Description: The Allen-Bradley 1794-L34 is a FlexLogix controller. This controller has 512Kbytes user memory, powered by an external supply voltage of 24VDC. This controller has One (1) serial communication port and supports installation of communication adapters to connect to Ethernet I/P, EeviceNet and ControlNet communication networks.
In Stock Ships Today
Request a quote for 1794-L34

Description: The Allen-Bradley 1794-L34 is a FlexLogix controller. This controller has 512Kbytes user memory, powered by an external supply voltage of 24VDC. This controller has One (1) serial communication port and supports installation of communication adapters to connect to Ethernet I/P, EeviceNet and ControlNet communication networks.

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 1794-L34.
Exchange: Exchange credit for your defective unit available.

To speak to a sales representative for pricing & lead time:


Rated 4.8 with 7 reviews

    Technical Specifications for 1794-L34

ManufacturerRockwell Automation
Thermal Dissipation87BTU/hour @ 19.2V
Power Dissipation25.5W maximum at 19.2V; 20.4W maximum at 24V dc
Isolation Voltage30V dc Qualification tested to withstand 850V dc for 60
Part Number/Catalog No.1794-L34
BrandAllen-Bradley
Product Description:Flex IO Controller
User Memory:512 Kbytes
Nominal power supply voltage:24V dc
Power supply voltage range:19.2-31.2 VDC
Backplane Current:653mA maximum @ 5.1V dc
Extended local I/O cable:1794-CE1 cable (1 foot); 1794-CE3 cable (3 feet)
Mounting:DIN Rail; Panel Mount
DIN Rail type:steel, 35 x 7.55mm DIN rail A-B part number 199-DR1; 46277-3; EN 50022
Product TypeFlexLogix Controller System
Memory512 Kb
Input Voltage24 Volts DC
Input Current 0.85A at 24 Volts DC maximum
Flexbus Current Output653mA at 5.1 Volts DC maximum
Weight0.75 kilograms
Power Connector Torque0.6 to 0.8 N-m
Enclosure Type RatingNone(open-style)
UPC10612598140166
UPC10612598269737
ManufacturerRockwell Automation
Thermal Dissipation87BTU/hour @ 19.2V
Power Dissipation25.5W maximum at 19.2V; 20.4W maximum at 24V dc
Isolation Voltage30V dc Qualification tested to withstand 850V dc for 60
Part Number/Catalog No.1794-L34
BrandAllen-Bradley
Product Description:Flex IO Controller
User Memory:512 Kbytes
Nominal power supply voltage:24V dc
Power supply voltage range:19.2-31.2 VDC
Backplane Current:653mA maximum @ 5.1V dc
Extended local I/O cable:1794-CE1 cable (1 foot); 1794-CE3 cable (3 feet)
Mounting:DIN Rail; Panel Mount
DIN Rail type:steel, 35 x 7.55mm DIN rail A-B part number 199-DR1; 46277-3; EN 50022
Product TypeFlexLogix Controller System
Memory512 Kb
Input Voltage24 Volts DC
Input Current 0.85A at 24 Volts DC maximum
Flexbus Current Output653mA at 5.1 Volts DC maximum
Weight0.75 kilograms
Power Connector Torque0.6 to 0.8 N-m
Enclosure Type RatingNone(open-style)
UPC10612598140166
UPC10612598269737
s

About 1794-L34

The Allen-Bradley 1794-L34 is a FlexLogix controller that is compatible for use with the Flex I/O modular system. This controller is ideal for small and simple applications however, supports installation in a wide variety of industrial applications such as factory and process automation.

The 1794-L34 features an embedded serial communication interface that supports ASCII and DF1 protocol. ASCII is typically used for communicating with barcode readers while DF1 may be used to used with operator terminals such as PanelView Graphic Terminals as well as Supervisory Control and Data Acquisition (SCADA) systems. It may be installed with communication adapters such has the 1788 communication adapters to become compatible with Ethernet, DeviceNet and ControlNet communication networks.

