Rated 4.3 with 18 reviews

2711-K9A5

Description:  RS-232 (DH-485) Communication Port

In Stock Ships Today 

Request a quote for 2711-K9A5
Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 2711-K9A5 in 3-5 days.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

Phone

1-800-730-0292

International

919-205-4392

2711-K9A5 Product Details

The Allen-Bradley 2711-K9A5 is a 9-inch monochrome keypad operator input module that provides an interface to the logic controller. It is a member of the PV900 series of PanelView Operator Terminals. It comes with a durable AC gas plasma display. Its RS-232 (DH-485) communication port connects to a DH-485 network, SLC, MicroLogix controller, or Wallmount power supply. This can also be used for transferring applications by connecting with the RS-232 serial port of a computer.
The 2711-K9A5 Monochrome Terminal comes with 1008KB (application screens) of memory. It has a keypad designed for finger operation – bare or gloved. The F1-F16 function keys are used to initiate tasks and operations on the terminal display. The user can input numeric values, including negative values and decimals, with the numeric entry keys. The cursor keys move the cursor for entering the configuration mode and selecting the entry object from the displayed lists. The PV900M requires Panelbuilder 32 software– a Windows program for developing PanelView applications on a computer.  
The PV900M 2711-K9A5 is AC-rated with a supply voltage between 85 and 264V AC at 47-63 Hz with a maximum power consumption of 110 VA. It needs a NEMA Type 12/13, 4X IP54, or IP65 enclosure which is made for indoor use only. Its dimensions measure 9.8 x 15.97 x 4.4 inches. Its installed depth should be 8.65 inches to accommodate the memory card retainer and have enough clearance for memory card insertion. 

The discontinued Allen Bradley Panelview 900 2711-K9A5 allows the user to connect to other devices using Panelbuilder 32 software and an RS-232 (DH-485) communication port with a 2711-NC14 communication cable. The user is able to control the HMI using the Keypad to input information and data. This unit is powered using 120 VAC power. This unit's internal backlight replacement is non-replaceable. The approximate shipping weight and dimensions are 8 lbs. and 18 x 14 x 8 in., respectively. The most common Series are: A, B, C, D, E, F and the most common firmware includes versions 1.00-4.48. The RS-232 (DH-485 protocol) The module connects to MicroLogix and SLC 500 controllers using the DH-485 protocol. The point-to-point configuration provides a separate connection for high-priority data.

Technical specifications:
Manufacturer:Rockwell Automation
Part Number/Catalog No.:2711-K9A5
Product Line:Panelview 900
Display Size:9 in.
Display Color:Monochrome
Input Type:Keypad
Communication:RS-232 (DH-485)
Input Power:120 VAC
Software:Panelbuilder 32
Memory:1008K bytes
Backlight:Non-replaceable
Communication Cable:2711-NC14
Shipping Weight:9 lbs.
Shipping Dimensions:18 x 14 x 8 in
Series :A, B, C, D, E, F
Firmware:1.00-4.48
FAQ

The PanelView Standard operator terminals have multiple models: the 300, 550, 600, 900, 1000, and 1400. The PanelViews are Top Rated Electronic Operator Terminals engineered to suit your needs. The Panelviews have high performance flat panel designs or 14-inch CRTs. These electronic human interfaces feature excellent graphics capabilities. They have high performance functionality in color, gray scale and monochrome displays. The PanelView Standard family offers you rugged electronic human interface solutions. There are many different sizes and configurations to meet your specific requirements. This PanelView Standard class of operator interfaces offers you Flexible Communications and Controller Connectivity. There are several communication options such as Allen-Bradley’s MicroLogix, SLC 500, PLC, and ControlLogix, and other PLC manufacturers. HMI is the acronym for Human Machine Interface, which is an interface between the user and the machine. It provides a graphics-based visualization of an industrial control and monitoring system. It also provides a visual representation of a control system and provides real time data acquisition. A HMI can increase productivity by having a centralized control center that is user-friendly.

Type Lead Time Price Action
Repair Service 3-5 days $1176.48Add to Cart

We can Repair your Panelview 900

We have a team of highly trained technicians that can repair your panelview quickly at a great low price. To get a repair quote call 1-800-730-0292 or email sales@dosupply.com. Some of the benefits of our repair process includes:

Repair Turnaround of 3-5 Days for Most Panelviews

  • Rush Repairs of 1-3 Days
  • Fast Return of Your Repair via UPS, FedEx, or DHL.
  • If the item is not repairable, you can choose to have it returned to you free of charge or it can be counted as an exchange credit toward a refurbished or new unit if available.
  • Wide range of repairs that can be completed by our highly skilled technicians as shown below.
  • RepairCapabilities:

    Auto Verification and Self-Test Failures

    ERROR! FEHLER! ERREUR! ERRORE!

