2711-K5A2

Rated 4.8 with 21 reviews

top legal disclaimer bottom legal disclaimer
credit cards accepted
better business bureau

2711-K5A2

Description: The 2711-K5A2 is part of the Panelview 550 series. It has a 5.5-inch Monochrome display, Keypad(F1-F10) user input, 100 to 240 Volts AC 50 to 60 Hertz input power, and has DH-485 Communication Ports.
Available Now
Request a quote for 2711-K5A2

Description:

The 2711-K5A2 is part of the Panelview 550 series. It has a 5.5-inch Monochrome display, Keypad(F1-F10) user input, 100 to 240 Volts AC 50 to 60 Hertz input power, and has DH-485 Communication Ports.



Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 2711-K5A2 in 3-5 days.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

phone

International
919-205-4392

Rated 4.8 with 21 reviews

    Technical Specifications for 2711-K5A2

ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2711-K5A2
Product LinePanelview 550
Product TypeOperator Terminal
Display Size5.5 inches
Display ColorMonochrome LCD blue mode
Input TypeKeypad(F1-F10)
CommunicationDH-485 Communication Ports
Input Power120 Volts AC
SoftwarePanelbuilder 32
Memory170 KB application runtime
Communication Cable1747-C10
Shipping Weight6 pounds
Shipping Dimensions14x11x8 inches
SeriesA,B,C,D,E,F,G,H
Firmware1.00 to 4.48
Backlight2711-NL1
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2711-K5A2
Product LinePanelview 550
Product TypeOperator Terminal
Display Size5.5 inches
Display ColorMonochrome LCD blue mode
Input TypeKeypad(F1-F10)
CommunicationDH-485 Communication Ports
Input Power120 Volts AC
SoftwarePanelbuilder 32
Memory170 KB application runtime
Communication Cable1747-C10
Shipping Weight6 pounds
Shipping Dimensions14x11x8 inches
SeriesA,B,C,D,E,F,G,H
Firmware1.00 to 4.48
Backlight2711-NL1

About 2711-K5A2

The 2711-K5A2 is an Allen-Bradley PanelView 550 terminal. The obsolete Allen-Bradley PanelView 550 2711-K5A2 is an operator terminal that allows the user to interface with other machines. This PanelView device has a 5.5 in. monochrome LCD blue mode screen. The 2711-K5A2 allows the user to connect to other devices by using the PanelBuilder 32 software and the DH-485 communication port with 1 or more 1747-C10 communication cables. The user is able to control the unit by using the 10-key keypad (with function keys labeled from F1 to F10) to input information and commands.

The Allen-Bradley 2711-K5A2’s features include a nameplate label for displaying product information, a green COMM indicator light to show when the terminal is communicating, a red FAULT indicator light that shows if something is wrong with the terminal’s hardware or firmware, and an access cover that gives users access to the replaceable backlight. Its DH-485 communication port can connect to SLC and MicroLogix controllers, a DH-485 network, or to a Wallmount Power Supply. The 2711-K5A2 terminal is powered using 120 Volts of AC power. This unit has the following internal memory: 170 KB of application runtime memory and 240 KB of nonvolatile memory. This unit has an internal backlight replacement part number of 2711-NL1. The approximate shipping weight and dimensions of the terminal are 6 pounds and 14 x 11 x 8 inches, respectively. The most common series that the 2711-K5A2 comes in includes Series A, B, C, D, E, F, G, and H and the most common firmware that it uses includes versions 1.00 to 4.48.

FAQ for 2711-K5A2

Question: Can I use an ATA memory card with the 2711-K5A2?

Answer: Yes, 2711-K5A2 supports ATA memory cards. 

 

Question: What type of memory does the 2711-K5A2 have?

Answer: The 2711-K5A2 has 240 KB of nonvolatile memory and 170 KB of RAM.

 

Question: What is the backlight life for the 2711-K5A2?

Answer: The 2711-K5A2 backlight life is 100,000 hours. The backlight replacement part number is 2711-NL1.

 

Question: Does 2711-K5A2 have a real-time clock

Answer: Yes, the 2711-K5A2 has a battery-backed real-time clock that will timestamp critical data. 

 

Question: What firmware versions does the 2711-K5A2 use?

Answer: The 2711-K5A2 uses firmware versions 1.00-4.48.

