    Technical Specifications for 2711-K9A9L1

ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2711-K9A9L1
Product LinePanelview 900
Display Size9 inches
Display ColorMonochrome
Input TypeKeypad
CommunicationRS-232 (DH-485) and RS-232 Printer
Input Power24 Volts DC
SoftwarePanelbuilder 32
Memory1008K bytes
BacklightNon-replaceable
Communication Cable2711-NC14
Shipping Weight9 pounds
Shipping Dimensions18 x 14 x 8 inches
Series A, B, C, D, E, F
Firmware1.00-4.48
Product Lifecycle Status*Discontinued/Obsolete

*The Allen Bradley 2711-K9A9L1 has been discontinued by the manufacturer, however we specialize in obsolete parts and can likely still supply surplus and/or refurbished replacement 2711-K9A9L1 units instead of migration.

ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2711-K9A9L1
Product LinePanelview 900
Display Size9 inches
Display ColorMonochrome
Input TypeKeypad
CommunicationRS-232 (DH-485) and RS-232 Printer
Input Power24 Volts DC
SoftwarePanelbuilder 32
Memory1008K bytes
BacklightNon-replaceable
Communication Cable2711-NC14
Shipping Weight9 pounds
Shipping Dimensions18 x 14 x 8 inches
Series A, B, C, D, E, F
Firmware1.00-4.48
Product Lifecycle Status*Discontinued/Obsolete

*The Allen Bradley 2711-K9A9L1 has been discontinued by the manufacturer, however we specialize in obsolete parts and can likely still supply surplus and/or refurbished replacement 2711-K9A9L1 units instead of migration.

s

About 2711-K9A9L1

The 2711-K9A9L1 PanelView 900 is an electronic device by Allen-Bradley which allows for easy interface with a machine and control via the keypad and display screen. The keypad of the 2711-K9A9L1 has 16 function keys which initiate functions on the display terminal and numerical and navigational keys which input numerical and decimal information and select functions on the display screen. Information regarding machine status is displayed graphically on the thin-film transistor color 9-inch screen with a display dimension of 171 x 130 millimeters (6.73i x 5.12 inches) and a resolution of 640 by 480 pixels. The 2711-K9A9L1 also has color indicator lights which display the COMM and FAULT status of the machine using the green and red light indicators.



Default settings and applications on the 2711-K9A9L1 are programmed by a computer connected via the RS-232 communication port, using the PanelBuilt32 software, and the programmed application is stored in the 1008-KB flash memory. Connection with a programmable Logix controller and other devices is established through the RS-232 (DF1) communication port.  The 2711-K9A9L1 also uses the RS-232 printer port for the transmission of files and for connecting to a printer. It has a power terminal with an input power rating of 58W at 2.1 Amps and 24 Volts DC nominal and a voltage range between 18 and 32 Volts DC. It has a NEMA Type 12/13 and 4X enclosure rating and it is designated with a T4 temperature code. The 2711-K9A9L1 has an operational temperature range between 0 and 50 degrees Celsius (32 and 122 degrees Fahrenheit), and a relative humidity range around 5 to 95% without condensation. It weighs 3.18 kilograms (7.0 pounds), and it measures 249 x 406 x 112 millimeters (9.80 x 15.97 x 4.40 inches).



Repair Services for 2711-K9A9L1

Type Lead Time Price Action
Repair Service 2-4 weeks $2652cartAdd to Cart

We can Repair your Panelview 900

We have a team of highly trained technicians that can repair your panelview quickly at a great low price. To get a repair quote call 1-800-730-0292 or email sales@dosupply.com. Some of the benefits of our repair process includes:

Repair Turnaround of 3-5 Days for Most Panelviews

  • Rush Repairs of 1-3 Days
  • Fast Return of Your Repair via UPS, FedEx, or DHL.
  • If the item is not repairable, you can choose to have it returned to you free of charge or it can be counted as an exchange credit toward a refurbished or surplus unit if available.
  • Wide range of repairs that can be completed by our highly skilled technicians as shown below.
  • RepairCapabilities:

    Auto Verification and Self-Test Failures

    ERROR! FEHLER! ERREUR! ERRORE!

