DO Supply is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply. Product comes with DO Supply's 1-year warranty
Rockwell Disclaimer: The product is used surplus. DO Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because DO Supply is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. DO Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. DO Supply also makes no representations as to your right to install any such firmware on the product. DO Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Rockwell Disclaimer: The product is used surplus. DO Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because DO Supply is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. DO Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. DO Supply also makes no representations as to your right to install any such firmware on the product. DO Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
DO Supply is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply. Product comes with DO Supply's 1-year warranty
Rockwell Disclaimer: The product is used surplus. DO Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because DO Supply is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. DO Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. DO Supply also makes no representations as to your right to install any such firmware on the product. DO Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Warranty: | 1 year DO Supply Warranty Included |
Shipping: | Worldwide shipping via UPS, DHL, and TNT |
Repairs: | We offer repair service for the 1788-CN2DN. |
Exchange: | Exchange credit for your defective unit available. |
Conditions: | We sell preowned surplus and refurbished parts. |
Part Number | 1788-CN2DN |
Manufacturer: | Rockwell Automation |
Product Type | ControlNet to DeviceNet Linking Device |
Brand: | Allen-Bradley |
Input Power | 24V DC |
Product Description: | ControlNet and DeviceNet linking device |
DeviceNet Power | 24V DC |
Part Number: | 1788-CN2DN |
Enclosure | Open |
Operating Shock | 30G |
Supported Protocols: | ControlNet; DeviceNet |
Isolation Voltage | 30V |
External power supply, Input: | 24 VDC |
ControlNet Connection | RG6 |
External power supply, DeviceNet | 24 VDC |
DeviceNet Connection | 0.52 mm^2 |
ControlNet media: | RG6 |
Power Connection | 0.25-2.5 mm^2 |
Compatible modules: | PLC5; SLC 500; CompactLogix; ControlLogix; POINT I/O; Flex I/O; Series 9000 Photoeye; 855T Stack light, |
UPC | 10612598205513 |
LED status indicators: | Network Status; DeviceNet I/O status; ControlNet A / ControlNet B network indicator; Module status; Linking activity |
UPC | 10662468217887 |
Mounting method: | Mounting method: |
Mounting material: | Zinc-plated, chromate-passivated steel DIN |
Dimensions (H x W x D), approx. | 120 x 200 x 87 mm (4 11/16 x 7 7/8 x 3 7/16 in.) |
Enclosure type rating | None (open-style) |
Part Number | 1788-CN2DN |
Manufacturer: | Rockwell Automation |
Product Type | ControlNet to DeviceNet Linking Device |
Brand: | Allen-Bradley |
Input Power | 24V DC |
Product Description: | ControlNet and DeviceNet linking device |
DeviceNet Power | 24V DC |
Part Number: | 1788-CN2DN |
Enclosure | Open |
Operating Shock | 30G |
Supported Protocols: | ControlNet; DeviceNet |
Isolation Voltage | 30V |
External power supply, Input: | 24 VDC |
ControlNet Connection | RG6 |
External power supply, DeviceNet | 24 VDC |
DeviceNet Connection | 0.52 mm^2 |
ControlNet media: | RG6 |
Power Connection | 0.25-2.5 mm^2 |
Compatible modules: | PLC5; SLC 500; CompactLogix; ControlLogix; POINT I/O; Flex I/O; Series 9000 Photoeye; 855T Stack light, |
UPC | 10612598205513 |
LED status indicators: | Network Status; DeviceNet I/O status; ControlNet A / ControlNet B network indicator; Module status; Linking activity |
UPC | 10662468217887 |
Mounting method: | Mounting method: |
Mounting material: | Zinc-plated, chromate-passivated steel DIN |
Dimensions (H x W x D), approx. | 120 x 200 x 87 mm (4 11/16 x 7 7/8 x 3 7/16 in.) |
Enclosure type rating | None (open-style) |
The 1788-CN2DN is a ControlNet to DeviceNet linking device from Allen-Bradley. This module functions as a bridge device, enabling ControlNet and DeviceNet-enabled devices to communicate and exchange data. Some compatible devices include Allen-Bradley PLC5, SLC 500, CompactLogix, and ControlLogix controllers as well as DeviceNet adapters such as POINT I/O and Flex I/O adapters. It also supports Allen-Bradley’s Series 9000 Photoeye, 855T Stack light, 1792D- VT0D Maxum Block, Bulletin 160 Drive, and other devices that support DeviceNet communication. The 1788-CN2DN operates when wired to a power supply that delivers an output voltage of 18-32 VDC with a nominal supply voltage of 24 VDC. It supports mounting to a zinc-plated, yellow-chrome steel DIN rail and panel. This module comes with a variety of LED status indicators including DeviceNet network Status; DeviceNet I/O status; ControlNet A and ControlNet B network indicator; Module status and linking activity indicator. The 1788-CN2DN is provided with One (1) rotary switch for DeviceNet data rate configuration; and Four (4) DeviceNet node address switches. For ControlNet communication, this module uses an RG6 connector port while for DeviceNet, the recommended cable is 1485C-P1-Cxxx with a wire size of 0.52 mm2 (20 AWG). For establishing power connection, recommended wire size is 0.25…2.5 mm2 (22…14 AWG), solid or stranded copper wire with a minimum insulation rating of 75 °C (167 °F ) or higher and maximum insulation thickness of 1.2 mm (3/64 in.). The 1788-CN2DN has an operating temperature of 0…60 °C (32…140 °F) and a maximum surrounding air temperature requirement of 60 °C (140 °F). The module’s operating shock is 30g for both DIN rail and panel mounting.