 

Question: What is the price of a 2711-K5A2 PanelView 550 Terminal?

Answer: Submit a quote request, send us an email, or call 800-730-0292 for our best price.

Repair Services for 2711-K5A2

Type Lead Time Price Action
Repair Service 3-5 days $890cartAdd to Cart

We can Repair your Panelview 550

We have a team of highly trained technicians that can repair your panelview quickly at a great low price. To get a repair quote call 1-800-730-0292 or email [email protected]. Some of the benefits of our repair process includes:

  • Repair Turnaround of 3-5 Days for Most Panelviews
  • Rush Repairs of 1-3 Days
  • Fast Return of Your Repair via UPS, FedEx, or DHL.
  • If the item is not repairable, you can choose to have it returned to you free of charge or it can be counted as an exchange credit toward a refurbished or new unit if available.
  • Wide range of repairs that can be completed by our highly skilled technicians as shown below.
  • Repair Capabilities:

    Auto Verification and Self-Test Failures

    ERROR! FEHLER! ERREUR! ERRORE!

    • Error 1 STATIC RAM test
    • Error 2 Terminal searching for a file to download.
    • Error 10 Erase boot flash area.
    • Error 11 Copy boot code
    • Error 12 Boot code copy successful
    • Error 13 Boot code copy failed. Check for error after boot code is copied to the onboard flash EPROM.
    • Error 20 Erase firmware from flash EPROM
    • Error 21 Copy firmware to firmware flash memory
    • Error 22 Firmware copy successful
    • Error 23 Firmware copy failed
    • Error 24 Performed CRC base firmware check
    • Error 25 Firmware not compatible with boot code
    • Error 26 Firmware not compatible with hardware
    • Error 30 Watchdog test
    • Error 31 Stuck key test
    • Error 32 Real time clock test
    • Error 33 LCD RAM failed
    • Error 34 Performed CRC extended firmware check
    • Error 40 No executable code to run after boot
    • Error 50 Wrong memory card format
    • Error 60 CPU could not execute code

    We Can Repair Your Hardware failures including:

    • Communication Hardware Faults (Ethernet/IP, DH-485, DH+, ControlNet, and RS-232)
    • Broken Toushcreen/Keypads
    • Broken Glass
    • Displays (Dead/Dim/Lines/Missing Pixels)
    • Dead Backlights
    • Broken Housing/Bezel
    • Power Board Failures

Revisions for 2711-K5A2

Please refer to the manual for more information about the 2711-K5A2 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
2711-K5A2/A, Series A, Rev A Request Quote
2711-K5A2/B, Series B, Rev B Request Quote
2711-K5A2/C, Series C, Rev C Request Quote
2711-K5A2/D, Series D, Rev D Request Quote
2711-K5A2/E, Series E, Rev E Request Quote
2711-K5A2/F, Series F, Rev F Request Quote
2711-K5A2/G, Series G, Rev G Request Quote
2711-K5A2/H, Series H, Rev H Request Quote
2711-K5A2/X, Series X, Rev X Request Quote
Firmware Revisions

The 2711-K5A2 has several firmware revisions: 2711-K5A2 FRN 1.02, 2711-K5A2 FRN 1.03, 2711-K5A2 FRN 1.06, 2711-K5A2 FRN 1.07, 2711-K5A2 FRN 2.00, 2711-K5A2 FRN 2.01, 2711-K5A2 FRN 3.00, 2711-K5A2 FRN 3.01, 2711-K5A2 FRN 3.13, 2711-K5A2 FRN 3.14, 2711-K5A2 FRN 3.30, 2711-K5A2 FRN 3.40, 2711-K5A2 FRN 4.00, 2711-K5A2 FRN 4.10, 2711-K5A2 FRN 4.20, 2711-K5A2 FRN 4.41, 2711-K5A2 FRN 4.46, and 2711-K5A2 FRN 4.48

