2711-T10C8

Rated 4.8 with 23 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

2711-T10C8

Description: The Allen-Bradley 2711-T10C8 is a PanelView 1000 Standard Operator Terminal. This operator terminal is powered by an external 85-264VAC supply voltage and has a 10.1-inch colored display with embedded Data Highway Plus (DH+) and RS232 port for printer interface. It has an analog resistive touchscreen operator interface.
In Stock Ships Today
Request a quote for 2711-T10C8

Description: The Allen-Bradley 2711-T10C8 is a PanelView 1000 Standard Operator Terminal. This operator terminal is powered by an external 85-264VAC supply voltage and has a 10.1-inch colored display with embedded Data Highway Plus (DH+) and RS232 port for printer interface. It has an analog resistive touchscreen operator interface.

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 2711-T10C8 in 3-5 days.
Exchange: Exchange credit for your defective unit available.

To speak to a sales representative for pricing & lead time:


Rated 4.8 with 23 reviews

    Technical Specifications for 2711-T10C8

Input TypeTouch
SoftwarePanelBuilder32
BrandAllen-Bradley
Manufacturer:Rockwell Automation
Product Family:PanelView Standard Terminals
Product Type:PanelView 1000 Standard Operator Terminals
Display Type:Active Matrix Thin-Film Resistor (TFT) with Cold Cathode Fluorescent (CCF) Backlight
Display Area:211 x 158 mm (8.3 x 6.2 in.)
Resolution:640 x 480 pixels
Backlight:100,000 hr LED backlight life
Touchscreen:384 (24 columns x 16 rows)
Touch Cell size:26 x 30 pixels
Application memory:1008K bytes (application screens)
Communication ports:Data Highway Plus (DH+); RS232 (printer)
Input Voltage range:85…264V AC, 47…63 Hz
Operating Temperature:0…55 ° C (32…131 ° F)
Heat Dissipation:39 W (132 BTU/HR)
Part Number/Catalog No.2711-T10C8
Product LinePanelview 1000
Display Size10.1 in.
Display ColorMulti-Color
CommunicationDH Plus (DH+) and Printer (RS-232) Port
Power Source Rating100-240 VAC
Memory256 Kilobytes
Enclosure TypeNEMA Type 12/13 or 4X
UPC10662072718619
Product Lifecycle Status*Discontinued/Obsolete

*The Allen Bradley 2711-T10C8 has been discontinued by the manufacturer, however we specialize in obsolete parts and can likely still supply surplus and/or refurbished replacement 2711-T10C8 units instead of migration.

Input TypeTouch
SoftwarePanelBuilder32
BrandAllen-Bradley
Manufacturer:Rockwell Automation
Product Family:PanelView Standard Terminals
Product Type:PanelView 1000 Standard Operator Terminals
Display Type:Active Matrix Thin-Film Resistor (TFT) with Cold Cathode Fluorescent (CCF) Backlight
Display Area:211 x 158 mm (8.3 x 6.2 in.)
Resolution:640 x 480 pixels
Backlight:100,000 hr LED backlight life
Touchscreen:384 (24 columns x 16 rows)
Touch Cell size:26 x 30 pixels
Application memory:1008K bytes (application screens)
Communication ports:Data Highway Plus (DH+); RS232 (printer)
Input Voltage range:85…264V AC, 47…63 Hz
Operating Temperature:0…55 ° C (32…131 ° F)
Heat Dissipation:39 W (132 BTU/HR)
Part Number/Catalog No.2711-T10C8
Product LinePanelview 1000
Display Size10.1 in.
Display ColorMulti-Color
CommunicationDH Plus (DH+) and Printer (RS-232) Port
Power Source Rating100-240 VAC
Memory256 Kilobytes
Enclosure TypeNEMA Type 12/13 or 4X
UPC10662072718619
Product Lifecycle Status*Discontinued/Obsolete

*The Allen Bradley 2711-T10C8 has been discontinued by the manufacturer, however we specialize in obsolete parts and can likely still supply surplus and/or refurbished replacement 2711-T10C8 units instead of migration.

s

About 2711-T10C8

The Allen-Bradley graphic operator terminal with catalog number 2711-T10C8 is part of the 2711 PanelView Standard operator terminals. It is specifically part of the PanelView Plus 1000 operator terminals which comes with standard capabilities such as a 10.1-inch colored display screen with resolution of 640 x 480 pixels, touch input interface and integral 1008 Kbytes internal flash memory.

