MVI71-MNET

|

The MVI71-MNET is a Modbus TCP / IP Interface module from Allen-Bradley’s encompass partner company, Prosoft Technology. This module is a single slot module with ethernet application port supporting 10/100 MB transmission speed and a configuration serial port that supports RS232 electrical standard. This module supports explicit messaging through Block Transfer Read (BTR) and Block Transfer Write (BTW) with a variety of components including Modicon devices.

Call for an immediate quote
2 Year DO Supply Warranty
Available
Ships from Raleigh, NC
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with DO Supply's 2-year warranty.
Learn more
  • We sell industrial automation parts backed by our 2-year DO Supply Warranty.

  • Same-day domestic and expedited international shipping with UPS, FedEx, DHL, and more.

  • AMEX, Visa, MasterCard, Discover, wire transfer, and more, plus flexible payment plans.

  • Repair and exchange services for all existing automation products.

  • Reseller Options

    Drop shipping, blind shipping, and account shipping with no extra fees.

Technical specifications for MVI71-MNET

ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.MVI71-MNET
Manufacturer Prosoft Technology
Manufacturer: Prosoft Technology
Product TypeModbus TCP/IP module
Catalog No.MVI71-MNET
Product Description: Modbus TCP I/P Interface module
Compatible platform PLC Series
Part Number: MVI71-MNET
Rockwell Automation Compatible SeriesProgrammable Logic Controller
Supported Protocol: Modbus
Supported Protocol Modbus TCP/IP
Slot1
Enron version Supported
No of server connection on Port 502Five (5)
Data TransferLadder Logic
Function codes:01, 02, 03, 04, 05, 06, 08, 15, 16,17,22, 23
No of server connection on Port 2000Five (5)
Registers5000
Communication ports: One (1) RJ45 Ethernet port One (1) RS232 configuration port (CFG)
Supported function codes1, 2, 3, 4, 5, 6, 8, 15, 16, 17, 22 and 23
Servers/Devices per Client Connection100 max.
Supported Modbus modes:Master / Slave
No, of commands100 commands per port
Interface10/100 MB Ethernet-compatible
Module width: Single slot
Communication Port: Application port; Configuration port; Emulation port
Backplane Current Load800 mA @ 5V DC; 3 mA @ 24 VDC
Compatible backplane: 1771 Backplane
Ethernet Data Transfer speed: 10 / 100 mbps
Operating Shock30 G
Media: Copper
Non-operating shock 50 G
Compatible devices: PLC5/E rev C/N, D/E, E/D SLC5/05 series A, OS503 frn4 1785-ENET Series A, rev D Interchange V6.2 MicroLogix 1100/1400/ANY via 1761-NET-ENI CompactLogix 1768-L43/L45 via 1768-ENBT CompactLogix 1769-L32E/L35E/ANY CompactLogix L23E RSLinx Gateway V1.7+ ControlLogix 1756-ENET/ENBT/EN2T/EN2TR
Operating Temperature:0 to 60degrees C (32 to 140degrees F)
Form Factor Single Slot 1771 chassis compatible
Relative humidity5-95%
Mounting LocationRemote or Local rack
LED indicators Module Status; Backplane transfer status; Application Status; Serial Port Activity; Error LED status.
Modbus network analyzer Included
Rockwell Disclaimer: The product is used surplus. DO Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because DO Supply is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. DO Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. DO Supply also makes no representations as to your right to install any such firmware on the product. DO Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

The MVI71-MNET is manufactured by Prosoft Technology that is compatible for use with Allen-Bradley’s PLC series. This module is specifically a Modbus TCP I/P interface module that supports Block Transfer read (BTR) and Block Transfer Write (BTW) for implementing explicit Modbus messaging. This module comes with an Ethernet application port that supports 10/100 Mbps and a configuration port that is compatible with the RS232 electrical standard used for module configuration. The MVI71-MNET is compatible with Modicon controllers, PLC5/E rev C/N, D/E, E/D, SLC5/05 series A, OS503 frn4, 1785-ENET Series A, rev D, Interchange V6.2, MicroLogix 1100/1400/ANY via 1761-NET-ENI, CompactLogix 1768-L43/L45 via 1768-ENBT, CompactLogix 1769-L32E/L35E/ANY, CompactLogix L23E, RSLinx Gateway V1.7+, and ControlLogix 1756-ENET/ENBT/EN2T/EN2TR. This module includes a powerful Modbus network analyzer and supports special Modbus functions such as command control, event commands, status, etc. It supports up to Five (5) independent server connections on port 502 and the same feature on port 2000. The user data memory of this module stores error codes, network error counters, and port status, which can be mapped and analyzed to determine the health and performance of the network. The MVI71-MNET can be installed in a remote or local rack. It is a single slot module that is installed at any available slot of the 1771chassis. It has a minimum response delay of 0 - 65535 msec; a response timeout of 1 - 65535 msec and a configurable retry count of 0-20. It allows command control from ladder logic and permits pass-through configuration. This module has a tertiary port that is capable of emulating channel 0 of the PLC.

The MVI71-MNET module is a ProSoft Technology manufactured Modbus TCP/IP network interface module. It is classified under the Allen-Bradley/Rockwell Automation programmable Logic controller series. The unit is used for allowing the Allen-Bradley/Rockwell Automation processors to have easy interfacing with the Modbus compatible devices. The MVI71-MNET module is compatible with the Modicon programmable automation controllers and various other devices. The unit features a 5000-word register space and it exchanges data between the processor and the Modbus TCP/IP network. It comes with the single-slot 1771 backplane. The MVI71-MNET module uses the ladder logic data transfer protocol with support for up to 5000 registers. The unit comes with a maximum of 100 servers or devices per client connections, while the interface is a 10/100 MB Ethernet compatible application port. The MVI71-MNET module features a backplane current load of 800 mA at 5 Volts DC. The MVI71-MNET module includes the master and slave capabilities with Modbus data types overlapping in the module memory database. The MVI71-MNET module supports the Enron version of the Modbus Protocol for ensuring floating-point data transactions. It also comes with a powerful Modbus network analyzer. The MVI71-MNET module supports special functionalities, including the command control, event commands, and status monitoring capabilities. These functionalities are supported by the message transfer and by using the included MSG instruction. The MVI71-MNET module features a configurable parameter for the client, including a minimum response delay of 0 to 65535 milliseconds. For service port 502, the unit supports 10 independent server connections. The entire data mapping process begins with the Modbus register 40001. The MVI71-MNET module records error codes, network error counters, and the port status data in the included user data memory.

Revision Part #Also known as
MVI71-MNET Ser AMVI71-MNET/A, Series A, Rev A
Request a quote
Don't see your particular revision? Contact us now.

Testimonials

4.99 /5.0
Recommended
4.99 average / 907 reviews