Description: The Allen-Bradley 1794-OF4I is a Flex IO isolated analog output module. This module has Four (4) isolated analog output channels. It provides output current signals such as 4-20 mA, 0-20 mA and Voltage signals such as ±10VDC; 0-10VDC; +/- 5VDC and 0-5VDC. It is compatible for use with Flex I/O terminal bases such as 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3T, 1794-TB3TS, 1794-TBN. It is compatible with any 1794 Flex IO adapters to implement distributed I/O application.
In Stock Ships Today
Request a quote for 1794-OF4I

Description: The Allen-Bradley 1794-OF4I is a Flex IO isolated analog output module. This module has Four (4) isolated analog output channels. It provides output current signals such as 4-20 mA, 0-20 mA and Voltage signals such as ±10VDC; 0-10VDC; +/- 5VDC and 0-5VDC. It is compatible for use with Flex I/O terminal bases such as 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3T, 1794-TB3TS, 1794-TBN. It is compatible with any 1794 Flex IO adapters to implement distributed I/O application.

top legal disclaimer
disclaimer
credit cards
better business bureau
Revisions: Ser A 

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 1794-OF4I.
Exchange: Exchange credit for your defective unit available.

To speak to a sales representative for pricing & lead time:


Rated 4.2 with 11 reviews

    Technical Specifications for 1794-OF4I

ManufacturerRockwell Automation
Update Rate2.5/5.0 ms all channels
Conversion TypeDigital to Analog Converter
Resolution15 bits plus sign
Part Number/Catalog No.1794-OF4I
BrandAllen-Bradley
Product Description:Flex IO High Output Module
No. of outputs:Four (4) Isolated
Output type:4-20 mA, 0-20 mA and ±10VDC; 0-10VDC; +/- 5VDC and 0-5VDC
Voltage Resolution0.320 mV/cnt
Current resolution0.656 mA/cnt
Step response to 63% of full scale< 25 s
Terminal base:1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3T, 1794- TB3TS, 1794-TBN
External DC supply, nom:24V DC
External DC supply range:19.2…31.2V DC (includes 5% AC ripple)
Mounting:DIN Rail
Operating Temperature:0 to 55 C (32 to 131 F)
Storage Temperature:–40…85 °C (–40…185 °F)
Vibration:5g @ 10 to 500 Hz
Operating Shock:30 g
Product TypeFlex I/O Isolated Output Analog Module
Outputs4 Isolated
Current Load on Voltage Output3mA max.
FlexBus Current50mA
Isolation Voltage120V Continuous
Output Current Terminal4-20mA
Output Voltage Terminal +/- 10V
Thermal Dissipation16 BTU/hr. @ 31.2V DC max.
UPC10612598171580
ManufacturerRockwell Automation
Update Rate2.5/5.0 ms all channels
Conversion TypeDigital to Analog Converter
Resolution15 bits plus sign
Part Number/Catalog No.1794-OF4I
BrandAllen-Bradley
Product Description:Flex IO High Output Module
No. of outputs:Four (4) Isolated
Output type:4-20 mA, 0-20 mA and ±10VDC; 0-10VDC; +/- 5VDC and 0-5VDC
Voltage Resolution0.320 mV/cnt
Current resolution0.656 mA/cnt
Step response to 63% of full scale< 25 s
Terminal base:1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3T, 1794- TB3TS, 1794-TBN
External DC supply, nom:24V DC
External DC supply range:19.2…31.2V DC (includes 5% AC ripple)
Mounting:DIN Rail
Operating Temperature:0 to 55 C (32 to 131 F)
Storage Temperature:–40…85 °C (–40…185 °F)
Vibration:5g @ 10 to 500 Hz
Operating Shock:30 g
Product TypeFlex I/O Isolated Output Analog Module
Outputs4 Isolated
Current Load on Voltage Output3mA max.
FlexBus Current50mA
Isolation Voltage120V Continuous
Output Current Terminal4-20mA
Output Voltage Terminal +/- 10V
Thermal Dissipation16 BTU/hr. @ 31.2V DC max.
UPC10612598171580
s

About 1794-OF4I

The Allen-Bradley 1794-OF4I is a FLEX I/O analog module. It has 4 isolated analog outputs that is compatible with several terminal base units, namely the 1794-TBT, 1794-TB3, 1794-TB3TS, 1794-TB3S, 1794-TBNF, and the 1794-TBN. It can be mounted using a DIN rail or a panel, it has an open enclosure, and it measures 3.7 x 2.6 x 3.7 inches.