The 2711-T10C8 has specific feature provided by the built-in Data Highway Plus (DH+) communication port and RS232 Printer interface. The DH+ port is used for exchanging data with partner controllers such as PLC5, SLC500, and other Allen-Bradley Programable Logic Controllers (PLC), even with 3rd party devices with support for DH+ protocol as well. DH+ uses a 3-wire cable, which may be implemented in long distances and support communication with one or more controllers. The secondary port which is the RS232 is used for communicating with alarm printers, enabling printing and documenting of alarms and events for historization and reports.

The 2711-T10C8 is a flush mounted to an enclosure and supports horizontal orientation only. It requires mounting clearance of 51 mm or 2 inches on all sides to ensure adequate air flow as well as working space for installation of additional components intended for the operator terminal.

The 2711-T10C8 is mounted to an enclosure rated NEMA Type 12/13, 4X (Indoor use only) IP54, IP65. The required operating temperature is 0…55 ° C (32…131 ° F) with shock and vibration rating of 15 g and 2 g up to 2,000 Hz respectively. Install appropriate cooling and heating devices to maintain the required temperature as well shoch and vibration protection to achieve maximum operating life of the operator terminal.

In addition to communicating with machine controllers, the 2711-T10C8 PanelView 1000 is an excellent input module, allowing the user to input information and commands through its sharp, 10-inch touchscreen. The display is multicolored as is approximately 8.3 inches by 6.2 inches. This display doubles as the touch input touchscreen, with a 1-million press approximate actuation. Its field-replaceable backlight has a 50,000 hour half-life at a consistent temperature of 77 degrees Fahrenheit, and the module’s built-in time-stamping clock runs on batteries that can also be replaced in the field.

The 2711-T10C8 can hold up to 1008 kilobytes of nonvolatile memory, along with 310 kilobytes of application runtime memory. In addition to both of those storage options, the 2711-T10C8 PanelView can support ATA flash memory cards, for additional external memory storage. The 2711-T10C8 uses PanelBuilder32 software only, a versatile, common software that can also be installed on a personal computer.

The 2711-T10C8 is powered by an external voltage supply of 85 and 264 Volts of AC power to operate on a frequency between 47 and 63 Hertz. In general, this module’s applications will consume no more than 55 VA. The 2711-T10C8 weighs between 7 and 8 pounds or 3.2 to 3.6 kilograms. Its size is around 11.11 x 14.58 x 4.40 inches, and it should be kept lower than 6561 feet when mounted. This PanelView 1000 series of modules operates ideally when the surrounding temperature stays lower than 131 degrees Fahrenheit, but higher than 32 (or freezing point). Similarly, it is best stored in a temperature zone between -13 and 158 degrees Fahrenheit. Keep in mind that the 2711-T10C8 cannot withstand more than 2 g of vibration at up to 2000 Hertz and that it is limited to 15 g of shock while operating, and 30 g of shock while off.

FAQ for 2711-T10C8

What type of input does the 2711-T10C8 have?


The 2711-T10C8 has a touchscreen type input.

What kind of storage does the 2711-T10C8 contain?


The 2711-T10C8 has 310 kilobytes of application runtime memory along with 1008 kilobytes of nonvolatile memory and an ATA flash memory port.

What type of enclosure should be used for the 2711-T10C8?


The 2711-T10C8 has enclosure ratings of NEMA Type 12, 13, 4X (indoor use only), IEC IP54, IP65.

How much input power does the 2711-T10C8 require?


The 2711-T10C8 requires between 85 and 264 Volts of AC.

Can I order a warranty with the 2711-T10C8?


The 2711-T10C8 comes with a one-year DO Supply warranty.

Does the 2711-T10C8 have an anti-glare overlay?


Yes, 2711-T10C8 has an anti-glare overlay. Its part number is 2711-NV6T.

Does the 2711-T10C8 have a backlight lamp replacement?


Yes, the 2711-T10C8 has a backlight replacement with the number 2711-NL4; before ordering, check the series of the 2711-T10C8 terminal as Series B, C, D, and F require different backlight replacements.

When installing the 2711-T10C8, what are the recommended panel cut-out dimensions?


The recommended cut-out dimensions when installing the 2711-T10C8 are 10.11 x 13.29 inches (H x W).

What is the embedded communication interface of the 2711-T10C8?


The 2711-T10C8 has Data Highway Plus (DH+) and RS232 Printer interface.

What are the required installation clearance of the 2711-T10C8?


The 2711-T10C8 follows the standard requirement of PanelView Standard operator terminals of 51 mm or 2 inches clearance on all sides of the terminal.

