The 1784-KTXD communication card is an Allen-Bradley/Rockwell Automation PLC 5 series NetLinx communication card. It is a 2-channel type of communication card. The 1784-KTXD 2-channel communication card supports the DH+ and DH-485 networks. This card can also be used as a remote I/O scanner device in some applications. The 1784-KTXD 2-channel communication card can tolerate 5 to 95% relative humidity levels without condensation in both operation and storage.
We sell industrial automation parts backed by our 2-year DO Supply Warranty.
Same-day domestic and expedited international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, and more, plus flexible payment plans.
Repair and exchange services for all existing automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
Brand | Allen-Bradley / Rockwell Automation |
---|---|
Series | PLC 5 |
Part Number | 1784-KTXD |
Product type | Communication card |
Channels | 2 |
Compatibility | 16-bit EISA / ISA card expansion slot |
Remote I/O scanner | Yes |
DH+ / DH-485 node | Yes |
Operating temperature | 0 to 60 degrees Celsius |
Storage temperature | -40 to 85 degrees Celsius |
Relative humidity | 5 to 95% |
UPC | 10612598008121 |
The Allen-Bradley 1784-KTXDĀ card is a communication card from NetLinx. The 1784-KTXDĀ card has two channels and it can act as a node for the DH+Ā or DH-485 networks. However the 1784-KTXDĀ card can act as node for DH-485 networks only on channel 1. The 1784-KTXD card can also act as a remote I/O scanner. The card is compatible with a 16-bit EISA/ISA card expansion slot. However, the card is not compatible with 8-bit slots.
The 1784-KTXDĀ card communicates with nodes on DH networks, including PLC-3 / PLC-2 nodesĀ on DH+ networks that also includeĀ the PLC-5 and SLC 5/04 processor nodesĀ and the SLC 5/03, SLC 5/02, and SLC 5/01 processors. The 1784-KTXDĀ card can also communicate with SLC processors on the DH-485 network. As the 1784-KTXDĀ card is a dual-channel card that hasĀ 2Ā base memory addresses that need to be configured before it can be installed. The interrupt setting of the card also needs to be set prior to installation. The operating shock rating for the 1784-KTXDĀ card is 30 GĀ for 11 seconds and the non-operational shock rating is 50 GĀ for 11 milliseconds. The operational and non-operational temperature ranges for the card are from 0 to 60 degrees Celsius and -40 to 85 degrees Celsius, respectively. The non-condensing relative humidity around the card should be between 5 and 95%.
Revision Part # | Also known as | |
---|---|---|
1784-KTXD Ser A | 1784-KTXD/A, Series A, Rev A | Request a quote |
1784-KTXD Ser B | 1784-KTXD/B, Series B, Rev B | Request a quote |
Don't see your particular revision? Contact us now. |
The Allen-Bradley NetLinx 1784-KTXD card is a communication card. TheĀ 1784-KTXD card is a two-channel card.