Rockwell Disclaimer: The product is used surplus. DO Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because DO Supply is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. DO Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. DO Supply also makes no representations as to your right to install any such firmware on the product. DO Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Rockwell Disclaimer: The product is used surplus. DO Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because DO Supply is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. DO Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. DO Supply also makes no representations as to your right to install any such firmware on the product. DO Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.


credit cards accepted
better business bureau

3150-MCM

Revisions: Ser A Ser B Ser C 
Description: The 3150-MCM is a Modbus communication module from Allen-Bradley’s encompasses partner company, Prosoft Technology. This module is a single slot module with Two (2) RS232 / RS422 / RS485 ports supporting Modbus Master / Slave protocol. This module supports the transfer of up to 4000 registers to the PLC /SLC data tables and binary, integer, ASCII, and floating-point data types.
In Stock Ships Today
Request a quote for 3150-MCM

Description: The 3150-MCM is a Modbus communication module from Allen-Bradley’s encompasses partner company, Prosoft Technology. This module is a single slot module with Two (2) RS232 / RS422 / RS485 ports supporting Modbus Master / Slave protocol. This module supports the transfer of up to 4000 registers to the PLC /SLC data tables and binary, integer, ASCII, and floating-point data types.

DO Supply is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply. Product comes with DO Supply's 1-year warranty

Rockwell Disclaimer: The product is used surplus. DO Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because DO Supply is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. DO Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. DO Supply also makes no representations as to your right to install any such firmware on the product. DO Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

disclaimer
credit cards
better business bureau
Revisions: Ser A Ser B Ser C 

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via UPS, DHL, and TNT
Repairs: We offer repair service for the 3150-MCM.
Exchange: Exchange credit for your defective unit available.
Conditions: We sell preowned surplus and refurbished parts.

To speak to a sales representative for pricing & lead time:


Rated 4.9 with 20 reviews

    Technical Specifications for 3150-MCM

ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.3150-MCM
Manufacturer: Prosoft Technology
Product TypeModbus Master/Slave Communication Module
Product Description: Modbus communication module
Part Number: 3150-MCM
Command List Entries100
Word Reads and Writes125
3150-MCMModbus
Registers4000 max.
Modbus operating ModesMaster / Slave
CommandsBroadcast
No. of portsTwo (2) RS232 / RS485 / RS422
Processor Data TransferAsynchronous
Compatible controllers PLC Platform
Write CommandsEvent Driven Bit and Register
Supported Modbus Function codes (Slave)1 Read Output Status; 2 Read Input Status; 3 Read Multiple Data Registers; 4 Read Input Registers; 5 Force Single Coil (Latch/Unlatch); 6 Preset (Write) Single Data Register; 15 Multiple Coil Latch/Unlatch and 16 Preset (Write) Multiple Data Register.
Optical Isolation500V
Supported Modbus Function codes (Master)1 Read Output Status; 2 Read Input Status; 3 Read Multiple Data Registers; 4 Read Input Registers; 5 Force Single Coil (Latch/Unlatch); 6 Preset (Write) Single Data Register; 15 Multiple Coil Latch/Unlatch and 16 Preset (Write) Multiple Data Register.
Backplane Current Load5V @ 0.15 A
Slot WidthSingle slot
Data Transfer size 4000 registers
Data TypesBinary, integer, ASCII, and floating point data
Backplane Current draw0.15 A at 5 V; 0.04 A at 24 V
Operating Temperature 0 to 60°C (32 to 140°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Relative Humidity 5% to 95% (non-condensing)
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.3150-MCM
Manufacturer: Prosoft Technology
Product TypeModbus Master/Slave Communication Module
Product Description: Modbus communication module
Part Number: 3150-MCM
Command List Entries100
Word Reads and Writes125
3150-MCMModbus
Registers4000 max.
Modbus operating ModesMaster / Slave
CommandsBroadcast
No. of portsTwo (2) RS232 / RS485 / RS422
Processor Data TransferAsynchronous
Compatible controllers PLC Platform
Write CommandsEvent Driven Bit and Register
Supported Modbus Function codes (Slave)1 Read Output Status; 2 Read Input Status; 3 Read Multiple Data Registers; 4 Read Input Registers; 5 Force Single Coil (Latch/Unlatch); 6 Preset (Write) Single Data Register; 15 Multiple Coil Latch/Unlatch and 16 Preset (Write) Multiple Data Register.
Optical Isolation500V
Supported Modbus Function codes (Master)1 Read Output Status; 2 Read Input Status; 3 Read Multiple Data Registers; 4 Read Input Registers; 5 Force Single Coil (Latch/Unlatch); 6 Preset (Write) Single Data Register; 15 Multiple Coil Latch/Unlatch and 16 Preset (Write) Multiple Data Register.
Backplane Current Load5V @ 0.15 A
Slot WidthSingle slot
Data Transfer size 4000 registers
Data TypesBinary, integer, ASCII, and floating point data
Backplane Current draw0.15 A at 5 V; 0.04 A at 24 V
Operating Temperature 0 to 60°C (32 to 140°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Relative Humidity 5% to 95% (non-condensing)
s

