Allen Bradley 1788 Linking Devices 1788-MCHKR

1788-MCHKR

|

The Allen-Bradley 1788-MCHKR is a Mediachecker device. This device is a hand-held, portable device that is used to identify cable failure, check wiring and measure cable lengths of different industrial protocols such as ControlNet, DeviceNet, Data Highway Plus (DH+) and Ethernet. This device is a battery operated device.

Call for an immediate quote
2 Year DO Supply Warranty
Available
Ships from Raleigh, NC
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with DO Supply's 2-year warranty.
Learn more
  • We sell industrial automation parts backed by our 2-year DO Supply Warranty.

  • Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.

  • AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.

  • Repairs and exchanges are available for all automation products.

  • Reseller Options

    Drop shipping, blind shipping, and account shipping with no extra fees.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for 1788-MCHKR

Part Number1788-MCHKR
Product TypeMedia Checker
Manufacturer:Rockwell Automation
Brand:Allen-Bradley
Test supported:Cable Failures / Measure Length
Compatible cables:ControlNet / DeviceNet / DH+ / RIO / Ethernet cables.
Output Interface:2 Line, 16 Character LCD
Input Interface:Enter, Up, Down and Setup
Operating Modes:Off, Test, Length, Wire Map
Connections:One (1) STP / One (1) RJ45 / One (1) Coax
ControlNet cables:RG6 / RG6F / DS3/4
DeviceNet cables:Thick Thin KwikLink
DH+ / RIO cables:1770-CD / 9022 / 9463
Ethernet cables:UTP / FTP
Power Requirements:Two AA size 1.5 V alkaline batteries
Operating Temperature:0 °C to +45 °C
Non-Operating Temperature:20 °C to +60 °C
Input ConnectorsRJ45, DB-9, and BNC
Ethernet Cable Length1-350m
Ethernet Cable Resolution0.5 m
Controlnet Cable Range1-650m
Power2 AA batteries
Typical Battery Life50 hours
Weight354.4 g
Dimensions18.4 cm x 9.8 cm x 4.6 cm
Rockwell Disclaimer: The product is used surplus. DO Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because DO Supply is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. DO Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. DO Supply also makes no representations as to your right to install any such firmware on the product. DO Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

The 1788-MCHKR is a Mediachecker device that is used for identifying cable abnormalities and measure cable lengths different physical mediums used in implementing industrial protocols. This battery operated, portable device can be used to examine ControlNet cables, DeviceNet cables, Data Highway Plus (DH+), Remote I/O and Ethernet cables.

This device is ideally for maintenance and troubleshooting use as it only require a single manpower to test different cables. This mediachecker device checks for split pair or incorrect pairing, miswiring, shorted and open wires on all type of twisted pair cables and Coaxial cables used for Ethernet.

The 1788-MCHKR is delivered as a package that is composed of a carrying case, One (1) resistive adapter cable identifier with a female DB9 connector, Interface cables and adapters, documentation and pair of 1.5VDC alkaline batteries.

This MediaChecker has a Two (2) liner, Sixteen (16) character LCD display. All information related to the device operation is displayed in this output interface. It also has Enter, Up, Down and Setup intended for user interaction and configuration. It also has a rotary backlight adjustment wherein backlight can be set to Turn On and Off or automatically after Sixty (60) seconds.

This device has Four (4) operating modes, specifically OFF, Test, Length, and Wire Map. OFF position deactivates the device, saving battery energy. Test mode examines the attached cable and evaluates the cable by providing a pass or fail summary. Length display the cable length in units of meters or feet and test for anomalies. Wire map is used to display wiring connections such as short and open connection or split pair.

The Allen-Bradley/Rockwell Automation 1788-MCHKR device is supplied as a complete kit which includes a carrying case, one resistive adapter cable identifier with a female DB9 connector, interface cables and adapters, 1 user manual, a single reference card, and 2 AA alkaline batteries. Note that the batteries have a voltage of 1.5 Volts DC each. To prevent damaging the 1788-MCHKR device and to avoid fires, electric shock, and user injury, the MediaChecker device should not be connected to any telephone inputs, equipment, or systems. Additionally, a voltage of over 25 Volts DC should not be applied to any input on the 1788-MCHKR device. The MediaChecker device has input protection circuitry. Therefore, before connecting the 1788-MCHKR device to a cable, it should first be turned on. The Allen-Bradley 1788-MCHKR device has a crystal liquid display (LCD) that displays 16 characters in 2 lines. When there’ more information than can be displayed on 2 lines, an up or down arrow appears on the left side of the display.

Revision Part #Also known as
1788-MCHKR Ser A1788-MCHKR/A, Series A, Rev A
Request a quote