or ground fault setting.



Repair Services for 140U-K-EA2

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 140U-K-EA2. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For 140U-K-EA2

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For 140U-K-EA2

Resolutions For 140U-K-EA2

About

Technical Specifications for 140U-K-EA2

BrandAllen-Bradley / Rockwell Automation
Series140U MCB
Part Number140U-K-EA2
BrandAllen Bradley/Rockwell Automation
Series140U MCB
Part Number140U-K-EA2
Product LineMolded Case Circuit Breaker
Bulletin140U
Frame SizeK
BrandAllen-Bradley / Rockwell Automation
Series140U MCB
Part Number140U-K-EA2
BrandAllen Bradley/Rockwell Automation
Series140U MCB
Part Number140U-K-EA2
Product LineMolded Case Circuit Breaker
Bulletin140U
Frame SizeK

About 140U-K-EA2

The 140U-K-EA2 contact is an auxiliary contact that is manufactured by Allen-Bradley/Rockwell Automation as part of the bulletin 140U product line. It has a K Frame size with a current rating of 400 Amps. This module comes with an auxiliary contact (AX) that electrically indicates the "on" and "off" status of breakers. It also has left and right side mounting locations. The 140U-K-EA2 contact has the 2A/2B configuration type and it is suitable for use with the 140U K-frame molded case circuit breakers. The Bulletin 140U molded case circuit breakers have a thermal-magnetic current range of 15 to 800 Amps, an electronic current range of 70 to 1200 Amps, and a molded case switches current rate of 125 to 1200 Amps. Other features of these modules include field or factory-installed accessories, flex cable operating mechanisms, rotary variable-depth operating mechanisms, and high interrupting ratings in compact dimensions.



 



The Allen-Bradley 140U-K-EA2 auxiliary contact is rated and listed for the UL 489, CSA 22.2, and IEC 60947-2 standards. The product line is approved for universal applications around the world. Other specifications include interrupting ratings of 65 kiloamps at 380 to 415 Volts, 65 kiloamps at 480 Volts, 35 kiloamps at 600 Volts, and 13 kiloamps at 690 Volts. Circuit breakers with the K Frame size, including the 140U-K-EA2 contact, have field-installable internal control modules, rotary operators, flex cable operators, and molded case switches. There are different options for the electronic ratings, including a long time or short time settings, long time or short time or high instantaneous settings, long time or short time or ground fault settings, and a long time or short time or high instantaneous or ground fault setting.



Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 140U-K-EA2. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 140U-K-EA2. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

PDF