Allen Bradley IEC 100 Contactors 100-D110T11

Product image is representative; revision or series may vary. Contact us to request a specific version.

100-D110T11

|

The Allen-Bradley/Rockwell Automation 100-D110T11 Bulletin 100-D contactor is a non-reversing contactor and it comes with 3 main contacts which are power poles. This contactor can be mounted on a panel and it operates with a current rating of 110 Amps at 60 degrees Celsius. This contactor includes one N.O. and one N.C. auxiliary contact.

In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Rockwell Disclaimer: The product is used surplus. DO Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because DO Supply is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. DO Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. DO Supply also makes no representations as to your right to install any such firmware on the product. DO Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Technical specifications for 100-D110T11

ManufacturerAllen Bradley
CategoryPLCs
Product LineIEC 100 Contactors
Part Number100-D110T11
Weight3.00 lbs (1.36 kg)
Type of ComponentContactor
Operating ModeNon-Reversing
Poles3
Voltage TypeStandard AC
Voltage Range240-277 Volts AC
Frequency50-60 Hz
Current at 40 degrees Celsius160 A
Current at 60 degrees Celsius110 A
Auxiliary Contacts1 N.O., 1 N.C.
PLC InterfaceOptional

The 100-D110T11 non-reversing is a contactor that comes from the Bulletin 100-D/104-D series of reversing and non-reversing contactors by Allen-Bradley/Rockwell Automation. This contactor is one of the most compact contactors available in the industry. This contactor can be used in different applications, being the most common applications are safety applications that require feedback and hazardous motion load applications that contain energy isolating switchgear. The Allen-Bradley/Rockwell Automation 100-D110T11 contactor comes with one normally open and one normally closed auxiliary contact. These contacts give the contactor the mirror contact design that comes embedded in it. This feature helps to provide reliable indications about the status of the power poles which are the main contacts. When these poles are affected, the normally closed auxiliary contact will not modify its state, because it will remain isolated in the mirror contact setup.

Some of the key features that are included with the Allen-Bradley/Rockwell Automation Bulletin 100-D series 100-D110T11 contactor are an integrated PLC interface, a low power pick-up rating, and a low power hold-in rating, and the use of a wide voltage range. The voltage rating that is used by this contactor varies according to the frequency rating. With a frequency range of 50 to 60 Hertz, the voltage that is applied will range from 240 to 277 Volts AC. The Allen-Bradley/Rockwell Automation 100-D110T11 contactor operates with 3 power poles. This contactor is meant to be installed on a panel only. Since it has a compact design, it is somewhat easy to find a suitable installation location for it. It is not recommended to operate the contactor at its full rating at temperatures above 60 degrees Celsius. It can operate at up to 70 degrees Celsius if its current is derated.