The 1794-L34 comes with an internal user memory amounting to 512 Kbytes. It is powered by an external supply voltage of 24VDC, nominal with acceptable voltage range of 19-31.2 VDC, including 5% ac ripple. It requires a FlexBus current of 653mA maximum @ 5.1V dc and power dissipation of 25.5W maximum at 19.2V and 20.4W maximum at 24V dc while the controllers Thermal dissipation is 87BTU/hour @ 19.2V.

To comply with CSA requirements, a Separated Extra Low Voltage (SELV) power supply such as 1794-PS3 or 1794-PS13 may be used. When terminating power supply input, use #22 to #14 AWG (0.324 to 2.08 sq. mm) stranded wires and tighten connections with 5 to 7 inch-pounds (0.6 to 0.8Nm) Torque.

The embedded serial cable can be custom fabricated however, Allen-Bradley manufactured cables may be used such as 1756-CP3 or 1747-CP3 directly to controller. It may also be interfaced with 1761-NET-AIC for isolation. When interface with the 1761-NET-AIC, applicable serial communication cables are 1761-CBLPM02 and 1761-CBLPA00.

Application installation orientation for this module is either horizontal or vertical mountinh via a panel mount or DIN rail (particularly a 35 x 7.55 millimeters steel DIN rail). The 1794-L34 can handle up to 8 tasks but only 1 can be continuous. This controller supports event tasks, which are consumed tag trigger as well as EVENT instructions. Aside from DeviceNet, EtherNet/IP, and ControlNet communications, the 1794-L34 can also communicate using serial communication, DH-485, and Modbus via ladder routine. 32 connections each can be made over EtherNet/IP and ControlNet.

This controller has a nominal input voltage rating of 24 Volts DC and a range of 19.2 to 31.2 Volts DC that already includes the 5% AC ripple. Its input current is a maximum of 1.33 Amps at 19.2 Volts DC and a maximum of 0.85 Amps at 24 Volts DC. The Flexbus current has a maximum of 653 mA at 5.1 Volts DC and a maximum power dissipation is 25.5 Watts at 19.2 Volts DC and 20.4 Watts at 24 Volts DC. It also has a thermal dissipation of 87 BTU/hour at 19.2 Volts and a non-condensing relative humidity of 5 to 95%. This controller has a non-operating temperature of -40 to 85 degrees Celsius and an operating temperature of 0 to 60 degrees Celsius. The operating vibration of the 1794-L34 controller is 5G at 10 to 500 Hertz and it also has a shock of 30G and 50G, operating and non-operating respectively.

FAQ for 1794-L34

What is the mounting type of 1794-L34?


The 1794-L34 has a compact DIN-Rail mounting type.

Is the battery of 1794-L34 replaceable?


Yes, the battery of 1794-L34 can be replaced by the 1756-BA1.

Can this module be purchased with a warranty?


Yes, the 1794-L34 comes with a free one-year warranty from DO Supply, Inc.

Where can I send the 1794-L34 to be repaired?


DO Supply, Inc. offers a variety of repair services for the 1794-L34.

What is the embedded communication interface of the 1794-L34?


The 1794-L34 has One (1) serial communication interface.

What is the size of the embedded user memory of the 1794-L34?


The 1794-L34 has 512 Kbytes user memory.

Does the 1794-L34 use an internal battery?


Yes. The 1794-L34 uses the 1756-BA1 battery.

Technical Description of 1794-L34

The Allen-Bradley 1794-L34 FlexLogix Controller System has a 512 Kb Memory, a 24 Volt DC Input Voltage, and a 30 Volt DC Isolation Voltage. It also operates with a 20.4 Watts at 24 Volts DC at maximum. Power Dissipation and a 653mA at 5.1 Volts DC at maximum. Flexbus Current Output.

Repair Services for 1794-L34

Type Lead Time Price Action
Repair Service 2-4 weeks $283.84cartAdd to Cart

Our highly skilled technicians can repair your 1794-L34. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions for 1794-L34

Please refer to the manual for more information about the 1794-L34 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
1794-L34 Ser A
1794-L34/A, Series A, Rev A Request Quote
1794-L34/B, Series B, Rev B Request Quote
Common misspellings:
  • l794-L34
  • 179A-L34
  • 1794-134
  • 1794-L3A
  • 1794L34