The external DC voltage range of the 1794-OF4I module is 19.2 to 31.2 Volts DC, including the 5% AC ripple. It also has an external DC power supply current of 210 mA at 24 Volts DC. Its maximum overload is 30 Volts or 32 mA continuous in one channel at a time. This module has a maximum 3 mA current load on voltage output and a 0 to 750 resistive load on voltage output. Its output current ranges are 4 to 20 mA and 0 to 20 mA. Both of these ranges are user-configurable. The module's output voltage varies from +/-10 Volts, +/-5 Volts, 0 to 10 Volts, and 0 to 5 Volts, all of which are also user-configurable. Both the voltage and current terminals have 0 output until the module is configured.

The 1794-OF4I has a maximum power dissipation of 4.7 W at 31.2 Volts DC and a maximum thermal dissipation of 16 BTU/hour at 31.2 Volts DC. The module's isolation voltage is dependent on the terminal base unit it is connected to. It has an isolation rating of 250 Volts continuous when using a 1794-TBN base unit and 120 Volts continuous when using other compatible base units. The FlexBus voltage of the module is 5 Volts DC, while the FlexBus current is 50 mA. It has a resolution of 15 bits + sign, 0.320 mV/cnt (voltage), and 0.656 mA/cnt (current). It also has an update rate of 2.5 or 5 milliseconds for all channels and a <25 µs step response at 63% of full scale. Both the voltage and current terminals have an absolute accuracy of 0.1% full scale at 25 degrees Celsius but they have different accuracy drifts with temperature, since it is 0.0012% full scale per degree Celsius for the voltage terminal and 0.0025% full scale per degree Celsius for the current terminal. The conversion type for the 1794-OF4I is digital-to-analog.

This module has digital to analog (DAC) conversion resolution of 15 bits plus sign or 0.320 mV/cnt for Voltage signal and for Current signal 0.656 mA/cnt. This module has output signal update rate of 2.5 ms or 5.0 ms on all channels which may be configured to all channels. The module’s step response to 63% full scale is < 25 s with current load on voltage output of 3 mA.

The module’s absolute accuracy is 0.1% full scale @ 25 °C for both voltage and current terminal with accuracy drift of 0.0012% full scale/°C for voltage and 0.0025% full scale/°C for current. This module is factory calibrated and provides an option to manually calibrated if necessary. It has a maximum overload of 30V continuous or 32 mA continuous, one channel at a time.

The 1794-OF4I is compatible for use with terminal base units such as 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3T, 1794-TB3TS, 1794-TBN. It requires a FlexBus voltage of 5VDC and FlexBus current of 50 mA. For external power supply, nominal supply voltage is 24VDC with applicable voltage range of 19.2-31.2 VDC.

The 1794-OF4I is mounted to a DIN rail or directly to the enclosure sub-panel. It may be used with any available Flex I/O communication adapter and approved for use in hazardous locations.

FAQ for 1794-OF4I

What is the data format used with the 1794-OF4I Isolated Output Analog Module?


The 1794-OF4I Isolated Output Analog Module uses four data formats: binary, offset binary, 2's complement, 2's complement percent.

When the 1794-OF4I Isolated Output Analog Module is processing data, what is the conversion type?


The 1794-OF4I Isolated Output Analog Module uses a digital-to-analog converter.

What are the output current and voltage rates for the 1794-OF4I Isolated Output Analog Module?


