Product image is representative; revision or series may vary. Contact us to request a specific version.
The MVI69E-MBTCP is a Modbus TCP/IP Enhanced Communication Module. This module is developed by ProSoft Technology that is specifically compatible with CompactLogix controlelrs. This module is a single slot module, with I/O size of 60/120/240 - 16 bit integers with available data of 10,000 words. It has One (1) RJ45 communication port that supports 10/100 Base-T Ethernet data rate.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Modbus TCP/IP Enhanced Communication Module |
| Product Line | CompactLogix |
| Part Number | MVI69E-MBTCP |
| Weight | 3.00 lbs (1.36 kg) |
| Available Data | 10,000 words |
| I/O Size | 60/120/240 - 16 bit integers |
| Module width | Single slot |
| Compatible rack | 1769 CompactLogix |
| Floating point data | Floating point data movement supported, including configurable support for Enron, Daniel®, and other implementations |
| Power Supply distance rating | 4 |
| Communication port | One (1) RJ45 interface |
| Data Rate | 10 / 100 Mbps |
| LED indicators | Configuration Status, Application Status, Backplane Connectivity Status, Module Status |
| Operating Temperature | 32° F to 140° F (0° C to 60° C) |
| Storage Temperature | -40° F to 185° F (-40° C to 85° C) |
| Operating Shock | 30 g |
| Relative humidity | 5% to 95% (without condensation) |
| Backplane Current load | 500 mA @ 5.1 VDC |
| Configuration | ProSoft Configuration Builder |
| Modbus Client Connections | 20 |
| Commands per Client Connection | 16 max. |
| Current Load | 500 mA @ 5 VDC |
The MVI69E-MBTCP is a Modbus TCP/IP Enhanced Communication Module. It must be installed with compatible power supply and at least One (1) free slot in the CompactLogix rack.
The MVI69E-MBTCP has power supply distance rating of 4. When used with CompactLogix 1769-L43 and 1769-L45, install the MVI69E-MBTCP on the first Two (2) slots of the 1769 bus. The MVI69E-MBTCP comes with One (1) RJ45 communication port that supports 10/100 Base-T Ethernet data rate. It also requires used of ProSoft Configuration Builder and ProSoft Discovery Service.
The MVI69E-MBTCP supports both Client and Server connectivity. It may be used to interface with a wide variety of MODBUS enabled devices. It has an I/O size of 60/120/240 - 16 bit integers with 10,000 Words of available data. It supports Floating point data movement as well as support for Enron, Daniel, and other Floating point data implementations. It supports MODBUS functions such as 1: Read Coil Status; 2: Read Input Status; 3: Read Holding Register; 4: Read Input Registers; 5: Force (Write) Single Coil; 6: Preset (Write) Single Holding Register; 8: Diagnostics (Slave Only, Responds to Sub function 00); 15: Force (Write) Multiple Coils;16: Preset (Write) Multiple Holding Registers; 17: Report Slave ID (Slave Only); 22: Mask Write Holding Register (Slave Only) and 23: Read/Write Holding registers (Slave only).
This module is shipped with the setup jumper OFF. The acts as an input and output communication module between the Modbus TCP/IP network. The MVI69E-MBTCP communicates with MODBUS compatible devices, acting also as a communication module between the bus network and the CompactLogix backplane. The cable recommended for Ethernet connection is a category 5 or higher. The recommended conditions for the optimum performance of the Prosoft Technologies MVI69E-MBTCP Modbus TCP/IP Enhanced Communication Module are an operating temperature of 0 to 60 degrees Celsius and a relative humidity of 5 to 95%. The Prosoft Technologies MVI69E-MBTCP Modbus TCP/IP Enhanced Communication Module provides LED indicator that shows the module status, the backplane activity, the Ethernet port activity and the configuration. This module needs to be installed on a rack, and after the installation, users need to check that the module is secured enough to avoid trouble integrating the module into the system.
| Revision Part # | Also known as | |
|---|---|---|
| MVI69E-MBTCP Ser A | MVI69E-MBTCP/A, Series A, Rev A | |
| Don't see your particular revision? Contact us now. | ||
Yes, the MVI69E-MBTCP includes a free 2-year DO Supply warranty. You can upgrade to a 3-year warranty at checkout for even more protection.
The MVI69E-MBTCP supports MODBUS TCP communication protocol.
The MVI69E-MBTCP supports 1: Read Coil Status; 2: Read Input Status; 3: Read Holding Register; 4: Read Input Registers; 5: Force (Write) Single Coil; 6: Preset (Write) Single Holding Register; 8: Diagnostics (Slave Only, Responds to Sub function 00); 15: Force (Write) Multiple Coils;16: Preset (Write) Multiple Holding Registers; 17: Report Slave ID (Slave Only); 22: Mask Write Holding Register (Slave Only) and 23: Read/Write Holding registers (Slave only).
The MVI69E-MBTCP supports the 1769 CompactLogix controller platform.
The ProSoft MVI69E-MBTCP Modbus TCP/IP Enhanced Communication Module has a ProSoft Configuration Builder Configuration and a 10,000 Words Available Data. It also has a 60/120/240 - 16 bit integers I/O Size and 20 Modbus Client Connections.