2711E-T10C15

 
 
 
 
 
Rated 5 with 15 reviews

top legal disclaimer bottom legal disclaimer
credit cards accepted
better business bureau

2711E-T10C15

Description: 1000e Touch Screen terminal
In Stock Ships Today
Request a quote for 2711E-T10C15

Description:

1000e Touch Screen terminal



Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 2711E-T10C15.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

phone

International
919-205-4392

Rated 5 with 15 reviews

    Technical Specifications for 2711E-T10C15

ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2711E-T10C15
Product LinePanelview 2711E
Display Size10.4-inch
Display ColorColor
Input TypeTouchscreen
CommunicationControlNet
Memory2.25MB On-Board Flash
Input Voltage180-264V AC
Backlight6189-NL2
SoftwarePanelBuilder 1000E
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2711E-T10C15
Product LinePanelview 2711E
Display Size10.4-inch
Display ColorColor
Input TypeTouchscreen
CommunicationControlNet
Memory2.25MB On-Board Flash
Input Voltage180-264V AC
Backlight6189-NL2
SoftwarePanelBuilder 1000E

About 2711E-T10C15

The Allen-Bradley 2711E-T10C15 is a PanelView 1000e Enhanced Operator Terminal.

The PanelView 1000e Enhanced Operator Terminal is equipped with a 10 inch color touch screen at a 640 x 480 resolution and a clip mount with ControlNet (Release 1.5) support. A ControlNet ISA/EISA Interface card is needed for ControlNet communication. The 1784-KTCs card is installed in the Allen-Bradley 2711E-T10C15.

The Terminal features 2.25 megabytes onboard flash memory and Multi-rack RIO or DH+ and ControlNet Scan Classes.

The terminal should only be connected to  its own branch circuit and protected by a fuse or circuit breaker. The incoming power to the Panel View terminal  should be routed by a separate path from the communication cable. 

DO NOT RUN SIGNAL WIRING AND POWER WIRING IN THE SAME CONDUIT

Power and communication lines should cross at right angles. Communication lines can be installed in the same conduit as low level DC I/O lines, less than 10 volts. 

To transfer application files to and from a PanelView terminal, a memory card is needed.

The Allen Bradley 2711E-T10C15 terminals operate if temperature does not exceed 135 degrees celsius.

The terminal should be mounted in an enclosed area to protect the internal circuitry. To ensure adequate ventilation, make sure there is enough space in the enclosure, being mindful of heat provided by other devices in the enclosure. The temperature around the terminals must be between 0 to 55 degrees celsius. 

The remote I/O port can be used to communicate with the remote I/O scanner port on a PLC controller, transfer PaneView applications between a computer and the terminal. 

Please note the the use of abrasive cleansers or solvents are not recommended to clean terminal, do not scrub or use brushes. 

The dimensions of the Allen-Bradley 2711E-T10C15 are 11.11 x 14.58 inches.

FAQ for 2711E-T10C15

Question: Do I need a separate Interface card for ControlNet communication with the 2711E-T10C15 PanelVeiw 1000e Enhanced Operator Terminal?

Answer: Yes, the 2711E-T10C15 PanelVeiw 1000e Enhanced Operator Terminal requires an  ISA/EISA Interface card for ControlNet communication.

 

Question: What is the price of a 2711E-T10C15 PanelVeiw 1000e Enhanced Operator Terminal?

Answer: Submit a quote request, send us an email, or call 800-730-0292 for our best price.

 

Question: What is the display size of the 2711E-T10C15 PanelVeiw 1000e Enhanced Operator Terminal?

Answer: The  2711E-T10C15 features a 10.4 inch color touch screen display at a 640 x 480 resolution.

 

Question: Where can I find repair services for the 2711E-T10C15 PanelVeiw 1000e Enhanced Operator Terminal?

Answer: DO Supply offers repair services for the 2711E-T10C15 PanelVeiw 1000e Enhanced Operator Terminal. For more information or to request a repair quote, please click here to find out more

Repair Services for 2711E-T10C15

Type Lead Time Price Action
Repair Service 3-5 days $1882cartAdd to Cart

Our highly skilled technicians can repair your 2711E-T10C15. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions for 2711E-T10C15