What are the recommended enclosures for use with the 2711-T10C8?


The 2711-T10C8 recommended enclosure is NEMA Type 12/13, 4X (Indoor use only) IP54, IP65.

Technical Description of 2711-T10C8

This Panelview 1000 Display has a DH+ Communication port and a RS-232 Printer Port.  The HMI has a 10.1 inch toushcreen and a memory card slot on the back of the unit. 

Repair Services for 2711-T10C8

Type Lead Time Price Action
Repair Service 2-4 weeks $1933.08cartAdd to Cart

Our highly skilled technicians can repair your 2711-T10C8. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions for 2711-T10C8

Please refer to the manual for more information about the 2711-T10C8 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
2711-T10C8/A, Series A, Rev A Request Quote
2711-T10C8/B, Series B, Rev B Request Quote
2711-T10C8/C, Series C, Rev C Request Quote
2711-T10C8/D, Series D, Rev D Request Quote
2711-T10C8/E, Series E, Rev E Request Quote
2711-T10C8/F, Series F, Rev F Request Quote
2711-T10C8X
2711-T10C8/X, Series X, Rev X Request Quote
Firmware Revisions

The 2711-T10C8 has several firmware revisions: 2711-T10C8-FRN 3.01, 2711-T10C8-FRN 3.13, 2711-T10C8-FRN 3.14, 2711-T10C8-FRN 3.30, 2711-T10C8-FRN 3.40, 2711-T10C8-FRN 4.00, 2711-T10C8-FRN 4.10, 2711-T10C8-FRN 4.20, 2711-T10C8-FRN 4.41, 2711-T10C8-FRN 4.43, 2711-T10C8-FRN 4.46, and 2711-T10C8-FRN 4.48

Common misspellings:
  • 27l1-T10C8
  • 271l-T10C8
  • 2711-Tl0C8
  • 2711-T1oC8
  • 2711-T10Cb
  • 2711T10C8

Reviews for 2711-T10C8

Internal Review

"The 2711-T10C8 is 10.1-inch is a PanelView 1000 standard operator terminal with colored screen. The main advantage when using this operator terminal compared to the PanelView 600 and PanelView 400 terminals is that the entire PanelView 1000 including the 2711-T10C8 has a larger screen size. With the 10.1-inch display screen, user can create a more detailed process mimic by embedding more symbols and more windows pop-ups can be displayed without covering the entire screen. This enhances the ease of use and interaction with the 2711-T10C8. " -DO Supply Tech

Dimensions For 2711-T10C8

Size 10 inch
Input Type Touch
Panel Cutout Height 257 mm (10.11 in)
Panel Cutout Width 338 mm (13.29 in)
Terminal Height 282 mm (11.11 in)
Terminal Width 370 mm (14.58 in)
Terminal Overall Depth 112 mm (4.4 in)
Terminal Mounted Depth 90 mm (3.54 in)

Dimensions For 2711-T10C8

Resolutions For 2711-T10C8

Size 10 inch
Input Type Touch
Display Type Color active matrix TFT
Display Size (Diagonal) 10 in.
Viewing Area 211 x 158 mm (8.3 x 6.2 in.)
Display Resolution 640 x 480
About

Technical Specifications for 2711-T10C8

Input TypeTouch
SoftwarePanelBuilder32
BrandAllen-Bradley
Manufacturer:Rockwell Automation
Product Family:PanelView Standard Terminals
Product Type:PanelView 1000 Standard Operator Terminals
Display Type:Active Matrix Thin-Film Resistor (TFT) with Cold Cathode Fluorescent (CCF) Backlight
Display Area:211 x 158 mm (8.3 x 6.2 in.)
Resolution:640 x 480 pixels
Backlight:100,000 hr LED backlight life
Touchscreen:384 (24 columns x 16 rows)
Touch Cell size:26 x 30 pixels
Application memory:1008K bytes (application screens)
Communication ports:Data Highway Plus (DH+); RS232 (printer)
Input Voltage range:85…264V AC, 47…63 Hz
Operating Temperature:0…55 ° C (32…131 ° F)
Heat Dissipation:39 W (132 BTU/HR)
Part Number/Catalog No.2711-T10C8
Product LinePanelview 1000
Display Size10.1 in.
Display ColorMulti-Color
CommunicationDH Plus (DH+) and Printer (RS-232) Port
Power Source Rating100-240 VAC
Memory256 Kilobytes
Enclosure TypeNEMA Type 12/13 or 4X
UPC10662072718619
Product Lifecycle Status*Discontinued/Obsolete
Input TypeTouch
SoftwarePanelBuilder32
BrandAllen-Bradley
Manufacturer:Rockwell Automation
Product Family:PanelView Standard Terminals
Product Type:PanelView 1000 Standard Operator Terminals
Display Type:Active Matrix Thin-Film Resistor (TFT) with Cold Cathode Fluorescent (CCF) Backlight
Display Area:211 x 158 mm (8.3 x 6.2 in.)
Resolution:640 x 480 pixels
Backlight:100,000 hr LED backlight life
Touchscreen:384 (24 columns x 16 rows)
Touch Cell size:26 x 30 pixels
Application memory:1008K bytes (application screens)
Communication ports:Data Highway Plus (DH+); RS232 (printer)
Input Voltage range:85…264V AC, 47…63 Hz
Operating Temperature:0…55 ° C (32…131 ° F)
Heat Dissipation:39 W (132 BTU/HR)
Part Number/Catalog No.2711-T10C8
Product LinePanelview 1000
Display Size10.1 in.
Display ColorMulti-Color
CommunicationDH Plus (DH+) and Printer (RS-232) Port
Power Source Rating100-240 VAC
Memory256 Kilobytes
Enclosure TypeNEMA Type 12/13 or 4X
UPC10662072718619
Product Lifecycle Status*Discontinued/Obsolete

