The Allen-Bradley 140UE-M7D3-D40 circuit breaker is an IEC molded case circuit breaker. The number of poles found on the 140UE-M7D3-D40 circuit breaker is three and it is rated for 400 Amps of current. The protection type available on the breaker is FA protection. The trip unit on the 140UE-M7D3-D40 circuit breakerĀ is a fixed thermal andĀ adjustable magnetic circuit breaker. The frame of the breaker is an M frame which is rated for a maximum current of 800 Amps.
We sell industrial automation parts backed by our 2-year DO Supply Warranty.
Same-day domestic and expedited international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, and more, plus flexible payment plans.
Repair and exchange services for all existing automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
Brand | Allen-Bradley / Rockwell Automation |
---|---|
Series | 140U MCB |
Part Number | 140UE-M7D3-D40 |
Product type | IEC molded case circuit breaker |
Poles | 3 |
Current rating | 400 Amps |
Trip module | Fixed thermal - adjustable magnetic |
Dimensions | 407 x 210 x 104 millimeters |
Frame | M |
The Allen-Bradley 140UE-M7D3-D40 circuit breaker is an IEC molded case circuit breaker. The number of poles that are foundĀ on the 140UE-M7D3-D40 circuit breaker is three and this breaker isĀ rated for 400 Amps of current. The protection type that is available on the breaker is FA protection. The trip unit on the 140UE-M7D3-D40 circuit breaker is a fixed thermal andĀ adjustable magnetic circuit breaker. The frame of the circuit breaker is an M frame which is rated for a maximum current rating of 800 Amps. The 140UE-M7D3-D40 circuit breaker complies with multiple industrial standards including the CE, KEMA-KEUR, and the IEC 60947-2 standards. The terminal box lugs and mounting hardware for the circuit breaker must be ordered separately. The rated service breaking capacity ratings at 50 Hertz line frequency for the 140UE-M7D3-D40 circuit breaker areĀ 100 kiloamps at 220 to 240 Volts AC, 50 kiloamps at 415 Volts AC, 13 kiloamps at 500 Volts AC, and 13 kiloamps at 690 Volts AC. The rated ultimate breaking capacity ratings at 50 Hertz line frequency for the 140UE-M7D3-D40 circuit breaker are 100 kiloamps at 220 to 240 Volts AC, 70 kiloamps at 415 Volts AC, 35 kiloamps at 500 Volts AC, and 25 kiloamps at 690 Volts AC.
The internal accessories that are available for the Allen-Bradley 140UE-M7D3-D40 circuit breaker include a shunt trip, undervoltage release, auxiliary shields, alarm contact, and an aux/alarm combination. Numerous external accessories are also available including a plug-in base, phase barriers, a slide bar interlock, a pad-lockable hasp, terminal lugs, terminal covers, end cap kits, a variable depth rotary mechanism, and a flex-cable operating mechanism. The 140UE-M7D3-D40 circuit breaker measures approximately 407 x 210 x 104 millimeters (H x W x D). The function of the 140UE-M7D3-D40 circuit breaker is to protect circuits against overloads, short circuits, and ground faults. Popular applications for this circuit breaker include both main and branch circuit protection in panelboards and switchboards.