Reviews for 1794-L34

Internal Review

"The 1794-L34 is a FlexLogix controller that is compatible for use with the Flex I/O module system. This controller comes with an internal memory amounting to 512KB user memory which is considerably higher compared to the 1794-L33 with 64 Kbytes memory. Though this controller is part of the Logix controller platform, it does not come with an Ethernet interface for connection however, optional communication adapters may be installed to allow the controller communicate with different communication networks. " -DO Supply Tech

Dimensions For 1794-L34

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For 1794-L34

Resolutions For 1794-L34

About

Technical Specifications for 1794-L34

ManufacturerRockwell Automation
Thermal Dissipation87BTU/hour @ 19.2V
Power Dissipation25.5W maximum at 19.2V; 20.4W maximum at 24V dc
Isolation Voltage30V dc Qualification tested to withstand 850V dc for 60
Part Number/Catalog No.1794-L34
BrandAllen-Bradley
Product Description:Flex IO Controller
User Memory:512 Kbytes
Nominal power supply voltage:24V dc
Power supply voltage range:19.2-31.2 VDC
Backplane Current:653mA maximum @ 5.1V dc
Extended local I/O cable:1794-CE1 cable (1 foot); 1794-CE3 cable (3 feet)
Mounting:DIN Rail; Panel Mount
DIN Rail type:steel, 35 x 7.55mm DIN rail A-B part number 199-DR1; 46277-3; EN 50022
Product TypeFlexLogix Controller System
Memory512 Kb
Input Voltage24 Volts DC
Input Current 0.85A at 24 Volts DC maximum
Flexbus Current Output653mA at 5.1 Volts DC maximum
Weight0.75 kilograms
Power Connector Torque0.6 to 0.8 N-m
Enclosure Type RatingNone(open-style)
UPC10612598140166
UPC10612598269737
ManufacturerRockwell Automation
Thermal Dissipation87BTU/hour @ 19.2V
Power Dissipation25.5W maximum at 19.2V; 20.4W maximum at 24V dc
Isolation Voltage30V dc Qualification tested to withstand 850V dc for 60
Part Number/Catalog No.1794-L34
BrandAllen-Bradley
Product Description:Flex IO Controller
User Memory:512 Kbytes
Nominal power supply voltage:24V dc
Power supply voltage range:19.2-31.2 VDC
Backplane Current:653mA maximum @ 5.1V dc
Extended local I/O cable:1794-CE1 cable (1 foot); 1794-CE3 cable (3 feet)
Mounting:DIN Rail; Panel Mount
DIN Rail type:steel, 35 x 7.55mm DIN rail A-B part number 199-DR1; 46277-3; EN 50022
Product TypeFlexLogix Controller System
Memory512 Kb
Input Voltage24 Volts DC
Input Current 0.85A at 24 Volts DC maximum
Flexbus Current Output653mA at 5.1 Volts DC maximum
Weight0.75 kilograms
Power Connector Torque0.6 to 0.8 N-m
Enclosure Type RatingNone(open-style)
UPC10612598140166
UPC10612598269737

About 1794-L34

The Allen-Bradley 1794-L34 is a FlexLogix controller that is compatible for use with the Flex I/O modular system. This controller is ideal for small and simple applications however, supports installation in a wide variety of industrial applications such as factory and process automation.

The 1794-L34 features an embedded serial communication interface that supports ASCII and DF1 protocol. ASCII is typically used for communicating with barcode readers while DF1 may be used to used with operator terminals such as PanelView Graphic Terminals as well as Supervisory Control and Data Acquisition (SCADA) systems. It may be installed with communication adapters such has the 1788 communication adapters to become compatible with Ethernet, DeviceNet and ControlNet communication networks.

The 1794-L34 comes with an internal user memory amounting to 512 Kbytes. It is powered by an external supply voltage of 24VDC, nominal with acceptable voltage range of 19-31.2 VDC, including 5% ac ripple. It requires a FlexBus current of 653mA maximum @ 5.1V dc and power dissipation of 25.5W maximum at 19.2V and 20.4W maximum at 24V dc while the controllers Thermal dissipation is 87BTU/hour @ 19.2V.