Common misspellings:
  • 27l1-K5A2
  • 271l-K5A2

Reviews for 2711-K5A2

Input Method: Keypad Only

"This Panelview 550 only comes with the keypad. " -DO Supply Tech

Technical Specifications
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2711-K5A2
Product LinePanelview 550
Product TypeOperator Terminal
Display Size5.5 inches
Display ColorMonochrome LCD blue mode
Input TypeKeypad(F1-F10)
CommunicationDH-485 Communication Ports
Input Power120 Volts AC
SoftwarePanelbuilder 32
Memory170 KB application runtime
Communication Cable1747-C10
Shipping Weight6 pounds
Shipping Dimensions14x11x8 inches
SeriesA,B,C,D,E,F,G,H
Firmware1.00 to 4.48
Backlight2711-NL1
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2711-K5A2
Product LinePanelview 550
Product TypeOperator Terminal
Display Size5.5 inches
Display ColorMonochrome LCD blue mode
Input TypeKeypad(F1-F10)
CommunicationDH-485 Communication Ports
Input Power120 Volts AC
SoftwarePanelbuilder 32
Memory170 KB application runtime
Communication Cable1747-C10
Shipping Weight6 pounds
Shipping Dimensions14x11x8 inches
SeriesA,B,C,D,E,F,G,H
Firmware1.00 to 4.48
Backlight2711-NL1
About

The 2711-K5A2 is an Allen-Bradley PanelView 550 terminal. The obsolete Allen-Bradley PanelView 550 2711-K5A2 is an operator terminal that allows the user to interface with other machines. This PanelView device has a 5.5 in. monochrome LCD blue mode screen. The 2711-K5A2 allows the user to connect to other devices by using the PanelBuilder 32 software and the DH-485 communication port with 1 or more 1747-C10 communication cables. The user is able to control the unit by using the 10-key keypad (with function keys labeled from F1 to F10) to input information and commands.

The Allen-Bradley 2711-K5A2’s features include a nameplate label for displaying product information, a green COMM indicator light to show when the terminal is communicating, a red FAULT indicator light that shows if something is wrong with the terminal’s hardware or firmware, and an access cover that gives users access to the replaceable backlight. Its DH-485 communication port can connect to SLC and MicroLogix controllers, a DH-485 network, or to a Wallmount Power Supply. The 2711-K5A2 terminal is powered using 120 Volts of AC power. This unit has the following internal memory: 170 KB of application runtime memory and 240 KB of nonvolatile memory. This unit has an internal backlight replacement part number of 2711-NL1. The approximate shipping weight and dimensions of the terminal are 6 pounds and 14 x 11 x 8 inches, respectively. The most common series that the 2711-K5A2 comes in includes Series A, B, C, D, E, F, G, and H and the most common firmware that it uses includes versions 1.00 to 4.48.

FAQ

Question: Can I use an ATA memory card with the 2711-K5A2?

Answer: Yes, 2711-K5A2 supports ATA memory cards. 

 

Question: What type of memory does the 2711-K5A2 have?

Answer: The 2711-K5A2 has 240 KB of nonvolatile memory and 170 KB of RAM.

 

Question: What is the backlight life for the 2711-K5A2?

Answer: The 2711-K5A2 backlight life is 100,000 hours. The backlight replacement part number is 2711-NL1.

 

Question: Does 2711-K5A2 have a real-time clock

Answer: Yes, the 2711-K5A2 has a battery-backed real-time clock that will timestamp critical data. 

 

Question: What firmware versions does the 2711-K5A2 use?

Answer: The 2711-K5A2 uses firmware versions 1.00-4.48.

 

Question: What is the price of a 2711-K5A2 PanelView 550 Terminal?

Answer: Submit a quote request, send us an email, or call 800-730-0292 for our best price.

Repairs
Type Lead Time Price Action
Repair Service 3-5 days $890cartAdd to Cart

We can Repair your Panelview 550

We have a team of highly trained technicians that can repair your panelview quickly at a great low price. To get a repair quote call 1-800-730-0292 or email [email protected]. Some of the benefits of our repair process includes:

  • Repair Turnaround of 3-5 Days for Most Panelviews
  • Rush Repairs of 1-3 Days
  • Fast Return of Your Repair via UPS, FedEx, or DHL.
  • If the item is not repairable, you can choose to have it returned to you free of charge or it can be counted as an exchange credit toward a refurbished or new unit if available.
  • Wide range of repairs that can be completed by our highly skilled technicians as shown below.
  • Repair Capabilities:

    Auto Verification and Self-Test Failures

    ERROR! FEHLER! ERREUR! ERRORE!