*The Allen Bradley 2711-T10C8 has been discontinued by the manufacturer, however we specialize in obsolete parts and can likely still supply surplus and/or refurbished replacement 2711-T10C8 units instead of migration.

About 2711-T10C8

The Allen-Bradley graphic operator terminal with catalog number 2711-T10C8 is part of the 2711 PanelView Standard operator terminals. It is specifically part of the PanelView Plus 1000 operator terminals which comes with standard capabilities such as a 10.1-inch colored display screen with resolution of 640 x 480 pixels, touch input interface and integral 1008 Kbytes internal flash memory.

The 2711-T10C8 has specific feature provided by the built-in Data Highway Plus (DH+) communication port and RS232 Printer interface. The DH+ port is used for exchanging data with partner controllers such as PLC5, SLC500, and other Allen-Bradley Programable Logic Controllers (PLC), even with 3rd party devices with support for DH+ protocol as well. DH+ uses a 3-wire cable, which may be implemented in long distances and support communication with one or more controllers. The secondary port which is the RS232 is used for communicating with alarm printers, enabling printing and documenting of alarms and events for historization and reports.

The 2711-T10C8 is a flush mounted to an enclosure and supports horizontal orientation only. It requires mounting clearance of 51 mm or 2 inches on all sides to ensure adequate air flow as well as working space for installation of additional components intended for the operator terminal.

The 2711-T10C8 is mounted to an enclosure rated NEMA Type 12/13, 4X (Indoor use only) IP54, IP65. The required operating temperature is 0…55 ° C (32…131 ° F) with shock and vibration rating of 15 g and 2 g up to 2,000 Hz respectively. Install appropriate cooling and heating devices to maintain the required temperature as well shoch and vibration protection to achieve maximum operating life of the operator terminal.

In addition to communicating with machine controllers, the 2711-T10C8 PanelView 1000 is an excellent input module, allowing the user to input information and commands through its sharp, 10-inch touchscreen. The display is multicolored as is approximately 8.3 inches by 6.2 inches. This display doubles as the touch input touchscreen, with a 1-million press approximate actuation. Its field-replaceable backlight has a 50,000 hour half-life at a consistent temperature of 77 degrees Fahrenheit, and the module’s built-in time-stamping clock runs on batteries that can also be replaced in the field.

The 2711-T10C8 can hold up to 1008 kilobytes of nonvolatile memory, along with 310 kilobytes of application runtime memory. In addition to both of those storage options, the 2711-T10C8 PanelView can support ATA flash memory cards, for additional external memory storage. The 2711-T10C8 uses PanelBuilder32 software only, a versatile, common software that can also be installed on a personal computer.

The 2711-T10C8 is powered by an external voltage supply of 85 and 264 Volts of AC power to operate on a frequency between 47 and 63 Hertz. In general, this module’s applications will consume no more than 55 VA. The 2711-T10C8 weighs between 7 and 8 pounds or 3.2 to 3.6 kilograms. Its size is around 11.11 x 14.58 x 4.40 inches, and it should be kept lower than 6561 feet when mounted. This PanelView 1000 series of modules operates ideally when the surrounding temperature stays lower than 131 degrees Fahrenheit, but higher than 32 (or freezing point). Similarly, it is best stored in a temperature zone between -13 and 158 degrees Fahrenheit. Keep in mind that the 2711-T10C8 cannot withstand more than 2 g of vibration at up to 2000 Hertz and that it is limited to 15 g of shock while operating, and 30 g of shock while off.