The output current and voltage rates are user configurable on the 1794-OF4I Isolated Output Analog Module. Until the rates have been configured, no output will occur.

What are module locations that the 1794-OF4I Isolated Output Analog Module is compatible with?


The 1794-OF4I Isolated Output Analog Module is compatible with 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3T, 1794-TB3TS, or 1794-TBN.

Is the 1794-OF4I Isolated Output Analog Module calibrated?


Yes, the 1794-OF4I Isolated Output Analog Module is factory calibrated but can be recalibrated when necessary.

What is the price of the 1794-OF4I Isolated Output Analog Module?


Submit a quote request, send us an email, or call 800-730-0292 for our best price.

Where can I find repair services for the 1794-OF4I Isolated Output Analog Module?


DO Supply offers repair services for the 1794-OF4I Isolated Output Analog Module. For more information or to request a repair quote, please click here.

Does the 1794-OF4I comes with individually isolated channels?


Yes. It has Four (4) individually isolated output channels.

What are the output signal ranges of the 1794-OF4I?


The 1794-OF4I has an output signal ranges of 4-20 mA, 0-20 mA and ±10VDC; 0-10VDC; +/- 5VDC and 0-5VDC.

What is the external supply voltage requirement of the 1794-OF4I?


The 1794-OF4I requires 24V DC 19.2…31.2V DC (includes 5% AC ripple).

Technical Description of 1794-OF4I

The Allen-Bradley 1794-OF4I Flex I/O Isolated Output Analog Module has 4 Isolated Outputs, a 15 bits Resolution, and a Digital-to-Analog Converter Conversion Type. It also operates with a 3mA max. Current Load on Voltage Output and a 50mA FlexBus Current.

Repair Services for 1794-OF4I

Type Lead Time Price Action
Repair Service 2-4 weeks $385.89cartAdd to Cart

Our highly skilled technicians can repair your 1794-OF4I. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions for 1794-OF4I

Please refer to the manual for more information about the 1794-OF4I such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
1794-OF4I Ser A
1794-OF4I/A, Series A, Rev A Request Quote
Common misspellings:
  • l794-OF4I
  • 179A-OF4I
  • 1794-0F4I
  • 1794-OFAI
  • 1794OF4I

Reviews for 1794-OF4I

Internal Review

"The 1794-OF4I is an analog output module. This module generates 4-20 mA, 0-20 mA and ±10VDC; 0-10VDC; +/- 5VDC and 0-5VDC analog output signals. The main advantage of using this module is that it provides individually isolated output channels, allowing the module to operate even if there are faulty channels present to the module. " -DO Supply Tech

