Product image is representative; revision or series may vary. Contact us to request a specific version.
Allen Bradley ControlLogix Isolated Relay Output Module with 16-Point Individually Isolated Outputs
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Category | PLCs |
| Product Line | ControlLogix |
| Part Number | 1756-OW16IK |
| UPC | 887172383670 |
| Weight | 1.00 lbs (0.45 kg) |
| Module Type | Isolated Relay Output Module |
| Outputs | 16-Point Individually Isolated |
| Operating Voltage | 10-265 Volts AC, 5-150 Volts DC |
| Output Current | 2, 0.5, 0.25 Amps |
| Maximum Output Delay Time | 10 milliseconds |
| Contact Output | 13 N.O. |
| Power Dissipation (Max) | 4.5 Watts at 60 Celsius |
| Backplane Current at 5 Volts | 150 milliamps |
| Backplane Current at 24 Volts | 150 milliamps |
| Removeable Terminal Block(s) | 1756-TBCH, 1756-TBS6H |
| Isolation Voltage | 50 Volts Continuous |
| Enclosure | None |
The Allen-Bradley 1756-OW16IK module is a conformally-coated isolated contact module for Allen-Bradley ControlLogix 5580 programmable controllers. The 1756-OW16IK module has 16 normally open individually isolated outputs. The pilot duty is the C300/R150 pilot duty. The operating voltage ranges are from 5 to 125 Volts DC and 10 to 240 Volts AC. The output voltage range is load-dependent: at 1 Amp, the output voltage range is from 5 to 30 Volts DC, at 0.5 Amps, the output is 48 Volts DC, at 0.22 Amps, the output is 125 Volts DC, at 1.5 Amps, the output is 120 Volts AC (at 50 to 60 Hertz), and at 0.75 Amps, the output voltage is 240 Volts AC (at 50 to 60 Hertz).
The current draw of the 1756-OW16IK module at both 5.1 Volts and 24 Volts is 150 milliamps. The power draw from the chassis backplane is 4.4 Watts and the peak power dissipation is 4.5 Watts. The module thermal dissipation is 15.35 BTU per hour. The minimum load current per point is 10 milliamps. The initial contact resistance is 100 milliohms at 6 Volts and 1 Amp. The expected contact life is 300 kilohertz resistive and 100 kilohertz inductive. The 1756-OW16IK module can be used with removable terminal blocks, including the 1756-TBCH and 1756-TBS6H removable terminal blocks. One slot in the rack is required for module installation. The operating temperature range for the 1756-OW16IK module is from 0 to 60 degrees Celsius. The continuous isolation voltage rating is 250 Volts. The module can be installed when the chassis power is applied. However, it is not advisable to do so because an electric arc can occur during the module insertion or removal process which could lead to explosions in hazardous locations.
| Revision Part # | Also known as | |
|---|---|---|
| 1756-OW16IK Ser A | 1756-OW16IK/A, Series A, Rev A | |
| Don't see your particular revision? Contact us now. | ||