The Allen-Bradley 140U-KTD3-D40 molded case circuit breaker is part of the 140U MCB product line. The unit has a K Frame with 400 Amps of current rating and it features a trip unit with fixed thermal and adjustable magnetic protection. This three-pole circuit breaker has a current ratingĀ of 4000 Amps.
We sell industrial automation parts backed by our 2-year DO Supply Warranty.
Same-day domestic and expedited international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, and more, plus flexible payment plans.
Repair and exchange services for all existing automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
Brand | Allen Bradley/Rockwell Automation |
---|---|
Series | 140U MCB |
Part Number | 140U-KTD3-D40 |
Product Line | Molded Case Circuit Breaker |
Frame Size | K |
Current Rating | 400 Amperes |
Current Range | 4000 Amperes |
Bulletin | 140U |
The Allen-Bradley 140U-KTD3-D40 molded case circuit breaker is part of the 140U MCB product line. The unit has a K Frame with 400 Amps of current rating and it features a trip unit with fixed thermal and adjustable magnetic protection. This three-pole circuit breaker has a current range of 4000 Amps. Some of the features of the K Frame circuit breakers are field-installed internal control modules, molded case switches, rotary operators, and flex cable operators. The 140U-KTD3-D40 molded case circuit breakerĀ also comes with high interrupting ratings in compact dimensions and field-installed or factory-installed accessories. It isĀ globally approved and listed for universal applications aroundĀ the world. The 140U-KTD3-D40 circuit breaker also comes with an interrupting rating of 35 kiloamps at 600 Volts, 65 kiloamps at 380 to 415 Volts, 13 kiloamps at 690 Volts, and 65 kiloamps at 480 Volts. ThisĀ circuit breaker also hasĀ flex cable operating devices as well as rotary variable-depth operating mechanisms.
The Allen-BradleyĀ 140U-KTD3-D40 molded case circuit breaker is listed and rated for compliance with the UL 489, CE, KEMA-KEUR CSA, and IEC standards. This circuit breaker has a fixed thermal trip adjustment ratingĀ of 300 Amps and a magnetic trip adjustment range of 1500 to 3000 Amps. The 140U-KTD3-D40 circuit breaker also has a thermal-magnetic current range of 15 toĀ 800 Amps and aĀ molded case switchĀ current range of 125 toĀ 1200 Amps. It has an electric current range of 70 toĀ 1200 Amps with options including a long time or a short time setting, long time or short time or high instantaneous setting, long time or short time or ground fault setting, and a long time or short time or high instantaneous or ground fault setting.