About 3150-MCM

The 3150-MCM is manufactured by Prosoft Technology, an Allen-Bradley encompass partner company. This module features compatibility with Allen-Bradley’s PLC platform. It occupies a single slot of the chassis only and supports Modbus Master and Slave configuration. It has Two (2) communication ports configurable for RS232 / RS422 and RS485 communication standards. These ports are individually configurable to operate as Master; Master / Slave or Slave. The 3150-MCM supports storage and transfer of up to 4000 registers to any compatible Modbus-enabled device and movement of binary, integer, ASCII, and floating-point data types. Additionally, user configuring the 3150-MCM can implement custom memory mapping through highly definable data tables. The 3150-MCM operational parameters are configured using the ladder logic programming language. Configurable slave address is 1 - 247; None, odd or even parity; 1 or 2 stop bits; 300 to 38400 stop bits; 0-65535 ms with 1 ms resolution RTS to TxD; 0-65535 ms with 1 ms resolution RTS Off and 0-65535 ms with 1 ms resolution timeout. When operating as Modbus slave, this module supports MODBUS function codes such as 1 Read Output Status; 2 Read Input Status; 3 Read Multiple Data Registers; 4 Read Input Registers; 5 Force Single Coil (Latch/Unlatch); 6 Preset (Write) Single Data Register; 8 Loopback Test (Test 0 only); 15 Multiple Coil Latch/Unlatch; and 16 Preset (Write) Multiple Data Register. As Modbus master, the 3150-MCM supports 1 Read Output Status; 2 Read Input Status; 3 Read Multiple Data Registers; 4 Read Input Registers; 5 Force Single Coil (Latch/Unlatch); 6 Preset (Write) Single Data Register; 15 Multiple Coil Latch/Unlatch and 16 Preset (Write) Multiple Data Register.

The Allen-Bradley 3150-MCM is a module from ProSoft Technology which enables 1746 I/O compatible processors from Allen-Bradley/Rockwell Automation to interface with other devices running the Modbus protocol. It features 2 serial ports which can function as a Modbus master or as a Modbus slave unit. The 3150-MCM module can be installed in either a local or extended rack, but not in a remote rack. The backplane current load of the 3150-MCM module is 0.15 Amps at 5 Volts DC and 0.04 Amps at 24 Volts DC. The size of the phase conductors used with the module must be a minimum of 1.3 millimeters squared and the size of the earth conductors must be a minimum of 4 millimeters squared. Two DB-9 male physical interfaces are available on the module.

Both serial interfaces on the 3150-MCM module are compatible with the RS-422, RS-485, and RS-232 protocols. The module also supports satellite and packet radio with programmable inter-character timeout on each port. Additional module features include the ability to transfer 4000 registers to date tables on an SLC or PLC, the ability to move ASCII, binary, and floating-point data, and memory mapping through data table configuration. The 3150-MCM module is not hot-swappable and therefore the rack power must be disabled before this module is inserted or removed. Failure to do so may cause damage to the module, processor, or other connected devices. The module should be installed in an IP 54 enclosure. The working temperature range for the 3150-MCM module is from 32 to 140 degrees Fahrenheit. The temperature range for unused modules which are kept in storage is from -40 to 185 degrees Fahrenheit.

FAQ for 3150-MCM

1. What is the communication protocol supported by the 3150-MCM?


The 3150-MCM supports Modbus communication protocol.

2. What are the operable Modbus modes by the 3150-MCM?


The 3150-MCM supports Modbus master and Slave operation.

3. How many Modbus ports does the 3150-MCM have?


The 3150-MCM has Two 92) MODBUS communication ports.

Technical Description of 3150-MCM

The ProSoft 3150-MCM Modbus Master/Slave Communication Module has 100 Command List Entries and 125 Word Reads and Writes. It also has 4000 max. Registers and Broadcast Commands.

