Logix5550

 
 
 
 
 
Rated 4.6 with 14 reviews

top legal disclaimer bottom legal disclaimer
credit cards accepted
better business bureau

Logix5550

Revisions: Ser A 
Description: Allen Bradley ControlLogix Logic Controller Module with Open Enclosure
Available Now
Request a quote for Logix5550

Description: Allen Bradley ControlLogix Logic Controller Module with Open Enclosure

no auth
no auth mobile
disclaimer
credit cards
better business bureau
Revisions: Ser A 

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the Logix5550.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

phone

International
919-205-4392
phone

International
919-205-4392

Rated 4.6 with 14 reviews

    Technical Specifications for Logix5550

ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.1756-L1
SeriesControlLogix
Module TypeLogic Controller Module
EnclosureOpen
Isolation Voltage30 Volts Continuous
Operating Temperature32-140 Fahrenheit (0-60 Celsius)
Backplane Current (5Volts)1,200 milliamps
Backplane Current (24 Volts)2.5 milliamps
Power Dissipation (Max)6.19 Watts
Wire Size20 AWG
Dimensions5.51 x 4.41 x 5.71 inches
Operating Temperature32-140 Fahrenheit (0-60 Celsius)
EnclosureNone
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.1756-L1
SeriesControlLogix
Module TypeLogic Controller Module
EnclosureOpen
Isolation Voltage30 Volts Continuous
Operating Temperature32-140 Fahrenheit (0-60 Celsius)
Backplane Current (5Volts)1,200 milliamps
Backplane Current (24 Volts)2.5 milliamps
Power Dissipation (Max)6.19 Watts
Wire Size20 AWG
Dimensions5.51 x 4.41 x 5.71 inches
Operating Temperature32-140 Fahrenheit (0-60 Celsius)
EnclosureNone

About Logix5550

The Allen-Bradley Logix5550 is a processor module in the ControlLogix series of controllers with part number 1756-L1 (Series A). It has 64 KB of user memory and multiple controllers can be installed in one ControlLogix chassis, or one controller can be installed in any slot on a ControlLogix chassis. The memory can be expanded to up to 2 MB with additional memory modules. The Logix5550 has a continuous isolation voltage of 30 V and a maximum power dissipation of 6.19 W. It has a backplane current of 1.2 A at 5V and 2.5 mA at 24V.
The Logix5550 has a Logix CPU and a backplane CPU to divide its resources between them. The 1756-CP3 serial cable is used to connect the controller to the workstation. RSLinx communication software is used to configure the device driver and the RSLogix 5000 programming software to select the controller path. For communication with other devices, it uses various networks like Ethernet/IP, ControlNet, DeviceNet, etc. It can produce (broadcast) and consume (receive) system-shared tags over EtherNet/IP or ControlNet networks.
The Logix5550 controller has a multitasking feature which lets processing time be allocated to different operations in the application. It also contains programs for group data and logic data. It provides routines to encapsulate executable code in a single programming language. The Logix5550 supports Logix5000 programming languages both online and offline. In case of any I/O communication failure, it has an I/O LED that flashes green. It also contains a fault handler for diagnostics. It supports the 1756-BA1 or the 1756-BATM battery which needs to be regularly maintained.

Repair Services for Logix5550

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your ControlLogix 1756-L1. All our repairs come with a 1 Year Warranty. Please contact us for additional information about our repair process.

Revisions for Logix5550

Please refer to the manual for more information about the Logix5550 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
Logix5550 Ser A
Logix5550/A, Series A, Rev A Request Quote
Common misspellings:
  • 1ogix5550
  • L0gix5550
  • Logix555o
Technical Specifications
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.1756-L1
SeriesControlLogix
Module TypeLogic Controller Module
EnclosureOpen
Isolation Voltage30 Volts Continuous
Operating Temperature32-140 Fahrenheit (0-60 Celsius)
Backplane Current (5Volts)1,200 milliamps
Backplane Current (24 Volts)2.5 milliamps
Power Dissipation (Max)6.19 Watts
Wire Size20 AWG
Dimensions5.51 x 4.41 x 5.71 inches
Operating Temperature32-140 Fahrenheit (0-60 Celsius)
EnclosureNone
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.1756-L1
SeriesControlLogix
Module TypeLogic Controller Module
EnclosureOpen
Isolation Voltage30 Volts Continuous
Operating Temperature32-140 Fahrenheit (0-60 Celsius)
Backplane Current (5Volts)1,200 milliamps
Backplane Current (24 Volts)2.5 milliamps
Power Dissipation (Max)6.19 Watts
Wire Size20 AWG
Dimensions5.51 x 4.41 x 5.71 inches
Operating Temperature32-140 Fahrenheit (0-60 Celsius)
EnclosureNone
About

The Allen-Bradley Logix5550 is a processor module in the ControlLogix series of controllers with part number 1756-L1 (Series A). It has 64 KB of user memory and multiple controllers can be installed in one ControlLogix chassis, or one controller can be installed in any slot on a ControlLogix chassis. The memory can be expanded to up to 2 MB with additional memory modules. The Logix5550 has a continuous isolation voltage of 30 V and a maximum power dissipation of 6.19 W. It has a backplane current of 1.2 A at 5V and 2.5 mA at 24V.
The Logix5550 has a Logix CPU and a backplane CPU to divide its resources between them. The 1756-CP3 serial cable is used to connect the controller to the workstation. RSLinx communication software is used to configure the device driver and the RSLogix 5000 programming software to select the controller path. For communication with other devices, it uses various networks like Ethernet/IP, ControlNet, DeviceNet, etc. It can produce (broadcast) and consume (receive) system-shared tags over EtherNet/IP or ControlNet networks.
The Logix5550 controller has a multitasking feature which lets processing time be allocated to different operations in the application. It also contains programs for group data and logic data. It provides routines to encapsulate executable code in a single programming language. The Logix5550 supports Logix5000 programming languages both online and offline. In case of any I/O communication failure, it has an I/O LED that flashes green. It also contains a fault handler for diagnostics. It supports the 1756-BA1 or the 1756-BATM battery which needs to be regularly maintained.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your ControlLogix 1756-L1. All our repairs come with a 1 Year Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your ControlLogix 1756-L1. All our repairs come with a 1 Year Warranty. Please contact us for additional information about our repair process.

Revisions

Please refer to the manual for more information about the Logix5550 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
Logix5550 Ser A
Logix5550/A, Series A, Rev A Request Quote