1756-IA16K

 
 
 
 
 
Rated 4.5 with 13 reviews

top legal disclaimer bottom legal disclaimer
credit cards accepted
better business bureau

1756-IA16K

Revisions: Ser A 
Description: Allen Bradley ControlLogix Digital AC Input Module with 16 Inputs
Available Now
Request a quote for 1756-IA16K

Description: Allen Bradley ControlLogix Digital AC Input Module with 16 Inputs

no auth
no auth mobile
disclaimer
credit cards
better business bureau
Revisions: Ser A 

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 1756-IA16K.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

phone

International
919-205-4392
phone

International
919-205-4392

Rated 4.5 with 13 reviews

    Technical Specifications for 1756-IA16K

ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.1756-IA16
SeriesControlLogix
Module TypeDigital AC Input Module
Inputs16
Input Voltage120 Volts AC
Operating Voltage Range74-132 Volts AC
Input Delay TimeProgrammable 9 or 18 milliseconds
Minimum Operating Current5 milliamperes at 74 Volts AC
Maximum Operating Current13 milliamperes at 132 Volts AC
Maximum Input Current, Off-State2.5 milliamperes
Power Dissipation (Max)5.8 Watts at 60 degrees Celsius
Backplane Current at 5 Volts105 milliamperes
Backplane Current at 24 Volts2 milliamperes
RSLogix 5000 SoftwareVerson 8.02.00 or later
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.1756-IA16
SeriesControlLogix
Module TypeDigital AC Input Module
Inputs16
Input Voltage120 Volts AC
Operating Voltage Range74-132 Volts AC
Input Delay TimeProgrammable 9 or 18 milliseconds
Minimum Operating Current5 milliamperes at 74 Volts AC
Maximum Operating Current13 milliamperes at 132 Volts AC
Maximum Input Current, Off-State2.5 milliamperes
Power Dissipation (Max)5.8 Watts at 60 degrees Celsius
Backplane Current at 5 Volts105 milliamperes
Backplane Current at 24 Volts2 milliamperes
RSLogix 5000 SoftwareVerson 8.02.00 or later

About 1756-IA16K

Coating

FAQ for 1756-IA16K

The Allen-Bradley 1756-IA16K is a part of ControlLogix Digital AC Input Module with 16 (8 points/group) individually-isolated inputs. This module gives off a maximum of 5.8 W at 60 °C of power dissipation and 18.41 BTU/hr of thermal dissipation. The 1756-IA16K uses the 1756-TBNH or the 1756-TBSH as a removable terminal block housing and a user-defined mechanical type of RTB keying. With an open-style type of enclosure, it operates within a temperature range of 0 - 60 °C and has the conformal coating option that covers the assembly with a seal that protects the module from humidity and contaminants (“K” indication).
The 1756-IA16K exhibits a maximum off-state voltage of 20V and maximum off-state current of 2.5 mA. With a maximum inrush current of 250 mA, the 1756-IA16K has a maximum input impedance of 10.15 k at 132V AC, 60 Hz and caters a cyclic update time from 200 s up to 750 ms. Moreover, this ControlLogix Digital AC Input Module has a software configurable type of change of state, ±200 μs time stamp of inputs, and 125V (continuous) isolation voltage. This 120V AC ControlLogix isolated input module operates from 74V AC up to 132V AC and 47- 63 Hz frequency range. The 1756-IA16K’s nominal input voltage is 120V AC and it has a total backplane power of 0.58 W. It draws current at 5.1V of 100 mA and 2 mA at 24V. Moreover, the 1756-IA16K caters an off-to-on maximum hardware delay time of 10 ms and an on-to-off maximum hardware delay time of 8 ms.

Repair Services for 1756-IA16K

Type Lead Time Price Action
Repair Service 2-4 weeks $274cartAdd to Cart
Conformal Coat

Revisions for 1756-IA16K

Please refer to the manual for more information about the 1756-IA16K such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
1756-IA16K Ser A
1756-IA16K/A, Series A, Rev A Request Quote
Common misspellings:
  • l756-IA16K
  • 1756-IAl6K
Technical Specifications
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.1756-IA16
SeriesControlLogix
Module TypeDigital AC Input Module
Inputs16
Input Voltage120 Volts AC
Operating Voltage Range74-132 Volts AC
Input Delay TimeProgrammable 9 or 18 milliseconds
Minimum Operating Current5 milliamperes at 74 Volts AC
Maximum Operating Current13 milliamperes at 132 Volts AC
Maximum Input Current, Off-State2.5 milliamperes
Power Dissipation (Max)5.8 Watts at 60 degrees Celsius
Backplane Current at 5 Volts105 milliamperes
Backplane Current at 24 Volts2 milliamperes
RSLogix 5000 SoftwareVerson 8.02.00 or later
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.1756-IA16
SeriesControlLogix
Module TypeDigital AC Input Module
Inputs16
Input Voltage120 Volts AC
Operating Voltage Range74-132 Volts AC
Input Delay TimeProgrammable 9 or 18 milliseconds
Minimum Operating Current5 milliamperes at 74 Volts AC
Maximum Operating Current13 milliamperes at 132 Volts AC
Maximum Input Current, Off-State2.5 milliamperes
Power Dissipation (Max)5.8 Watts at 60 degrees Celsius
Backplane Current at 5 Volts105 milliamperes
Backplane Current at 24 Volts2 milliamperes
RSLogix 5000 SoftwareVerson 8.02.00 or later
About
Coating
FAQ

The Allen-Bradley 1756-IA16K is a part of ControlLogix Digital AC Input Module with 16 (8 points/group) individually-isolated inputs. This module gives off a maximum of 5.8 W at 60 °C of power dissipation and 18.41 BTU/hr of thermal dissipation. The 1756-IA16K uses the 1756-TBNH or the 1756-TBSH as a removable terminal block housing and a user-defined mechanical type of RTB keying. With an open-style type of enclosure, it operates within a temperature range of 0 - 60 °C and has the conformal coating option that covers the assembly with a seal that protects the module from humidity and contaminants (“K” indication).
The 1756-IA16K exhibits a maximum off-state voltage of 20V and maximum off-state current of 2.5 mA. With a maximum inrush current of 250 mA, the 1756-IA16K has a maximum input impedance of 10.15 k at 132V AC, 60 Hz and caters a cyclic update time from 200 s up to 750 ms. Moreover, this ControlLogix Digital AC Input Module has a software configurable type of change of state, ±200 μs time stamp of inputs, and 125V (continuous) isolation voltage. This 120V AC ControlLogix isolated input module operates from 74V AC up to 132V AC and 47- 63 Hz frequency range. The 1756-IA16K’s nominal input voltage is 120V AC and it has a total backplane power of 0.58 W. It draws current at 5.1V of 100 mA and 2 mA at 24V. Moreover, the 1756-IA16K caters an off-to-on maximum hardware delay time of 10 ms and an on-to-off maximum hardware delay time of 8 ms.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks $274cartAdd to Cart
Conformal Coat
Type Lead Time Price Action
Repair Service 2-4 weeks $274cartAdd to Cart
Conformal Coat
Revisions

Please refer to the manual for more information about the 1756-IA16K such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
1756-IA16K Ser A
1756-IA16K/A, Series A, Rev A Request Quote

Common misspellings:
  • l756-IA16K
  • 1756-IAl6K
PDF