Rated 4.5 with 18 reviews

2711-K5A15L1

Description:  The 2711-K5A15L1 is part of the Panelview 550 series. It has a 5.5 inch Monochrome display, Keypad(F1-F10) user input, 24 VDC input power, and has ControlNet Communication and RS-232 Printer Port.

Call 

Request a quote for 2711-K5A15L1
Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 2711-K5A15L1 in 3-5 days.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

Phone

1-800-730-0292

International

919-205-4392


About 2711-K5A15L1

This Panelview 550, the 2711-K5A15L1, is an Allen-Bradley manufactured Panelview with a keypad type input. This module runs PanelBuilder 32 software which can also be run on a personal computer and is powered by an input voltage of 18 to 30 Volts DC, or 24 Volts DC nominally. This unit’s stainless steel keypad is comprised of 10 total function keys maked F1 through F10 with a domed membrane effect, along with an additional, smaller numeric keypad for greater input flexibility. This unit’s display area is a small 120 x 60 millimeter screen with an LCD monochrome display in blue. The unit’s LED backlight will, on average, last for about 100,000 hours before it requires replacement; when this backlight does eventually need to be replaced, a replacement part can be ordered with the number  2711-NL1. In addition to a keypad input, a display screen, and an LED backlight, the 2711-K5A15L1 features a time-stamping battery clock in real time. This clock will mark all important information with a date and time, allowing the user to keep track of all the data being inputted.

The 2711-K5A15L1 supports an ATA card for additional memory to supplement its 170-kilobyte application runtime and a 240 kilobyte nonvolatile RAM memory. It contains a ControlNet port and an RS-232 printer port, although a 2711-NC13 communication cable or cables are required for connection to the network through said ports. This unit is commonly found to support the series A through H and is generally up to date with firmware revisions of 1.00 up to 4.48. At its maximum power consumption, the 2711-K5A15L1 uses around 18 Watts (0.75 A at 24 Volts DC, nominal). It has a number of certifications, including UL508, UL1604 Class 1, Div 2, Groups A through D and T4, and EN61000-6-2:1999.The 2711-K5A15L1 has an approximate weight of 2.7 pounds, with a size roughly around 7 x 10 x 4 inches. The maximum temperature in which this Panelview should be operated is 131 degrees Fahrenheit, with the minimum being 32, or freezing point. While in storage, the surrounding temperature should be monitored to stay in a -4 to 158 degree Fahrenheit zone. To remain fully function, the 2711-K5A15L1 should not be mounted at an altitude greater than 6561 feet, and should not be subjected to a shock greater than 30 g while operating or 50 g while non-operational. This module is rated for a NEMA Type 12, 12, IEC IP45, or IP65 enclosure. Additionally, a NEMA Type 4X enclosure may be used exclusively for the indoor use of the module.

Technical specifications:

Manufacturer:Rockwell Automation
Part Number/Catalog No.:2711-K5A15L1
Product Line:Panelview 550
Display Size:5.5 in.
Display Color:Monochrome LCD blue mode
Input Type:Keypad(F1-F10)
Communication:ControlNet Communication and RS-232 Printer Port
Input Power:24V DC
Software:Panelbuilder 32
Memory:170 KB application runtime
Backlight:2711-NL1
Communication Cable:2711-NC13
Shipping Weight:6 lbs
Shipping Dimensions:14x11x8 inches
Series:A,B,C,D,E,F,G,H
Firmware:1.00-4.48

FAQ

Question: How long does this unit’s backlight last?

Answer: On average, this unit’s backlight will last for 100,000 hours before deteriorating.

 

Question: Can this unit’s backlight be replaced?

Answer: Yes, use the code 2711-NL1 to order a replacement part.

 

Question: What kind of warranty can I add to the 2711-K5A15L1?

Answer: The 2711-K5A15L1 comes with an included 12-month DO Supply warranty.

 

Question: How will the 2711-K5A15L1 be shipped?

Answer: The 2711-K5A15L1 will be shipped with dimensions around 14 x 11 x 9 inches, weighing around 6 pounds. DO Supply uses several different shipping methods, which are listed in the "shipping" tab near the top of this page. Please contact us for more shipping information.

 

Question: Does the 2711-K5A15L1 support any memory card options?

Answer: Yes, in addition to this Panelview’s built-in 240 kilobyte nonvolatile RAM and 170 kilobyte application runtime memory, it does support ATA flash memory cards.

 

Question: How much power does the 2711-K5A15L1 unit consume?

Answer: The 2711-K5A15L1 Panelview 550 consumes a maximum of 18 Watts of power (or 0.75 Amps at 24 Volts DC).

 

Question: Does the 2711-K5A15L1 contain any communication ports?

Answer: Yes, the 2711-K5A15L1 contains an RS-232 printer port and a ControlNet communication port.

Type Lead Time Price Action
Repair Service 3-5 days AskGet Quote

We can Repair your Panelview 550

We have a team of highly trained technicians that can repair your panelview quickly at a great low price. To get a repair quote call 1-800-730-0292 or email sales@dosupply.com. Some of the benefits of our repair process includes:

  • Repair Turnaround of 3-5 Days for Most Panelviews
  • Rush Repairs of 1-3 Days
  • Fast Return of Your Repair via UPS, FedEx, or DHL.
  • If the item is not repairable, you can choose to have it returned to you free of charge or it can be counted as an exchange credit toward a refurbished or new unit if available.
  • Wide range of repairs that can be completed by our highly skilled technicians as shown below.
  • Repair Capabilities:

    Auto Verification and Self-Test Failures

    ERROR! FEHLER! ERREUR! ERRORE!

    • Error 1 STATIC RAM test
    • Error 2 Terminal searching for a file to download.
    • Error 10 Erase boot flash area.
    • Error 11 Copy boot code
    • Error 12 Boot code copy successful
    • Error 13 Boot code copy failed. Check for error after boot code is copied to the onboard flash EPROM.
    • Error 20 Erase firmware from flash EPROM
    • Error 21 Copy firmware to firmware flash memory
    • Error 22 Firmware copy successful
    • Error 23 Firmware copy failed
    • Error 24 Performed CRC base firmware check
    • Error 25 Firmware not compatible with boot code
    • Error 26 Firmware not compatible with hardware
    • Error 30 Watchdog test
    • Error 31 Stuck key test
    • Error 32 Real time clock test
    • Error 33 LCD RAM failed
    • Error 34 Performed CRC extended firmware check
    • Error 40 No executable code to run after boot
    • Error 50 Wrong memory card format
    • Error 60 CPU could not execute code

    We Can Repair Your Hardware failures including:

    • Communication Hardware Faults (Ethernet/IP, DH-485, DH+, ControlNet, and RS-232)
    • Broken Toushcreen/Keypads
    • Broken Glass
    • Displays (Dead/Dim/Lines/Missing Pixels)
    • Dead Backlights
    • Broken Housing/Bezel
    • Power Board Failures

Common misspellings:
27l1-K5A15L1
271l-K5A15L1
2711-K5Al5L1
2711-K5A1511
2711-K5A15Ll
2711-K5A15L1X
2711P-K5A15L1
2711K5A15L1