    • Error 1 STATIC RAM test
    • Error 2 Terminal searching for a file to download.
    • Error 10 Erase boot flash area.
    • Error 11 Copy boot code
    • Error 12 Boot code copy successful
    • Error 13 Boot code copy failed. Check for error after boot code is copied to the onboard flash EPROM.
    • Error 20 Erase firmware from flash EPROM
    • Error 21 Copy firmware to firmware flash memory
    • Error 22 Firmware copy successful
    • Error 23 Firmware copy failed
    • Error 24 Performed CRC base firmware check
    • Error 25 Firmware not compatible with boot code
    • Error 26 Firmware not compatible with hardware
    • Error 30 Watchdog test
    • Error 31 Stuck key test
    • Error 32 Real time clock test
    • Error 33 LCD RAM failed
    • Error 34 Performed CRC extended firmware check
    • Error 40 No executable code to run after boot
    • Error 50 Wrong memory card format
    • Error 60 CPU could not execute code

    We Can Repair Your Hardware failures including:

    • Communication Hardware Faults (Ethernet/IP, DH-485, DH+, ControlNet, and RS-232)
    • Broken Toushcreen/Keypads
    • Broken Glass
    • Displays (Dead/Dim/Lines/Missing Pixels)
    • Dead Backlights
    • Broken Housing/Bezel
    • Power Board Failures
Type Lead Time Price Action
Repair Service 3-5 days $890cartAdd to Cart

We can Repair your Panelview 550

We have a team of highly trained technicians that can repair your panelview quickly at a great low price. To get a repair quote call 1-800-730-0292 or email [email protected]. Some of the benefits of our repair process includes:

  • Repair Turnaround of 3-5 Days for Most Panelviews
  • Rush Repairs of 1-3 Days
  • Fast Return of Your Repair via UPS, FedEx, or DHL.
  • If the item is not repairable, you can choose to have it returned to you free of charge or it can be counted as an exchange credit toward a refurbished or new unit if available.
  • Wide range of repairs that can be completed by our highly skilled technicians as shown below.
  • Repair Capabilities:

    Auto Verification and Self-Test Failures

    ERROR! FEHLER! ERREUR! ERRORE!

    • Error 1 STATIC RAM test
    • Error 2 Terminal searching for a file to download.
    • Error 10 Erase boot flash area.
    • Error 11 Copy boot code
    • Error 12 Boot code copy successful
    • Error 13 Boot code copy failed. Check for error after boot code is copied to the onboard flash EPROM.
    • Error 20 Erase firmware from flash EPROM
    • Error 21 Copy firmware to firmware flash memory
    • Error 22 Firmware copy successful
    • Error 23 Firmware copy failed
    • Error 24 Performed CRC base firmware check
    • Error 25 Firmware not compatible with boot code
    • Error 26 Firmware not compatible with hardware
    • Error 30 Watchdog test
    • Error 31 Stuck key test
    • Error 32 Real time clock test
    • Error 33 LCD RAM failed
    • Error 34 Performed CRC extended firmware check
    • Error 40 No executable code to run after boot
    • Error 50 Wrong memory card format
    • Error 60 CPU could not execute code

    We Can Repair Your Hardware failures including:

    • Communication Hardware Faults (Ethernet/IP, DH-485, DH+, ControlNet, and RS-232)
    • Broken Toushcreen/Keypads
    • Broken Glass
    • Displays (Dead/Dim/Lines/Missing Pixels)
    • Dead Backlights
    • Broken Housing/Bezel
    • Power Board Failures
Revisions

Please refer to the manual for more information about the 2711-K5A2 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
2711-K5A2/A, Series A, Rev A Request Quote
2711-K5A2/B, Series B, Rev B Request Quote
2711-K5A2/C, Series C, Rev C Request Quote
2711-K5A2/D, Series D, Rev D Request Quote
2711-K5A2/E, Series E, Rev E Request Quote
2711-K5A2/F, Series F, Rev F Request Quote
2711-K5A2/G, Series G, Rev G Request Quote
2711-K5A2/H, Series H, Rev H Request Quote
2711-K5A2/X, Series X, Rev X Request Quote

Common misspellings:
  • 27l1-K5A2
  • 271l-K5A2
PDF
Reviews

Reviews for 2711-K5A2

Input Method: Keypad Only

"This Panelview 550 only comes with the keypad. " -DO Supply Tech