FAQ for 2711-T10C8

What type of input does the 2711-T10C8 have?


The 2711-T10C8 has a touchscreen type input.

What kind of storage does the 2711-T10C8 contain?


The 2711-T10C8 has 310 kilobytes of application runtime memory along with 1008 kilobytes of nonvolatile memory and an ATA flash memory port.

What type of enclosure should be used for the 2711-T10C8?


The 2711-T10C8 has enclosure ratings of NEMA Type 12, 13, 4X (indoor use only), IEC IP54, IP65.

How much input power does the 2711-T10C8 require?


The 2711-T10C8 requires between 85 and 264 Volts of AC.

Can I order a warranty with the 2711-T10C8?


The 2711-T10C8 comes with a one-year DO Supply warranty.

Does the 2711-T10C8 have an anti-glare overlay?


Yes, 2711-T10C8 has an anti-glare overlay. Its part number is 2711-NV6T.

Does the 2711-T10C8 have a backlight lamp replacement?


Yes, the 2711-T10C8 has a backlight replacement with the number 2711-NL4; before ordering, check the series of the 2711-T10C8 terminal as Series B, C, D, and F require different backlight replacements.

When installing the 2711-T10C8, what are the recommended panel cut-out dimensions?


The recommended cut-out dimensions when installing the 2711-T10C8 are 10.11 x 13.29 inches (H x W).

What is the embedded communication interface of the 2711-T10C8?


The 2711-T10C8 has Data Highway Plus (DH+) and RS232 Printer interface.

What are the required installation clearance of the 2711-T10C8?


The 2711-T10C8 follows the standard requirement of PanelView Standard operator terminals of 51 mm or 2 inches clearance on all sides of the terminal.

What are the recommended enclosures for use with the 2711-T10C8?


The 2711-T10C8 recommended enclosure is NEMA Type 12/13, 4X (Indoor use only) IP54, IP65.

Technical Description of 2711-T10C8

This Panelview 1000 Display has a DH+ Communication port and a RS-232 Printer Port.  The HMI has a 10.1 inch toushcreen and a memory card slot on the back of the unit. 
Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks $1933.08cartAdd to Cart

Our highly skilled technicians can repair your 2711-T10C8. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks $1933.08cartAdd to Cart

Our highly skilled technicians can repair your 2711-T10C8. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions

Please refer to the manual for more information about the 2711-T10C8 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
2711-T10C8/A, Series A, Rev A Request Quote
2711-T10C8/B, Series B, Rev B Request Quote
2711-T10C8/C, Series C, Rev C Request Quote
2711-T10C8/D, Series D, Rev D Request Quote
2711-T10C8/E, Series E, Rev E Request Quote
2711-T10C8/F, Series F, Rev F Request Quote
2711-T10C8X
2711-T10C8/X, Series X, Rev X Request Quote

Common misspellings:
  • 27l1-T10C8
  • 271l-T10C8
  • 2711-Tl0C8
  • 2711-T1oC8
  • 2711-T10Cb
  • 2711T10C8
PDF
Dimensions

Dimension For 2711-T10C8

Size 10 inch
Input Type Touch
Panel Cutout Height 257 mm (10.11 in)
Panel Cutout Width 338 mm (13.29 in)
Terminal Height 282 mm (11.11 in)
Terminal Width 370 mm (14.58 in)
Terminal Overall Depth 112 mm (4.4 in)
Terminal Mounted Depth 90 mm (3.54 in)
Resolutions

Resolutions For 2711-T10C8

Size 10 inch
Input Type Touch
Display Type Color active matrix TFT
Display Size (Diagonal) 10 in.
Viewing Area 211 x 158 mm (8.3 x 6.2 in.)
Display Resolution 640 x 480
Reviews

Reviews for 2711-T10C8

Internal Review

"The 2711-T10C8 is 10.1-inch is a PanelView 1000 standard operator terminal with colored screen. The main advantage when using this operator terminal compared to the PanelView 600 and PanelView 400 terminals is that the entire PanelView 1000 including the 2711-T10C8 has a larger screen size. With the 10.1-inch display screen, user can create a more detailed process mimic by embedding more symbols and more windows pop-ups can be displayed without covering the entire screen. This enhances the ease of use and interaction with the 2711-T10C8. " -DO Supply Tech