Repair Services for 3150-MCM

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 3150-MCM. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions for 3150-MCM

Please refer to the manual for more information about the 3150-MCM such as the wiring diagrams, data sheets and migration or obsolescence details.

Revision Part # Also Known as Availability
3150-MCM Ser A
3150-MCM/A, Series A, Rev A Request Quote
3150-MCM Ser B
3150-MCM/B, Series B, Rev B Request Quote
3150-MCM Ser C
3150-MCM/C, Series C, Rev C Request Quote
Common misspellings:
  • 3l50-MCM
  • 315o-MCM
  • 3150MCM

Reviews for 3150-MCM

Product Review

"The 3150-MCM is a Modbus Master and Slave communication module that is compatible with Allen-Bradley’s PLC controller platform. This module comes with Two (2) Modbus-enabled ports. With the use of the 3150-MCM, the PLC series may communicate with legacy or even modern Modbus-enabled devices. " -DO Supply Tech

Dimensions For 3150-MCM

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For 3150-MCM

Resolutions For 3150-MCM

About

Technical Specifications for 3150-MCM

ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.3150-MCM
Manufacturer: Prosoft Technology
Product TypeModbus Master/Slave Communication Module
Product Description: Modbus communication module
Part Number: 3150-MCM
Command List Entries100
Word Reads and Writes125
3150-MCMModbus
Registers4000 max.
Modbus operating ModesMaster / Slave
CommandsBroadcast
No. of portsTwo (2) RS232 / RS485 / RS422
Processor Data TransferAsynchronous
Compatible controllers PLC Platform
Write CommandsEvent Driven Bit and Register
Supported Modbus Function codes (Slave)1 Read Output Status; 2 Read Input Status; 3 Read Multiple Data Registers; 4 Read Input Registers; 5 Force Single Coil (Latch/Unlatch); 6 Preset (Write) Single Data Register; 15 Multiple Coil Latch/Unlatch and 16 Preset (Write) Multiple Data Register.
Optical Isolation500V
Supported Modbus Function codes (Master)1 Read Output Status; 2 Read Input Status; 3 Read Multiple Data Registers; 4 Read Input Registers; 5 Force Single Coil (Latch/Unlatch); 6 Preset (Write) Single Data Register; 15 Multiple Coil Latch/Unlatch and 16 Preset (Write) Multiple Data Register.
Backplane Current Load5V @ 0.15 A
Slot WidthSingle slot
Data Transfer size 4000 registers
Data TypesBinary, integer, ASCII, and floating point data
Backplane Current draw0.15 A at 5 V; 0.04 A at 24 V
Operating Temperature 0 to 60°C (32 to 140°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Relative Humidity 5% to 95% (non-condensing)
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.3150-MCM
Manufacturer: Prosoft Technology
Product TypeModbus Master/Slave Communication Module
Product Description: Modbus communication module
Part Number: 3150-MCM
Command List Entries100
Word Reads and Writes125
3150-MCMModbus
Registers4000 max.
Modbus operating ModesMaster / Slave
CommandsBroadcast
No. of portsTwo (2) RS232 / RS485 / RS422
Processor Data TransferAsynchronous
Compatible controllers PLC Platform
Write CommandsEvent Driven Bit and Register
Supported Modbus Function codes (Slave)1 Read Output Status; 2 Read Input Status; 3 Read Multiple Data Registers; 4 Read Input Registers; 5 Force Single Coil (Latch/Unlatch); 6 Preset (Write) Single Data Register; 15 Multiple Coil Latch/Unlatch and 16 Preset (Write) Multiple Data Register.
Optical Isolation500V
Supported Modbus Function codes (Master)1 Read Output Status; 2 Read Input Status; 3 Read Multiple Data Registers; 4 Read Input Registers; 5 Force Single Coil (Latch/Unlatch); 6 Preset (Write) Single Data Register; 15 Multiple Coil Latch/Unlatch and 16 Preset (Write) Multiple Data Register.
Backplane Current Load5V @ 0.15 A
Slot WidthSingle slot
Data Transfer size 4000 registers
Data TypesBinary, integer, ASCII, and floating point data
Backplane Current draw0.15 A at 5 V; 0.04 A at 24 V
Operating Temperature 0 to 60°C (32 to 140°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Relative Humidity 5% to 95% (non-condensing)

