140U-K6G3-D40

140U-K6G3-D40

Description:

The Allen-Bradley 140U-K6G3-D40 Molded Case is a 140G Molded Case Circuit Breaker. It is a K-Frame circuit breaker with a rated current of 400 Amps and 3-pole configuration. It provides Electronic LSG (Long, Short, Ground Fault) protection.

Rated 4.8 with 20 reviews

Preowned

Includes a 1-Year DO Supply warranty.

DO Supply is not an authorized distributor for Allen Bradley.

top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Available Now

Submit RFQ for 140U-K6G3-D40

Add more parts to quote

Description:

The Allen-Bradley 140U-K6G3-D40 Molded Case is a 140G Molded Case Circuit Breaker. It is a K-Frame circuit breaker with a rated current of 400 Amps and 3-pole configuration. It provides Electronic LSG (Long, Short, Ground Fault) protection.


Preowned

Includes a 1-Year DO Supply warranty.

DO Supply is not an authorized distributor for Allen Bradley.

top legal disclaimer
disclaimer
credit cards
better business bureau

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via UPS, DHL, and TNT
Repairs: We offer repair service for the 140U-K6G3-D40.
Exchange: Exchange credit for your defective unit available.
Conditions: We sell preowned surplus and refurbished parts.

To speak to a sales representative for pricing & lead time:


Rated 4.8 with 20 reviews

    Technical Specifications for 140U-K6G3-D40

BrandAllen-Bradley / Rockwell Automation
Series140U MCB
Part Number140U-K6G3-D40
FamilyBulletin 140U
Type140U
Pole3-poles
Frame SizeK-Frame
Supply Voltage480V
Interrupting Rate65 kA
Rated Current400 Amps
Protection TypeElectronic LSG (Long, Short, Ground Fault)
Ambient Temperature104 degrees Fahrenheit (40 degrees Celsius)
Storage Temperature-40 to 176 degrees Fahrenheit (-40 to 80 degrees Celsius)
Dimensions140 x 108.5 x 205 mm
BrandAllen-Bradley / Rockwell Automation
Series140U MCB
Part Number140U-K6G3-D40
FamilyBulletin 140U
Type140U
Pole3-poles
Frame SizeK-Frame
Supply Voltage480V
Interrupting Rate65 kA
Rated Current400 Amps
Protection TypeElectronic LSG (Long, Short, Ground Fault)
Ambient Temperature104 degrees Fahrenheit (40 degrees Celsius)
Storage Temperature-40 to 176 degrees Fahrenheit (-40 to 80 degrees Celsius)
Dimensions140 x 108.5 x 205 mm
s

About 140U-K6G3-D40

The Allen-Bradley 140U-K6G3-D40 circuit breaker has a supply voltage of 480 Volts, an interrupting rate of 65 kA, a rated current of 400 Amps, and a 3-pole configuration. It provides Electronic LSG protection (Long, Short, Ground Fault). It has factory-assembled internal control modules which are mounted on both the left side and the right side of the circuit breakers. Modules mounted on the left side include the Undervoltage Release (UVT) and Shunt Trip (SNT) module whereas modules mounted on the right side include the Auxiliary Contact (AX) and Alarm Contact (AL) modules and a combination of Auxiliary/Alarm Contact (AX/AL) module. The main function of the Allen-Bradley 140U-K6G3-D40 circuit breaker is to protect circuits against short-circuits, ground faults, and overloads. The circuit protection devices are installed in bus-bar trunking tap-offs, switchboards, panelboards, and individual enclosures.