Dimensions For 1794-OF4I

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For 1794-OF4I

Resolutions For 1794-OF4I

About

Technical Specifications for 1794-OF4I

ManufacturerRockwell Automation
Update Rate2.5/5.0 ms all channels
Conversion TypeDigital to Analog Converter
Resolution15 bits plus sign
Part Number/Catalog No.1794-OF4I
BrandAllen-Bradley
Product Description:Flex IO High Output Module
No. of outputs:Four (4) Isolated
Output type:4-20 mA, 0-20 mA and ±10VDC; 0-10VDC; +/- 5VDC and 0-5VDC
Voltage Resolution0.320 mV/cnt
Current resolution0.656 mA/cnt
Step response to 63% of full scale< 25 s
Terminal base:1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3T, 1794- TB3TS, 1794-TBN
External DC supply, nom:24V DC
External DC supply range:19.2…31.2V DC (includes 5% AC ripple)
Mounting:DIN Rail
Operating Temperature:0 to 55 C (32 to 131 F)
Storage Temperature:–40…85 °C (–40…185 °F)
Vibration:5g @ 10 to 500 Hz
Operating Shock:30 g
Product TypeFlex I/O Isolated Output Analog Module
Outputs4 Isolated
Current Load on Voltage Output3mA max.
FlexBus Current50mA
Isolation Voltage120V Continuous
Output Current Terminal4-20mA
Output Voltage Terminal +/- 10V
Thermal Dissipation16 BTU/hr. @ 31.2V DC max.
UPC10612598171580
ManufacturerRockwell Automation
Update Rate2.5/5.0 ms all channels
Conversion TypeDigital to Analog Converter
Resolution15 bits plus sign
Part Number/Catalog No.1794-OF4I
BrandAllen-Bradley
Product Description:Flex IO High Output Module
No. of outputs:Four (4) Isolated
Output type:4-20 mA, 0-20 mA and ±10VDC; 0-10VDC; +/- 5VDC and 0-5VDC
Voltage Resolution0.320 mV/cnt
Current resolution0.656 mA/cnt
Step response to 63% of full scale< 25 s
Terminal base:1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3T, 1794- TB3TS, 1794-TBN
External DC supply, nom:24V DC
External DC supply range:19.2…31.2V DC (includes 5% AC ripple)
Mounting:DIN Rail
Operating Temperature:0 to 55 C (32 to 131 F)
Storage Temperature:–40…85 °C (–40…185 °F)
Vibration:5g @ 10 to 500 Hz
Operating Shock:30 g
Product TypeFlex I/O Isolated Output Analog Module
Outputs4 Isolated
Current Load on Voltage Output3mA max.
FlexBus Current50mA
Isolation Voltage120V Continuous
Output Current Terminal4-20mA
Output Voltage Terminal +/- 10V
Thermal Dissipation16 BTU/hr. @ 31.2V DC max.
UPC10612598171580

About 1794-OF4I

The Allen-Bradley 1794-OF4I is a FLEX I/O analog module. It has 4 isolated analog outputs that is compatible with several terminal base units, namely the 1794-TBT, 1794-TB3, 1794-TB3TS, 1794-TB3S, 1794-TBNF, and the 1794-TBN. It can be mounted using a DIN rail or a panel, it has an open enclosure, and it measures 3.7 x 2.6 x 3.7 inches.

The external DC voltage range of the 1794-OF4I module is 19.2 to 31.2 Volts DC, including the 5% AC ripple. It also has an external DC power supply current of 210 mA at 24 Volts DC. Its maximum overload is 30 Volts or 32 mA continuous in one channel at a time. This module has a maximum 3 mA current load on voltage output and a 0 to 750 resistive load on voltage output. Its output current ranges are 4 to 20 mA and 0 to 20 mA. Both of these ranges are user-configurable. The module's output voltage varies from +/-10 Volts, +/-5 Volts, 0 to 10 Volts, and 0 to 5 Volts, all of which are also user-configurable. Both the voltage and current terminals have 0 output until the module is configured.

The 1794-OF4I has a maximum power dissipation of 4.7 W at 31.2 Volts DC and a maximum thermal dissipation of 16 BTU/hour at 31.2 Volts DC. The module's isolation voltage is dependent on the terminal base unit it is connected to. It has an isolation rating of 250 Volts continuous when using a 1794-TBN base unit and 120 Volts continuous when using other compatible base units. The FlexBus voltage of the module is 5 Volts DC, while the FlexBus current is 50 mA. It has a resolution of 15 bits + sign, 0.320 mV/cnt (voltage), and 0.656 mA/cnt (current). It also has an update rate of 2.5 or 5 milliseconds for all channels and a <25 µs step response at 63% of full scale. Both the voltage and current terminals have an absolute accuracy of 0.1% full scale at 25 degrees Celsius but they have different accuracy drifts with temperature, since it is 0.0012% full scale per degree Celsius for the voltage terminal and 0.0025% full scale per degree Celsius for the current terminal. The conversion type for the 1794-OF4I is digital-to-analog.

This module has digital to analog (DAC) conversion resolution of 15 bits plus sign or 0.320 mV/cnt for Voltage signal and for Current signal 0.656 mA/cnt. This module has output signal update rate of 2.5 ms or 5.0 ms on all channels which may be configured to all channels. The module’s step response to 63% full scale is < 25 s with current load on voltage output of 3 mA.