About 3150-MCM

The 3150-MCM is manufactured by Prosoft Technology, an Allen-Bradley encompass partner company. This module features compatibility with Allen-Bradley’s PLC platform. It occupies a single slot of the chassis only and supports Modbus Master and Slave configuration. It has Two (2) communication ports configurable for RS232 / RS422 and RS485 communication standards. These ports are individually configurable to operate as Master; Master / Slave or Slave. The 3150-MCM supports storage and transfer of up to 4000 registers to any compatible Modbus-enabled device and movement of binary, integer, ASCII, and floating-point data types. Additionally, user configuring the 3150-MCM can implement custom memory mapping through highly definable data tables. The 3150-MCM operational parameters are configured using the ladder logic programming language. Configurable slave address is 1 - 247; None, odd or even parity; 1 or 2 stop bits; 300 to 38400 stop bits; 0-65535 ms with 1 ms resolution RTS to TxD; 0-65535 ms with 1 ms resolution RTS Off and 0-65535 ms with 1 ms resolution timeout. When operating as Modbus slave, this module supports MODBUS function codes such as 1 Read Output Status; 2 Read Input Status; 3 Read Multiple Data Registers; 4 Read Input Registers; 5 Force Single Coil (Latch/Unlatch); 6 Preset (Write) Single Data Register; 8 Loopback Test (Test 0 only); 15 Multiple Coil Latch/Unlatch; and 16 Preset (Write) Multiple Data Register. As Modbus master, the 3150-MCM supports 1 Read Output Status; 2 Read Input Status; 3 Read Multiple Data Registers; 4 Read Input Registers; 5 Force Single Coil (Latch/Unlatch); 6 Preset (Write) Single Data Register; 15 Multiple Coil Latch/Unlatch and 16 Preset (Write) Multiple Data Register.

The Allen-Bradley 3150-MCM is a module from ProSoft Technology which enables 1746 I/O compatible processors from Allen-Bradley/Rockwell Automation to interface with other devices running the Modbus protocol. It features 2 serial ports which can function as a Modbus master or as a Modbus slave unit. The 3150-MCM module can be installed in either a local or extended rack, but not in a remote rack. The backplane current load of the 3150-MCM module is 0.15 Amps at 5 Volts DC and 0.04 Amps at 24 Volts DC. The size of the phase conductors used with the module must be a minimum of 1.3 millimeters squared and the size of the earth conductors must be a minimum of 4 millimeters squared. Two DB-9 male physical interfaces are available on the module.

Both serial interfaces on the 3150-MCM module are compatible with the RS-422, RS-485, and RS-232 protocols. The module also supports satellite and packet radio with programmable inter-character timeout on each port. Additional module features include the ability to transfer 4000 registers to date tables on an SLC or PLC, the ability to move ASCII, binary, and floating-point data, and memory mapping through data table configuration. The 3150-MCM module is not hot-swappable and therefore the rack power must be disabled before this module is inserted or removed. Failure to do so may cause damage to the module, processor, or other connected devices. The module should be installed in an IP 54 enclosure. The working temperature range for the 3150-MCM module is from 32 to 140 degrees Fahrenheit. The temperature range for unused modules which are kept in storage is from -40 to 185 degrees Fahrenheit.

FAQ for 3150-MCM

1. What is the communication protocol supported by the 3150-MCM?


The 3150-MCM supports Modbus communication protocol.

2. What are the operable Modbus modes by the 3150-MCM?


The 3150-MCM supports Modbus master and Slave operation.

3. How many Modbus ports does the 3150-MCM have?


The 3150-MCM has Two 92) MODBUS communication ports.

Technical Description of 3150-MCM

The ProSoft 3150-MCM Modbus Master/Slave Communication Module has 100 Command List Entries and 125 Word Reads and Writes. It also has 4000 max. Registers and Broadcast Commands.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 3150-MCM. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 3150-MCM. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions

Please refer to the manual for more information about the 3150-MCM such as the wiring diagrams, data sheets and migration or obsolescence details.

Revision Part # Also Known as Availability
3150-MCM Ser A
3150-MCM/A, Series A, Rev A Request Quote
3150-MCM Ser B
3150-MCM/B, Series B, Rev B Request Quote
3150-MCM Ser C
3150-MCM/C, Series C, Rev C Request Quote

Common misspellings:
  • 3l50-MCM
  • 315o-MCM
  • 3150MCM
PDF
Reviews

Reviews for 3150-MCM

Product Review

"The 3150-MCM is a Modbus Master and Slave communication module that is compatible with Allen-Bradley’s PLC controller platform. This module comes with Two (2) Modbus-enabled ports. With the use of the 3150-MCM, the PLC series may communicate with legacy or even modern Modbus-enabled devices. " -DO Supply Tech