Product image is representative; revision or series may vary. Contact us to request a specific version.
The Allen-Bradley 100-D210EZY00 Bulletin 100-D contactor has a rated breaking current of 210 Amps. It also has an electronic DC coil with an integrated PLC interface. The 100-D210EZY00 contactor comes with an IP 20 rated enclosure and an operating temperature range of -25 to 60 degrees Celsius.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Category | PLCs |
| Product Line | IEC 100 Contactors |
| Part Number | 100-D210EZY00 |
| Weight | 3.00 lbs (1.36 kg) |
| Description | DC-Operated Contactor |
| Current Rating | 210 Amps |
| Coil Type | Standard DC Electronic Coil |
| Coil Voltage | 48 to 72 Volts DC |
| PLC Interface | Yes |
| Number of Poles | 3 |
| Terminal Type | Bolt-in Type |
| Auxiliary Contacts | None |
| Protection Class | IP 20 |
The Allen-Bradley 100-D210EZY00 Bulletin 100-D contactor has an electronic type of DC-controlled coil with an integrated PLC interface. The coil voltage range is between 48 Volts DC and 72 Volts DC, and the coil has a nominal signal voltage rating of 24 Volts DC at 15 milliamps. The 100-D210EZY00 contactor features a low switching rating that allows for direct wiring to a PLC without interposing relay circuits. The 100-D210EZY00 contactor has an S1 switch in addition to its standard A1 and A2 coil terminals for PLC wiring. Direct integration into a PLC system allows for the remote actuation of coil contacts from a PLC CPU or an operator interface device. The 100-D210EZY00 contactor is supplied without an auxiliary contact or a terminal lug kit. However, the operators can order up to 4 snap-in auxiliary contacts which can be easily mounted on the side of the contactor.
The Allen-Bradley 100-D210EZY00 Bulletin 100-D contactor supports direct 3-phase wiring to a power source. It has 3 main power contacts on the main circuit. These contacts are of the Normally Open (NO) contact type and they all have flat types of terminals that support bolt-in connections. The 100-D210EZY00 contactor accepts a 3-phase external AC power supply. It has a rated operating range of 230 Volts AC to 690 Volts AC at a 50 to 60 frequency range. The 100-D210EZY00 contactor has a rated operating current rating of 210 Amps at 400 Volts AC and a rated operating current rating of 350 Amps at 690 Volts AC. It has a maximum output power rating of 125 kilowatts at 415 Volts AC. The 100-D210EZY00 contactor supports cabinet installation.