Please refer to the manual for more information about the 2711E-T10C15 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
2711E-T10C15/A, Series A, Rev A Request Quote
2711E-T10C15/B, Series B, Rev B Request Quote
2711E-T10C15/C, Series C, Rev C Request Quote
2711E-T10C15/D, Series D, Rev D Request Quote
2711E-T10C15X
2711E-T10C15/X, Series X, Rev X Request Quote
Common misspellings:
  • 27l1E-T10C15
  • 271lE-T10C15
  • 2711E-Tl0C15
  • 2711E-T1oC15
  • 2711E-T10Cl5
Technical Specifications
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2711E-T10C15
Product LinePanelview 2711E
Display Size10.4-inch
Display ColorColor
Input TypeTouchscreen
CommunicationControlNet
Memory2.25MB On-Board Flash
Input Voltage180-264V AC
Backlight6189-NL2
SoftwarePanelBuilder 1000E
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2711E-T10C15
Product LinePanelview 2711E
Display Size10.4-inch
Display ColorColor
Input TypeTouchscreen
CommunicationControlNet
Memory2.25MB On-Board Flash
Input Voltage180-264V AC
Backlight6189-NL2
SoftwarePanelBuilder 1000E
About

The Allen-Bradley 2711E-T10C15 is a PanelView 1000e Enhanced Operator Terminal.

The PanelView 1000e Enhanced Operator Terminal is equipped with a 10 inch color touch screen at a 640 x 480 resolution and a clip mount with ControlNet (Release 1.5) support. A ControlNet ISA/EISA Interface card is needed for ControlNet communication. The 1784-KTCs card is installed in the Allen-Bradley 2711E-T10C15.

The Terminal features 2.25 megabytes onboard flash memory and Multi-rack RIO or DH+ and ControlNet Scan Classes.

The terminal should only be connected to  its own branch circuit and protected by a fuse or circuit breaker. The incoming power to the Panel View terminal  should be routed by a separate path from the communication cable. 

DO NOT RUN SIGNAL WIRING AND POWER WIRING IN THE SAME CONDUIT

Power and communication lines should cross at right angles. Communication lines can be installed in the same conduit as low level DC I/O lines, less than 10 volts. 

To transfer application files to and from a PanelView terminal, a memory card is needed.

The Allen Bradley 2711E-T10C15 terminals operate if temperature does not exceed 135 degrees celsius.

The terminal should be mounted in an enclosed area to protect the internal circuitry. To ensure adequate ventilation, make sure there is enough space in the enclosure, being mindful of heat provided by other devices in the enclosure. The temperature around the terminals must be between 0 to 55 degrees celsius. 

The remote I/O port can be used to communicate with the remote I/O scanner port on a PLC controller, transfer PaneView applications between a computer and the terminal. 

Please note the the use of abrasive cleansers or solvents are not recommended to clean terminal, do not scrub or use brushes. 

The dimensions of the Allen-Bradley 2711E-T10C15 are 11.11 x 14.58 inches.

FAQ

Question: Do I need a separate Interface card for ControlNet communication with the 2711E-T10C15 PanelVeiw 1000e Enhanced Operator Terminal?

Answer: Yes, the 2711E-T10C15 PanelVeiw 1000e Enhanced Operator Terminal requires an  ISA/EISA Interface card for ControlNet communication.

 

Question: What is the price of a 2711E-T10C15 PanelVeiw 1000e Enhanced Operator Terminal?

Answer: Submit a quote request, send us an email, or call 800-730-0292 for our best price.

 

Question: What is the display size of the 2711E-T10C15 PanelVeiw 1000e Enhanced Operator Terminal?

Answer: The  2711E-T10C15 features a 10.4 inch color touch screen display at a 640 x 480 resolution.

 

Question: Where can I find repair services for the 2711E-T10C15 PanelVeiw 1000e Enhanced Operator Terminal?

Answer: DO Supply offers repair services for the 2711E-T10C15 PanelVeiw 1000e Enhanced Operator Terminal. For more information or to request a repair quote, please click here to find out more

Repairs
Type Lead Time Price Action
Repair Service 3-5 days $1882cartAdd to Cart

Our highly skilled technicians can repair your 2711E-T10C15. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 3-5 days $1882cartAdd to Cart

Our highly skilled technicians can repair your 2711E-T10C15. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions

Please refer to the manual for more information about the 2711E-T10C15 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
2711E-T10C15/A, Series A, Rev A Request Quote
2711E-T10C15/B, Series B, Rev B Request Quote
2711E-T10C15/C, Series C, Rev C Request Quote
2711E-T10C15/D, Series D, Rev D Request Quote
2711E-T10C15X
2711E-T10C15/X, Series X, Rev X Request Quote

Common misspellings:
  • 27l1E-T10C15
  • 271lE-T10C15
  • 2711E-Tl0C15
  • 2711E-T1oC15
  • 2711E-T10Cl5
PDF