 



In addition, the Allen-Bradley 140U-K6G3-D40 Molded Case Circuit Breaker has external accessories including Terminal Shields, a Flex-Cable Operating Mechanism, a Rotary Variable-Depth Operating Mechanism, a Rotary Direct Couple Operating Mechanism, an End Cap Kit, Phase Barriers, and Mounting Hardware. The 140U-K6G3-D40 Circuit Breaker is accredited with certifications including the CCC, CE Mark, CSA, and UL List standards and it can work with the IE3 Motors (IEC 60034-30). It is approved for global applications by the IEC, CSA, CCC, and UL standards for its interrupting/breaking capacity. The MCCB has a storage temperature range from -40 to 176 degrees Fahrenheit (-40 to 80 degrees Celsius) and a maximum ambient temperature rating of 104 degrees Fahrenheit (40 degrees Celsius) without derating. It is a compact device with dimensions of 140 x 108.5 x 205 millimeters.



Repair Services for 140U-K6G3-D40

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 140U-K6G3-D40. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For 140U-K6G3-D40

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For 140U-K6G3-D40

Resolutions For 140U-K6G3-D40

About

Technical Specifications for 140U-K6G3-D40

BrandAllen-Bradley / Rockwell Automation
Series140U MCB
Part Number140U-K6G3-D40
FamilyBulletin 140U
Type140U
Pole3-poles
Frame SizeK-Frame
Supply Voltage480V
Interrupting Rate65 kA
Rated Current400 Amps
Protection TypeElectronic LSG (Long, Short, Ground Fault)
Ambient Temperature104 degrees Fahrenheit (40 degrees Celsius)
Storage Temperature-40 to 176 degrees Fahrenheit (-40 to 80 degrees Celsius)
Dimensions140 x 108.5 x 205 mm
BrandAllen-Bradley / Rockwell Automation
Series140U MCB
Part Number140U-K6G3-D40
FamilyBulletin 140U
Type140U
Pole3-poles
Frame SizeK-Frame
Supply Voltage480V
Interrupting Rate65 kA
Rated Current400 Amps
Protection TypeElectronic LSG (Long, Short, Ground Fault)
Ambient Temperature104 degrees Fahrenheit (40 degrees Celsius)
Storage Temperature-40 to 176 degrees Fahrenheit (-40 to 80 degrees Celsius)
Dimensions140 x 108.5 x 205 mm

About 140U-K6G3-D40

The Allen-Bradley 140U-K6G3-D40 circuit breaker has a supply voltage of 480 Volts, an interrupting rate of 65 kA, a rated current of 400 Amps, and a 3-pole configuration. It provides Electronic LSG protection (Long, Short, Ground Fault). It has factory-assembled internal control modules which are mounted on both the left side and the right side of the circuit breakers. Modules mounted on the left side include the Undervoltage Release (UVT) and Shunt Trip (SNT) module whereas modules mounted on the right side include the Auxiliary Contact (AX) and Alarm Contact (AL) modules and a combination of Auxiliary/Alarm Contact (AX/AL) module. The main function of the Allen-Bradley 140U-K6G3-D40 circuit breaker is to protect circuits against short-circuits, ground faults, and overloads. The circuit protection devices are installed in bus-bar trunking tap-offs, switchboards, panelboards, and individual enclosures.



 



In addition, the Allen-Bradley 140U-K6G3-D40 Molded Case Circuit Breaker has external accessories including Terminal Shields, a Flex-Cable Operating Mechanism, a Rotary Variable-Depth Operating Mechanism, a Rotary Direct Couple Operating Mechanism, an End Cap Kit, Phase Barriers, and Mounting Hardware. The 140U-K6G3-D40 Circuit Breaker is accredited with certifications including the CCC, CE Mark, CSA, and UL List standards and it can work with the IE3 Motors (IEC 60034-30). It is approved for global applications by the IEC, CSA, CCC, and UL standards for its interrupting/breaking capacity. The MCCB has a storage temperature range from -40 to 176 degrees Fahrenheit (-40 to 80 degrees Celsius) and a maximum ambient temperature rating of 104 degrees Fahrenheit (40 degrees Celsius) without derating. It is a compact device with dimensions of 140 x 108.5 x 205 millimeters.



Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 140U-K6G3-D40. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 140U-K6G3-D40. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

PDF