Product image is representative; revision or series may vary. Contact us to request a specific version.
The Allen-Bradley 2711-T10C10 is a PanelView 1000 Standard Operator Terminal. This operator terminal operates when supplied by an external supply voltage range of 85-264 Volts AC, 47-63 Hertz. It has a 10-inch colored display screen with a touchscreen input interface. It has an embedded DeviceNet communication port and RS-232 printer interface.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | PanelView 1000 Standard Operator Terminals |
| Product Line | Panelview 1000 |
| Part Number | 2711-T10C10 |
| UPC | 662072718636 |
| Weight | 6.13 lbs (2.78 kg) |
| Product Family | PanelView Standard Operator Terminals |
| Operator Input | Touch |
| Display Type | Color Active matrix |
| Display Area | 211 x 158 mm (8.3 x 6.2 in.) |
| Resolution | 640 x 480 |
| Backlight | 50,000 hr LED backlight life half-life |
| Touch Interface | 1 million presses |
| Application memory | 310KB application runtime; 1008 KB nonvolatile memory |
| Communication ports | DeviceNet; RS232 (printer) |
| Input Voltage range | 85…264V AC |
| Input Frequency | 47…63 Hz |
| Enclosure | NEMA Type 12/13, 4X (Indoor use only), IP54, IP65 |
| Status Indicators | COMM: Green Fault: Red |
| Display Size | 10.1 in. |
| Display Color | Multi-Color |
| Input Type | Touchscreen |
| Communication | Printer (RS-232) Port and DeviceNet |
| Input Power | 85-264 Volts Alternating Current |
| Memory | 256 Kilobytes |
| Enclosure Type | NEMA Type 12/13 or 4X |
| Product Lifecycle Status* | Discontinued/Obsolete |
* The Allen Bradley 2711-T10C10 has been discontinued by the manufacturer, however we specialize in obsolete parts and can likely still supply surplus and/or refurbished replacement 2711-T10C10 units instead of migration.
The Allen-Bradley 2711-T10C10 terminal is a touchscreen human-machine interface terminal in the PanelView standard 1000 human-machine interface terminal series. This interface comes with a 10-inch color display that helps the operators have a better visualization of application processes due to its resolution of 640 by 480 pixels. The screen is a color active-matrix type of screen. The Allen-Bradley 2711-T10C10 human-machine interface terminal can operate without any inconvenience in environments that have a relative humidity range of 5 to 95%, without condensation, that have a maximum temperature rating of 50 degrees Celsius, and that have a maximum altitude of 2000 meters. It has been designed to operate in indoor environments only because the screen must be protected especially from ultraviolet rays that come from direct sunlight. This interface needs to be installed while following each step in the manual and after removing power from all the connected equipment. The Allen-Bradley 2711-T10C10 human-machine interface terminal has a display area of 211 by 158 millimeters and an overall width of 370 millimeters, a height of 282 millimeters, and a length of 112 millimeters. It also has a weight of 7 pounds. The communication mechanism provided by this interface terminal is a DeviceNet port with its own printer port. It also has a general memory of 1008 Kilobytes and a flash memory of 310 Kilobytes.
The Allen-Bradley 2711-T10C10 is a Human Machine Interface (HMI) device or sometimes referred to as a Human Machine Interface (MMI). This device is part of Allen-Bradley’s PanelView Standard 1000 operator terminal that features a 10-inch, color active matrix TFT screen, a DeviceNet communication interface, and touchscreen operator input.
The 2711-T10C10 is typically a flush mounted device, installed to an enclosure that offers a protection rating equivalent to NEMA Type 12, 13, 4X (indoor use only), IEC IP54, and IP65 standards. This enclosure must be provided with a panel cut-out that meets the required opening to properly mount the HMI device. Additionally, the enclosure must have a flat and smooth surface with vibration and shock limited up to 29 up to 2000 Hertz and 15 g, respectively.
The 2711-T10C10 also supports direct communication to an alarm printer via the embedded RS-232 printer port. This printer port may be configured to print alarm and events records at a specific and defined interval for the purpose of archiving and reporting. The RS-232 printer port has selectable baud rate configurations of 1200, 2400, 9600, and 19,200 Kbps.
This operator terminal also comes with a 1008 KB of non-volatile memory and 310 KB of Random Access Memory (RAM). Optional ATA memory cards may be installed to the 2711-T10C10 to compliment the embedded non-volatile memory.
To operate this operator terminal, an external supply voltage range of 85-264 Volts AC must be wired to the power inputs of this device along a frequency range of 47-63 Hertz. It has a power consumption of 55 Volt-amperes.
| Revision Part # | Also known as | |
|---|---|---|
| 2711-T10C10 Ser A | 2711-T10C10/A, Series A, Rev A | |
| 2711-T10C10 Ser B | 2711-T10C10/B, Series B, Rev B | |
| 2711-T10C10 Ser C | 2711-T10C10/C, Series C, Rev C | |
| 2711-T10C10 Ser D | 2711-T10C10/D, Series D, Rev D | |
| 2711-T10C10 Ser E | 2711-T10C10/E, Series E, Rev E | |
| 2711-T10C10 Ser F | 2711-T10C10/F, Series F, Rev F | |
| 2711-T10C10X | 2711-T10C10/X, Series X, Rev X | |
| Don't see your particular revision? Contact us now. | ||
Yes, the 2711-T10C10 includes a free 2-year DO Supply warranty. You can upgrade to a 3-year warranty at checkout for even more protection.
Yes, the backlight of a PanelView 1000 2711-T10C10 terminal is replaceable.
Yes, the battery of a PanelView1000 2711-T10C10 is field replaceable.
Submit a quote request, send us an email, or call +1 (919) 205-4392 for our best price.
Yes. ATA memory cards are supported by the 2711-T10C10.
No. Only Horizontal installation is supported by this HMI hardware.
Yes. It has a field replaceable backlight with half-life rating of 50,000 hours.
DeviceNet Communication and RS-232 Printer Port
| Size | 10 inch |
|---|---|
| Input Type | Touch |
| Panel Cutout Height | 257 mm (10.11 in) |
| Panel Cutout Width | 338 mm (13.29 in) |
| Terminal Height | 282 mm (11.11 in) |
| Terminal Width | 370 mm (14.58 in) |
| Terminal Overall Depth | 112 mm (4.4 in) |
| Terminal Mounted Depth | 90 mm (3.54 in) |
| Size | 10 inch |
|---|---|
| Input Type | Touch |
| Display Type | Color active matrix TFT |
| Display Size (Diagonal) | 10 in. |
| Viewing Area | 211 x 158 mm (8.3 x 6.2 in.) |
| Display Resolution | 640 x 480 |