    • Error 1 STATIC RAM test
    • Error 2 Terminal searching for a file to download.
    • Error 10 Erase boot flash area.
    • Error 11 Copy boot code
    • Error 12 Boot code copy successful
    • Error 13 Boot code copy failed. Check for error after boot code is copied to the onboard flash EPROM.
    • Error 20 Erase firmware from flash EPROM
    • Error 21 Copy firmware to firmware flash memory
    • Error 22 Firmware copy successful
    • Error 23 Firmware copy failed
    • Error 24 Performed CRC base firmware check
    • Error 25 Firmware not compatible with boot code
    • Error 26 Firmware not compatible with hardware
    • Error 30 Watchdog test
    • Error 31 Stuck key test
    • Error 32 Real time clock test
    • Error 33 LCD RAM failed
    • Error 34 Performed CRC extended firmware check
    • Error 40 No executable code to run after boot
    • Error 50 Wrong memory card format
    • Error 60 CPU could not execute code

    We Can Repair Your Hardware failures including:

    • Communication Hardware Faults (Ethernet/IP, DH-485, DH+, ControlNet, and RS-232)
    • Broken Toushcreen/Keypads
    • Broken Glass
    • Displays (Dead/Dim/Lines/Missing Pixels)
    • Dead Backlights
    • Broken Housing/Bezel
    • Power Board Failures

Revisions for 2711-K9A9L1

Please refer to the manual for more information about the 2711-K9A9L1 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
2711-K9A9L1/A, Series A, Rev A Request Quote
2711-K9A9L1X
2711-K9A9L1/X, Series X, Rev X Request Quote
Firmware Revisions

The 2711-K9A9L1 has several firmware revisions: 2711-K9A9L1-FRN 1.00, 2711-K9A9L1-FRN 1.03, 2711-K9A9L1-FRN 1.07, 2711-K9A9L1-FRN 2.00, 2711-K9A9L1-FRN 2.01, 2711-K9A9L1-FRN 2.02, 2711-K9A9L1-FRN 2.03, 2711-K9A9L1-FRN 3.00, 2711-K9A9L1-FRN 3.01, 2711-K9A9L1-FRN 3.02, 2711-K9A9L1-FRN 3.03, 2711-K9A9L1-FRN 3.13, 2711-K9A9L1-FRN 3.15, 2711-K9A9L1-FRN 3.30, 2711-K9A9L1-FRN 3.40, 2711-K9A9L1-FRN 4.00, 2711-K9A9L1-FRN 4.10, 2711-K9A9L1-FRN 4.20, 2711-K9A9L1-FRN 4.41, 2711-K9A9L1-FRN 4.46, and 2711-K9A9L1-FRN 4.48

Common misspellings:
  • 27l1-K9A9L1
  • 271l-K9A9L1
  • 2711-K9A911
  • 2711-K9A9Ll
  • 2711K9A9L1

Dimensions For 2711-K9A9L1

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For 2711-K9A9L1

Resolutions For 2711-K9A9L1

About

Technical Specifications for 2711-K9A9L1

ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2711-K9A9L1
Product LinePanelview 900
Display Size9 inches
Display ColorMonochrome
Input TypeKeypad
CommunicationRS-232 (DH-485) and RS-232 Printer
Input Power24 Volts DC
SoftwarePanelbuilder 32
Memory1008K bytes
BacklightNon-replaceable
Communication Cable2711-NC14
Shipping Weight9 pounds
Shipping Dimensions18 x 14 x 8 inches
Series A, B, C, D, E, F
Firmware1.00-4.48
Product Lifecycle Status*Discontinued/Obsolete
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2711-K9A9L1
Product LinePanelview 900
Display Size9 inches
Display ColorMonochrome
Input TypeKeypad
CommunicationRS-232 (DH-485) and RS-232 Printer
Input Power24 Volts DC
SoftwarePanelbuilder 32
Memory1008K bytes
BacklightNon-replaceable
Communication Cable2711-NC14
Shipping Weight9 pounds
Shipping Dimensions18 x 14 x 8 inches
Series A, B, C, D, E, F
Firmware1.00-4.48
Product Lifecycle Status*Discontinued/Obsolete

*The Allen Bradley 2711-K9A9L1 has been discontinued by the manufacturer, however we specialize in obsolete parts and can likely still supply surplus and/or refurbished replacement 2711-K9A9L1 units instead of migration.