The Allen-Bradley 1788-CN2DN linking device is a ControlNet to DeviceNet linking device. The ControlNet network typically consists of HMIs, I/O devices, drives, and Logix processors. The DeviceNet network typically consists of photo eyes and RediStations. The 1788-CN2DN linking device can be used with PLC-5 processors, ControlLogix processors, and SLC-500 processors. The 1788-CN2DN linking device can perform 2 main functions which are the configuration/monitoring and closed-loop control functions.
The 1788-CN2DN linking device is rated for 24 Volts DC and 500 milliamps of input. The cable type required for ControlNet connections is the RG6 cable and the cable type required for the DeviceNet connections is the 20 AWG 1485C-P1-Cxxx cable. Solid or stranded copper cable rated for 22 to 14 AWG should be used for power connections. The dimensions of the device are 120 x 200 x 87 millimeters. The 1788-CN2DN linking device is an open-style device and it complies with the T4A North American temperature code and the T4 IEC temperature code. The operating temperature range for the 1788-CN2DN linking device is from 32 to 140 degrees Fahrenheit and the storage temperature range is from -40 to 185 degrees Fahrenheit. The temperature of the air surrounding the 1788-CN2DN linking device should not exceed 140 degrees Fahrenheit. The ESD immunity ratings for the device are 6 kilovolts of contact discharge and 8 kilovolts of air discharge.
1. What are the supported protocols of the 1788-CN2DN?
The 1788-CN2DN supports ControlNet and DeviceNet protocols.
2. Does the 1788-CN2DN require an external power supply to operate?
Yes. The 1788-CN2DN energies when connected to a 24 VDC power supply.
3. What are the supported mounting methods of the 1788-CN2DN?
The 1788-CN2DN support DIN rail and Panel mounting.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | $173 | ![]() |
Our highly skilled technicians can repair your 1788-CN2DN. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Please refer to the manual for more information about the 1788-CN2DN such as the wiring diagrams, data sheets and migration or obsolescence details.
Revision Part # | Also Known as | Availability |
1788-CN2DN Ser A
|
1788-CN2DN/A, Series A, Rev A | Request Quote |
"The 1788-CN2DN is a specialty communication module from Allen-Bradley. This module enables the linking of ControlNet and DeviceNet networks and supports a variety of devices. This module allows legacy and modern devices to interact and exchange data over Two (2) different protocols. " -DO Supply Tech
Size | |
Input Type | |
Panel Cutout Height | in mm |
Panel Cutout Width | in mm |
Terminal Height | in mm |
Terminal Width | in mm |
Terminal Overall Depth | in mm |
Terminal Mounted Depth | in mm |
Part Number | 1788-CN2DN |
Manufacturer: | Rockwell Automation |
Product Type | ControlNet to DeviceNet Linking Device |
Brand: | Allen-Bradley |
Input Power | 24V DC |
Product Description: | ControlNet and DeviceNet linking device |
DeviceNet Power | 24V DC |
Part Number: | 1788-CN2DN |
Enclosure | Open |
Operating Shock | 30G |
Supported Protocols: | ControlNet; DeviceNet |
Isolation Voltage | 30V |
External power supply, Input: | 24 VDC |
ControlNet Connection | RG6 |
External power supply, DeviceNet | 24 VDC |
DeviceNet Connection | 0.52 mm^2 |
ControlNet media: | RG6 |
Power Connection | 0.25-2.5 mm^2 |
Compatible modules: | PLC5; SLC 500; CompactLogix; ControlLogix; POINT I/O; Flex I/O; Series 9000 Photoeye; 855T Stack light, |
UPC | 10612598205513 |
LED status indicators: | Network Status; DeviceNet I/O status; ControlNet A / ControlNet B network indicator; Module status; Linking activity |
UPC | 10662468217887 |
Mounting method: | Mounting method: |
Mounting material: | Zinc-plated, chromate-passivated steel DIN |
Dimensions (H x W x D), approx. | 120 x 200 x 87 mm (4 11/16 x 7 7/8 x 3 7/16 in.) |
Enclosure type rating | None (open-style) |
Part Number | 1788-CN2DN |
Manufacturer: | Rockwell Automation |
Product Type | ControlNet to DeviceNet Linking Device |
Brand: | Allen-Bradley |
Input Power | 24V DC |
Product Description: | ControlNet and DeviceNet linking device |
DeviceNet Power | 24V DC |
Part Number: | 1788-CN2DN |
Enclosure | Open |
Operating Shock | 30G |
Supported Protocols: | ControlNet; DeviceNet |
Isolation Voltage | 30V |
External power supply, Input: | 24 VDC |
ControlNet Connection | RG6 |
External power supply, DeviceNet | 24 VDC |
DeviceNet Connection | 0.52 mm^2 |
ControlNet media: | RG6 |
Power Connection | 0.25-2.5 mm^2 |
Compatible modules: | PLC5; SLC 500; CompactLogix; ControlLogix; POINT I/O; Flex I/O; Series 9000 Photoeye; 855T Stack light, |
UPC | 10612598205513 |
