The Allen-Bradley 104-E116KD22 Contactor is a 3-pole electronic reversing contactor from the IEC 104 Contactors series. The 104-E116KD22 Contactor has an operating voltage range from 115 to 575 Volts AC and 24 to 440 Volts DC. Its electronic coil has Class F insulation.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Category | PLCs |
| Product Line | IEC 104 Contactors |
| Part Number | 104-E116KD22 |
| Weight | 50.00 lbs (22.68 kg) |
| Description | AC/DC-Operated Contactor |
| Voltage Range | 115 to 575 Volts AC, 24 to 440 Volts DC |
| Current Rating | 116 Amps |
| Coil Type | Standard AC/DC Type Electronic Coil |
| Coil Voltage | 100 to 250 Volts AC/DC |
| PLC Interface | None |
| Number of Poles | 3 |
| Terminal Type | Bolt Type |
| Auxiliary Contact | 1 Normally Open (NO) and 1 Normally Closed (NC) |
| Protection Class | IP2X |
The Allen-Bradley 104-E116KD22 Reversing AC/DC Contactor is an IEC 104 series contactor from the Bulletin 104-E contactor family. This contactor series offers contactors with significantly reduced sizes and lower power consumption ratings to save panel space and operation costs. The 104-E116KD22 Contactor is supplied with a standard AC/DC electronic coil with a rated switching actuation voltage range of 100 to 250 Volts AC/DC (with 50/60 Hertz frequency for the AC voltage). This coil uses its wide voltage range to accommodate a wide range of applications and it uses its lower power consumption rates to save energy and operation costs. The 104-E116KD22 Contactor has Class F insulation for its electronic coil, and it also provides surge suppression to reduce downtime. The 104-E116KD22 Contactor has a 3-pole main contact for wiring to a 3-phase power supply. A mechanical interlock can be used to connect 2 contactors like the 104-E116KD22 Contactor together.
The Allen-Bradley 104-E116KD22 Reversing AC/DC Contactor from the IEC 104 Contactors series also has 2 side-mounted, snap-in, low-power auxiliary contacts (1 normally closed and 1 normally open) for feedback circuits. The 104-E116KD22 Contactor offers a simplified field-through wiring design with bolt-in type terminals for quick and easy wiring. It accepts 3-phase AC input or direct DC input. The 104-E116KD22 Contactor can be wired directly to a 3-phase motor without additional relays. It has an acceptable operating voltage range of 115 to 575 Volts AC (3-phase, at 50/60 Hertz) or 24 to 440 Volts DC, and a maximum current rating of 116 Amps in AC-3 applications at the nominal input rating. The 104-E116KD22 Contactor provides a circuit isolation voltage of up to 690 Volts AC and a maximum impulse withstand voltage rating of 6000 Volts.