    • Error 1 STATIC RAM test
    • Error 2 Terminal searching for a file to download.
    • Error 10 Erase boot flash area.
    • Error 11 Copy boot code
    • Error 12 Boot code copy successful
    • Error 13 Boot code copy failed. Check for error after boot code is copied to the onboard flash EPROM.
    • Error 20 Erase firmware from flash EPROM
    • Error 21 Copy firmware to firmware flash memory
    • Error 22 Firmware copy successful
    • Error 23 Firmware copy failed
    • Error 24 Performed CRC base firmware check
    • Error 25 Firmware not compatible with boot code
    • Error 26 Firmware not compatible with hardware
    • Error 30 Watchdog test
    • Error 31 Stuck key test
    • Error 32 Real time clock test
    • Error 33 LCD RAM failed
    • Error 34 Performed CRC extended firmware check
    • Error 40 No executable code to run after boot
    • Error 50 Wrong memory card format
    • Error 60 CPU could not execute code

    We Can Repair Your Hardware failures including:

    • Communication Hardware Faults (Ethernet/IP, DH-485, DH+, ControlNet, and RS-232)
    • Broken Toushcreen/Keypads
    • Broken Glass
    • Displays (Dead/Dim/Lines/Missing Pixels)
    • Dead Backlights
    • Broken Housing/Bezel
    • Power Board Failures
Revision Part #
2711-K9A5 | 2711K9A5A
2711-K9A5 | 2711K9A5B
2711-K9A5 | 2711K9A5C
2711-K9A5 | 2711K9A5D
2711-K9A5 | 2711K9A5E
2711-K9A5 | 2711K9A5F
2711-K9A5 | 2711K9A5FRN 1.00
2711-K9A5 | 2711K9A5FRN 1.03
2711-K9A5 | 2711K9A5FRN 1.07
2711-K9A5 | 2711K9A5FRN 2.00
2711-K9A5 | 2711K9A5FRN 2.01
2711-K9A5 | 2711K9A5FRN 2.02
2711-K9A5 | 2711K9A5FRN 2.03
2711-K9A5 | 2711K9A5FRN 3.00
2711-K9A5 | 2711K9A5FRN 3.01
2711-K9A5 | 2711K9A5FRN 3.02
2711-K9A5 | 2711K9A5FRN 3.03
2711-K9A5 | 2711K9A5FRN 3.13
2711-K9A5 | 2711K9A5FRN 3.15
2711-K9A5 | 2711K9A5FRN 3.30
2711-K9A5 | 2711K9A5FRN 3.40
2711-K9A5 | 2711K9A5FRN 4.00
2711-K9A5 | 2711K9A5FRN 4.10
2711-K9A5 | 2711K9A5FRN 4.20
2711-K9A5 | 2711K9A5FRN 4.41
2711-K9A5 | 2711K9A5FRN 4.46
2711-K9A5 | 2711K9A5FRN 4.48
2711-K9A5 | 2711K9A5G
2711-K9A5 | 2711K9A5H
2711-K9A5 | 2711K9A5I
2711-K9A5 | 2711K9A5J
2711-K9A5 | 2711K9A5K
2711-K9A5 | 2711K9A5L
2711-K9A5 | 2711K9A5L1
2711-K9A5 | 2711K9A5L2
2711-K9A5 | 2711K9A5Rev A
2711-K9A5 | 2711K9A5Rev B
2711-K9A5 | 2711K9A5Rev C
2711-K9A5 | 2711K9A5Rev D
2711-K9A5 | 2711K9A5Rev E
2711-K9A5 | 2711K9A5Rev F
2711-K9A5 | 2711K9A5Rev G
2711-K9A5 | 2711K9A5Rev H
2711-K9A5 | 2711K9A5Rev I
2711-K9A5 | 2711K9A5Rev J
2711-K9A5 | 2711K9A5Rev K
2711-K9A5 | 2711K9A5Rev L
2711-K9A5 | 2711K9A5Ser A
2711-K9A5 | 2711K9A5Ser B
2711-K9A5 | 2711K9A5Ser C
2711-K9A5 | 2711K9A5Ser D
2711-K9A5 | 2711K9A5Ser E
2711-K9A5 | 2711K9A5Ser F
2711-K9A5 | 2711K9A5Ser G
2711-K9A5 | 2711K9A5Ser H
2711-K9A5 | 2711K9A5X
2711-K9A5 | Ser A
2711-K9A5 | Ser B
2711-K9A5 | Ser C
2711-K9A5 | Ser D
2711-K9A5 | Ser E
2711-K9A5 | Ser F

Common misspellings:
27l1-K9A5
271l-K9A5
2711-K9A5X
2711P-K9A5
2711K9A5