LED status indicators: | Network Status; DeviceNet I/O status; ControlNet A / ControlNet B network indicator; Module status; Linking activity |
UPC | 10662468217887 |
Mounting method: | Mounting method: |
Mounting material: | Zinc-plated, chromate-passivated steel DIN |
Dimensions (H x W x D), approx. | 120 x 200 x 87 mm (4 11/16 x 7 7/8 x 3 7/16 in.) |
Enclosure type rating | None (open-style) |
The 1788-CN2DN is a ControlNet to DeviceNet linking device from Allen-Bradley. This module functions as a bridge device, enabling ControlNet and DeviceNet-enabled devices to communicate and exchange data. Some compatible devices include Allen-Bradley PLC5, SLC 500, CompactLogix, and ControlLogix controllers as well as DeviceNet adapters such as POINT I/O and Flex I/O adapters. It also supports Allen-Bradley’s Series 9000 Photoeye, 855T Stack light, 1792D- VT0D Maxum Block, Bulletin 160 Drive, and other devices that support DeviceNet communication. The 1788-CN2DN operates when wired to a power supply that delivers an output voltage of 18-32 VDC with a nominal supply voltage of 24 VDC. It supports mounting to a zinc-plated, yellow-chrome steel DIN rail and panel. This module comes with a variety of LED status indicators including DeviceNet network Status; DeviceNet I/O status; ControlNet A and ControlNet B network indicator; Module status and linking activity indicator. The 1788-CN2DN is provided with One (1) rotary switch for DeviceNet data rate configuration; and Four (4) DeviceNet node address switches. For ControlNet communication, this module uses an RG6 connector port while for DeviceNet, the recommended cable is 1485C-P1-Cxxx with a wire size of 0.52 mm2 (20 AWG). For establishing power connection, recommended wire size is 0.25…2.5 mm2 (22…14 AWG), solid or stranded copper wire with a minimum insulation rating of 75 °C (167 °F ) or higher and maximum insulation thickness of 1.2 mm (3/64 in.). The 1788-CN2DN has an operating temperature of 0…60 °C (32…140 °F) and a maximum surrounding air temperature requirement of 60 °C (140 °F). The module’s operating shock is 30g for both DIN rail and panel mounting.
The Allen-Bradley 1788-CN2DN linking device is a ControlNet to DeviceNet linking device. The ControlNet network typically consists of HMIs, I/O devices, drives, and Logix processors. The DeviceNet network typically consists of photo eyes and RediStations. The 1788-CN2DN linking device can be used with PLC-5 processors, ControlLogix processors, and SLC-500 processors. The 1788-CN2DN linking device can perform 2 main functions which are the configuration/monitoring and closed-loop control functions.
The 1788-CN2DN linking device is rated for 24 Volts DC and 500 milliamps of input. The cable type required for ControlNet connections is the RG6 cable and the cable type required for the DeviceNet connections is the 20 AWG 1485C-P1-Cxxx cable. Solid or stranded copper cable rated for 22 to 14 AWG should be used for power connections. The dimensions of the device are 120 x 200 x 87 millimeters. The 1788-CN2DN linking device is an open-style device and it complies with the T4A North American temperature code and the T4 IEC temperature code. The operating temperature range for the 1788-CN2DN linking device is from 32 to 140 degrees Fahrenheit and the storage temperature range is from -40 to 185 degrees Fahrenheit. The temperature of the air surrounding the 1788-CN2DN linking device should not exceed 140 degrees Fahrenheit. The ESD immunity ratings for the device are 6 kilovolts of contact discharge and 8 kilovolts of air discharge.
1. What are the supported protocols of the 1788-CN2DN?
The 1788-CN2DN supports ControlNet and DeviceNet protocols.
2. Does the 1788-CN2DN require an external power supply to operate?
Yes. The 1788-CN2DN energies when connected to a 24 VDC power supply.
3. What are the supported mounting methods of the 1788-CN2DN?
The 1788-CN2DN support DIN rail and Panel mounting.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | $173 | ![]() |
Our highly skilled technicians can repair your 1788-CN2DN. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | $173 | ![]() |
Our highly skilled technicians can repair your 1788-CN2DN. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Please refer to the manual for more information about the 1788-CN2DN such as the wiring diagrams, data sheets and migration or obsolescence details.
Revision Part # | Also Known as | Availability |
1788-CN2DN Ser A
|
1788-CN2DN/A, Series A, Rev A | Request Quote |
"The 1788-CN2DN is a specialty communication module from Allen-Bradley. This module enables the linking of ControlNet and DeviceNet networks and supports a variety of devices. This module allows legacy and modern devices to interact and exchange data over Two (2) different protocols. " -DO Supply Tech