To comply with CSA requirements, a Separated Extra Low Voltage (SELV) power supply such as 1794-PS3 or 1794-PS13 may be used. When terminating power supply input, use #22 to #14 AWG (0.324 to 2.08 sq. mm) stranded wires and tighten connections with 5 to 7 inch-pounds (0.6 to 0.8Nm) Torque.

The embedded serial cable can be custom fabricated however, Allen-Bradley manufactured cables may be used such as 1756-CP3 or 1747-CP3 directly to controller. It may also be interfaced with 1761-NET-AIC for isolation. When interface with the 1761-NET-AIC, applicable serial communication cables are 1761-CBLPM02 and 1761-CBLPA00.

Application installation orientation for this module is either horizontal or vertical mountinh via a panel mount or DIN rail (particularly a 35 x 7.55 millimeters steel DIN rail). The 1794-L34 can handle up to 8 tasks but only 1 can be continuous. This controller supports event tasks, which are consumed tag trigger as well as EVENT instructions. Aside from DeviceNet, EtherNet/IP, and ControlNet communications, the 1794-L34 can also communicate using serial communication, DH-485, and Modbus via ladder routine. 32 connections each can be made over EtherNet/IP and ControlNet.

This controller has a nominal input voltage rating of 24 Volts DC and a range of 19.2 to 31.2 Volts DC that already includes the 5% AC ripple. Its input current is a maximum of 1.33 Amps at 19.2 Volts DC and a maximum of 0.85 Amps at 24 Volts DC. The Flexbus current has a maximum of 653 mA at 5.1 Volts DC and a maximum power dissipation is 25.5 Watts at 19.2 Volts DC and 20.4 Watts at 24 Volts DC. It also has a thermal dissipation of 87 BTU/hour at 19.2 Volts and a non-condensing relative humidity of 5 to 95%. This controller has a non-operating temperature of -40 to 85 degrees Celsius and an operating temperature of 0 to 60 degrees Celsius. The operating vibration of the 1794-L34 controller is 5G at 10 to 500 Hertz and it also has a shock of 30G and 50G, operating and non-operating respectively.

FAQ for 1794-L34

What is the mounting type of 1794-L34?


The 1794-L34 has a compact DIN-Rail mounting type.

Is the battery of 1794-L34 replaceable?


Yes, the battery of 1794-L34 can be replaced by the 1756-BA1.

Can this module be purchased with a warranty?


Yes, the 1794-L34 comes with a free one-year warranty from DO Supply, Inc.

Where can I send the 1794-L34 to be repaired?


DO Supply, Inc. offers a variety of repair services for the 1794-L34.

What is the embedded communication interface of the 1794-L34?


The 1794-L34 has One (1) serial communication interface.

What is the size of the embedded user memory of the 1794-L34?


The 1794-L34 has 512 Kbytes user memory.

Does the 1794-L34 use an internal battery?


Yes. The 1794-L34 uses the 1756-BA1 battery.

Technical Description of 1794-L34

The Allen-Bradley 1794-L34 FlexLogix Controller System has a 512 Kb Memory, a 24 Volt DC Input Voltage, and a 30 Volt DC Isolation Voltage. It also operates with a 20.4 Watts at 24 Volts DC at maximum. Power Dissipation and a 653mA at 5.1 Volts DC at maximum. Flexbus Current Output.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks $283.84cartAdd to Cart

Our highly skilled technicians can repair your 1794-L34. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks $283.84cartAdd to Cart

Our highly skilled technicians can repair your 1794-L34. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions

Please refer to the manual for more information about the 1794-L34 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
1794-L34 Ser A
1794-L34/A, Series A, Rev A Request Quote
1794-L34/B, Series B, Rev B Request Quote

Common misspellings:
  • l794-L34
  • 179A-L34
  • 1794-134
  • 1794-L3A
  • 1794L34
PDF
Reviews

Reviews for 1794-L34

Internal Review

"The 1794-L34 is a FlexLogix controller that is compatible for use with the Flex I/O module system. This controller comes with an internal memory amounting to 512KB user memory which is considerably higher compared to the 1794-L33 with 64 Kbytes memory. Though this controller is part of the Logix controller platform, it does not come with an Ethernet interface for connection however, optional communication adapters may be installed to allow the controller communicate with different communication networks. " -DO Supply Tech