The module’s absolute accuracy is 0.1% full scale @ 25 °C for both voltage and current terminal with accuracy drift of 0.0012% full scale/°C for voltage and 0.0025% full scale/°C for current. This module is factory calibrated and provides an option to manually calibrated if necessary. It has a maximum overload of 30V continuous or 32 mA continuous, one channel at a time.

The 1794-OF4I is compatible for use with terminal base units such as 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3T, 1794-TB3TS, 1794-TBN. It requires a FlexBus voltage of 5VDC and FlexBus current of 50 mA. For external power supply, nominal supply voltage is 24VDC with applicable voltage range of 19.2-31.2 VDC.

The 1794-OF4I is mounted to a DIN rail or directly to the enclosure sub-panel. It may be used with any available Flex I/O communication adapter and approved for use in hazardous locations.

FAQ for 1794-OF4I

What is the data format used with the 1794-OF4I Isolated Output Analog Module?


The 1794-OF4I Isolated Output Analog Module uses four data formats: binary, offset binary, 2's complement, 2's complement percent.

When the 1794-OF4I Isolated Output Analog Module is processing data, what is the conversion type?


The 1794-OF4I Isolated Output Analog Module uses a digital-to-analog converter.

What are the output current and voltage rates for the 1794-OF4I Isolated Output Analog Module?


The output current and voltage rates are user configurable on the 1794-OF4I Isolated Output Analog Module. Until the rates have been configured, no output will occur.

What are module locations that the 1794-OF4I Isolated Output Analog Module is compatible with?


The 1794-OF4I Isolated Output Analog Module is compatible with 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3T, 1794-TB3TS, or 1794-TBN.

Is the 1794-OF4I Isolated Output Analog Module calibrated?


Yes, the 1794-OF4I Isolated Output Analog Module is factory calibrated but can be recalibrated when necessary.

What is the price of the 1794-OF4I Isolated Output Analog Module?


Submit a quote request, send us an email, or call 800-730-0292 for our best price.

Where can I find repair services for the 1794-OF4I Isolated Output Analog Module?


DO Supply offers repair services for the 1794-OF4I Isolated Output Analog Module. For more information or to request a repair quote, please click here.

Does the 1794-OF4I comes with individually isolated channels?


Yes. It has Four (4) individually isolated output channels.

What are the output signal ranges of the 1794-OF4I?


The 1794-OF4I has an output signal ranges of 4-20 mA, 0-20 mA and ±10VDC; 0-10VDC; +/- 5VDC and 0-5VDC.

What is the external supply voltage requirement of the 1794-OF4I?


The 1794-OF4I requires 24V DC 19.2…31.2V DC (includes 5% AC ripple).

Technical Description of 1794-OF4I

The Allen-Bradley 1794-OF4I Flex I/O Isolated Output Analog Module has 4 Isolated Outputs, a 15 bits Resolution, and a Digital-to-Analog Converter Conversion Type. It also operates with a 3mA max. Current Load on Voltage Output and a 50mA FlexBus Current.
Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks $385.89cartAdd to Cart

Our highly skilled technicians can repair your 1794-OF4I. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks $385.89cartAdd to Cart

Our highly skilled technicians can repair your 1794-OF4I. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions

Please refer to the manual for more information about the 1794-OF4I such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
1794-OF4I Ser A
1794-OF4I/A, Series A, Rev A Request Quote

Common misspellings:
  • l794-OF4I
  • 179A-OF4I
  • 1794-0F4I
  • 1794-OFAI
  • 1794OF4I
PDF
Reviews

Reviews for 1794-OF4I

Internal Review

"The 1794-OF4I is an analog output module. This module generates 4-20 mA, 0-20 mA and ±10VDC; 0-10VDC; +/- 5VDC and 0-5VDC analog output signals. The main advantage of using this module is that it provides individually isolated output channels, allowing the module to operate even if there are faulty channels present to the module. " -DO Supply Tech