2711-T10C8

|

The 2711-T10C8 terminal is an AC-powered operator terminal from Allen-Bradley. It has been designed and manufactured as a standard type of AC operator terminal from the Allen-Bradley Panelview 1000 product line. Its touchscreen supports full color graphics and it is 10 inches wide. The AC voltage range for the 2711-T10C8 operator terminal is from 85 to 264 Volts AC at a frequency of 47 to 63 Hertz. The 2711-T10C8 operator terminal's touchscreen is analog-resistive.

Ships Today.
Order within 6 hrs 31 mins.
In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with DO Supply's 2-year warranty.
Learn more
  • We sell industrial automation parts backed by our 2-year DO Supply Warranty.

  • Same-day domestic and expedited international shipping with UPS, FedEx, DHL, and more.

  • AMEX, Visa, MasterCard, Discover, wire transfer, and more, plus flexible payment plans.

  • Repair and exchange services for all existing automation products.

  • Reseller Options

    Drop shipping, blind shipping, and account shipping with no extra fees.

Technical specifications for 2711-T10C8

Input TypeTouch
BrandAllen-Bradley
Manufacturer:Rockwell Automation
Product Family:PanelView Standard Terminals
Product Type:PanelView 1000 Standard Operator Terminals
Display Type:Active Matrix Thin-Film Resistor (TFT) with Cold Cathode Fluorescent (CCF) Backlight
Display Area:211 x 158 mm (8.3 x 6.2 in.)
Resolution:640 x 480 pixels
Backlight:100,000 hr LED backlight life
Touchscreen:384 (24 columns x 16 rows)
Touch Cell size:26 x 30 pixels
Application memory:1008K bytes (application screens)
Communication ports:Data Highway Plus (DH+); RS232 (printer)
Input Voltage range:85…264V AC, 47…63 Hz
Operating Temperature:0…55 ° C (32…131 ° F)
Heat Dissipation:39 W (132 BTU/HR)
Part Number/Catalog No.2711-T10C8
Product LinePanelview 1000
Display Size10.1 in.
Display ColorMulti-Color
CommunicationDH Plus (DH+) and Printer (RS-232) Port
Power Source Rating100-240 VAC
Memory256 Kilobytes
Enclosure TypeNEMA Type 12/13 or 4X
UPC10662072718619
Product Lifecycle Status*Discontinued/Obsolete

* The Allen Bradley 2711-T10C8 has been discontinued by the manufacturer, however we specialize in obsolete parts and can likely still supply surplus and/or refurbished replacement 2711-T10C8 units instead of migration.

Rockwell Disclaimer: The product is used surplus. DO Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because DO Supply is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. DO Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. DO Supply also makes no representations as to your right to install any such firmware on the product. DO Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

The Allen-Bradley graphic operator terminal with catalog number 2711-T10C8 is part of the 2711 PanelView Standard operator terminals. It is specifically part of the PanelView Plus 1000 operator terminals which comes with standard capabilities such as a 10.1-inch colored display screen with resolution of 640 x 480 pixels, touch input interface and integral 1008 Kbytes internal flash memory.

The 2711-T10C8 has specific feature provided by the built-in Data Highway Plus (DH+) communication port and RS232 Printer interface. The DH+ port is used for exchanging data with partner controllers such as PLC5, SLC500, and other Allen-Bradley Programable Logic Controllers (PLC), even with 3rd party devices with support for DH+ protocol as well. DH+ uses a 3-wire cable, which may be implemented in long distances and support communication with one or more controllers. The secondary port which is the RS232 is used for communicating with alarm printers, enabling printing and documenting of alarms and events for historization and reports.

The 2711-T10C8 is a flush mounted to an enclosure and supports horizontal orientation only. It requires mounting clearance of 51 mm or 2 inches on all sides to ensure adequate air flow as well as working space for installation of additional components intended for the operator terminal.

The 2711-T10C8 is mounted to an enclosure rated NEMA Type 12/13, 4X (Indoor use only) IP54, IP65. The required operating temperature is 0…55 ° C (32…131 ° F) with shock and vibration rating of 15 g and 2 g up to 2,000 Hz respectively. Install appropriate cooling and heating devices to maintain the required temperature as well shoch and vibration protection to achieve maximum operating life of the operator terminal.

In addition to communicating with machine controllers, the 2711-T10C8 PanelView 1000 is an excellent input module, allowing the user to input information and commands through its sharp, 10-inch touchscreen. The display is multicolored as is approximately 8.3 inches by 6.2 inches. This display doubles as the touch input touchscreen, with a 1-million press approximate actuation. Its field-replaceable backlight has a 50,000 hour half-life at a consistent temperature of 77 degrees Fahrenheit, and the module’s built-in time-stamping clock runs on batteries that can also be replaced in the field. The 2711-T10C8 can hold up to 1008 kilobytes of nonvolatile memory, along with 310 kilobytes of application runtime memory. In addition to both of those storage options, the 2711-T10C8 PanelView can support ATA flash memory cards, for additional external memory storage.

The 2711-T10C8 is powered by an external voltage supply of 85 and 264 Volts of AC power to operate on a frequency between 47 and 63 Hertz. In general, this module’s applications will consume no more than 55 VA. The 2711-T10C8 weighs between 7 and 8 pounds or 3.2 to 3.6 kilograms. Its size is around 11.11 x 14.58 x 4.40 inches, and it should be kept lower than 6561 feet when mounted. This PanelView 1000 series of modules operates ideally when the surrounding temperature stays lower than 131 degrees Fahrenheit, but higher than 32 (or freezing point). Similarly, it is best stored in a temperature zone between -13 and 158 degrees Fahrenheit. Keep in mind that the 2711-T10C8 cannot withstand more than 2 g of vibration at up to 2000 Hertz and that it is limited to 15 g of shock while operating, and 30 g of shock while off.

Revision Part #Also known as
2711-T10C8 Ser A2711-T10C8/A, Series A, Rev A
Request a quote
2711-T10C8 Ser B2711-T10C8/B, Series B, Rev B
Request a quote
2711-T10C8 Ser C2711-T10C8/C, Series C, Rev C
Request a quote
2711-T10C8 Ser D2711-T10C8/D, Series D, Rev D
Request a quote
2711-T10C8 Ser E2711-T10C8/E, Series E, Rev E
Request a quote
2711-T10C8 Ser F2711-T10C8/F, Series F, Rev F
Request a quote
2711-T10C8X2711-T10C8/X, Series X, Rev X
Request a quote
Don't see your particular revision? Contact us now.

Testimonials

4.99 /5.0
Recommended
4.99 average / 907 reviews