Product image is representative; revision or series may vary. Contact us to request a specific version.
The Allen-Bradley 1756-CN2R is a communication module from the ControlLogix controller platform. This module features Two (2) ControlNet BNC port that supports 5 Mbps transmission speed and One (1) USB communication port that supports 12Mbps data rate. This ControlNet module supports redundant ControlNet topology. Up to 128 Logix connections can be established with this module.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Category | PLCs |
| Product Line | ControlLogix |
| Part Number | 1756-CN2R |
| UPC | 612598324439 |
| Weight | 0.94 lbs (0.43 kg) |
| Module Type | Bridge Module |
| 1756-CN2R | Series |
| Product Description | ControlNet communication module |
| Maximum Nodes | 99 |
| ControlLogix | Module Type |
| Maximum Connections | 131 |
| ControlNet communication module | Location |
| ControlNet Communication Rate | 5 megabits-second |
| Chassis | Backplane Current (5.1 Volts DC) |
| Communication Port | Two (2) ControlNet; One (1) USB |
| Configuration | Redundant |
| 1300 mA | Backplane Current (24 Volts DC) |
| ControlNet Data Transfer speed | 5 Mbps |
| Input Current | 1300 milliamps at 5.1 Volts DC, 3 milliamps at 24 Volts DC |
| 3 mA | Isolation Voltage |
| USB Data Transfer rate | 12 Mbps |
| Thermal Dissipation | 22.9 BTU per Hour |
| 30 Volts Continuous | Power Dissipation (Max) |
| Mounting | Any 1756 Chassis |
| Power Dissipation | 6.7 Watts |
| 6.7 Watts | Enclosure |
| Compatible Power Supply (Standard) | 1756-PA72/C, 1756-PA75/B, 1756-PB72/C, 1756-PB75/B, 1756-PC75/B, 1756-PH75/B |
| Slot width | 1 |
| Open Type | Thermal Dissipation |
| Compatible Power Supply (Redundant) | 1756-PA75R, 1756-PB75R, 1756-PSCA2 |
| 22.9 BTU/hr | Communication Cable |
| Compatible Chassis | 1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17 |
| 1786-RG6 quad shield RG6 coaxial cable | Dimensions |
| Backplane current | 1.3 A at 5.1 VDC; 3 mA at 24VDC |
| 5.51 x 4.41 x 5.71 inches | Operating Temperature |
| 32-140 Fahrenheit (0-60 Celsius) | Chassis |
| 1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17 | Power supply, standard |
| No. of Logix connections | 128 |
| 1756-PA72/C, 1756-PA75/B, 1756-PB72/C, 1756-PB75/B, 1756-PC75/B, 1756-PH75/B | Power supply, redundant |
| Max. no. of connections | 131 |
| 1756-PA75R, 1756-PB75R, 1756-PSCA2 | |
| Maximum number of nodes | 99 |
The Allen-Bradley 1756-CN2R is a ControlLogix communication module that is part of the Logix controller platform. This module is primarily used for establishing connectivity in redundant ControlNet network topology as it features Two (2) BNC ControlNet ports. This module occupies a single sot of the cassis and may be installed to any available slot of standard chassis such as 1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17 and used with standard ControlLogix power supply particularly 1756-PA72/C, 1756-PA75/B, 1756-PB72/C, 1756-PB75/B, 1756-PC75/B, 1756-PH75/B and redundant power supply such as 1756-PA75R, 1756-PB75R, 1756-PSCA2. ControlNet network is a multi-node communication network utilizing a coaxial cable trunk line with nodes connecting at the trunk line using drop cables. This particular module uses 1786-RG6 quad shield RG6 coaxial cable for connection to the network. Up to 5 Mbps transmission speed is supported by the 1756-CN2R. Aside from the dual ControlNet ports, the 1756-CN2R also comes with One (1) USB port that supports a 12 Mbps transmission rate at full speed. It cannot be used for data communication purposes. This module is applicable for implementing Distributed I/O topology as it can cover up to 1000 meters per segment which can be easily extended with the use of repeaters as signal boosters for ControlNet segments longer than 1000 meters. It can be also to communicate with Human Machine Interface (HMI) devices and Supervisory Control and Data Acquisition (SCADA) systems. It supports up to 128 Logix connections and a maximum of 131 communication connections.
The 1756-CN2R ControlNet Connections per Communication Module by Allen-Bradley is a communication module attached to a slot on the ControlLogix Chassis that provides a ControlNet Network through the Common Industrial Protocol (CIP) and a peer-to-peer network for enhanced functions. It has a redundant configuration type and communicates at a rate of 5Mbps over a maximum of 99 nodes. The 1756-CN2R has a maximum of 128 Logix communication connections. It has a draw current of 1300mA at 5.1V DC and one of 3mA at 24V DC and it dissipates 6.6W heat at 22.5 BTU/hr. It has 30V DC isolation voltage with basic insulation tested at 500V for a minute between the ControlNet and the system. The 1756-CN2R has double ControlNet BNC, a ControlNet RJ45, and a single USB 1.1 port for connection and communication with other devices. It comes in an open enclosure type and is designated at the T4 IEC temperature code and at the T4A North American Temperature code. The 1756-CN2R operational temperature ranges between 0 and 60 deg. C (32 and 140 deg. F) at 5-95% non-condensing relative humidity, and it has an operational shock rate of 30G and a maximum vibration of 2G at 10-500Hz.
| Revision Part # | Also known as | |
|---|---|---|
| 1756-CN2R Ser A | 1756-CN2R/A, Series A, Rev A | |
| 1756-CN2R Ser B | 1756-CN2R/B, Series B, Rev B | |
| 1756-CN2R Ser C | 1756-CN2R/C, Series C, Rev C | |
| Don't see your particular revision? Contact us now. | ||
Yes, the 1756-CN2R includes a free 2-year DO Supply warranty. You can upgrade to a 3-year warranty at checkout for even more protection.
The 1756-CN2R has dual ControlNet communication interface.
The 1756-CN2R requires use of 1786-RG6 quad shield RG6 coaxial cable.
Compatible ControlLogix chassis are 1756-A4, 1756-A7, 1756-A10, 1756-A13 and 1756-A17.
Yes. The 1756-CN2R support redundant ControlNet network.
The 1756-CN2R is a single slot module.
Up to 128 Logix connections is supported by the 1756-CN2R.
The Allen-Bradley 1756-CN2R is a ControlNet communication module that is part of the ControlLogix product family. This module has redundant ControlNet ports that supports implementation of linear or redundant ControlNet network topology. Each port is capable of up to 5 mbps transmission speed, up to 128 logix communication connections, 131 connections and up to 99 nodes. This module is installed to a local or remotely located 1756 ControlLogix chassis and draws backplane current amounting to 1300 mA @ 5VDC and 3 mA @ 24VDC.