About 2711-K9A9L1

The 2711-K9A9L1 PanelView 900 is an electronic device by Allen-Bradley which allows for easy interface with a machine and control via the keypad and display screen. The keypad of the 2711-K9A9L1 has 16 function keys which initiate functions on the display terminal and numerical and navigational keys which input numerical and decimal information and select functions on the display screen. Information regarding machine status is displayed graphically on the thin-film transistor color 9-inch screen with a display dimension of 171 x 130 millimeters (6.73i x 5.12 inches) and a resolution of 640 by 480 pixels. The 2711-K9A9L1 also has color indicator lights which display the COMM and FAULT status of the machine using the green and red light indicators.



Default settings and applications on the 2711-K9A9L1 are programmed by a computer connected via the RS-232 communication port, using the PanelBuilt32 software, and the programmed application is stored in the 1008-KB flash memory. Connection with a programmable Logix controller and other devices is established through the RS-232 (DF1) communication port.  The 2711-K9A9L1 also uses the RS-232 printer port for the transmission of files and for connecting to a printer. It has a power terminal with an input power rating of 58W at 2.1 Amps and 24 Volts DC nominal and a voltage range between 18 and 32 Volts DC. It has a NEMA Type 12/13 and 4X enclosure rating and it is designated with a T4 temperature code. The 2711-K9A9L1 has an operational temperature range between 0 and 50 degrees Celsius (32 and 122 degrees Fahrenheit), and a relative humidity range around 5 to 95% without condensation. It weighs 3.18 kilograms (7.0 pounds), and it measures 249 x 406 x 112 millimeters (9.80 x 15.97 x 4.40 inches).



Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks $2652cartAdd to Cart

We can Repair your Panelview 900

We have a team of highly trained technicians that can repair your panelview quickly at a great low price. To get a repair quote call 1-800-730-0292 or email sales@dosupply.com. Some of the benefits of our repair process includes:

Repair Turnaround of 3-5 Days for Most Panelviews

  • Rush Repairs of 1-3 Days
  • Fast Return of Your Repair via UPS, FedEx, or DHL.
  • If the item is not repairable, you can choose to have it returned to you free of charge or it can be counted as an exchange credit toward a refurbished or surplus unit if available.
  • Wide range of repairs that can be completed by our highly skilled technicians as shown below.
  • RepairCapabilities:

    Auto Verification and Self-Test Failures

    ERROR! FEHLER! ERREUR! ERRORE!

    • Error 1 STATIC RAM test
    • Error 2 Terminal searching for a file to download.
    • Error 10 Erase boot flash area.
    • Error 11 Copy boot code
    • Error 12 Boot code copy successful
    • Error 13 Boot code copy failed. Check for error after boot code is copied to the onboard flash EPROM.
    • Error 20 Erase firmware from flash EPROM
    • Error 21 Copy firmware to firmware flash memory
    • Error 22 Firmware copy successful
    • Error 23 Firmware copy failed
    • Error 24 Performed CRC base firmware check
    • Error 25 Firmware not compatible with boot code
    • Error 26 Firmware not compatible with hardware
    • Error 30 Watchdog test
    • Error 31 Stuck key test
    • Error 32 Real time clock test
    • Error 33 LCD RAM failed
    • Error 34 Performed CRC extended firmware check
    • Error 40 No executable code to run after boot
    • Error 50 Wrong memory card format
    • Error 60 CPU could not execute code

    We Can Repair Your Hardware failures including:

    • Communication Hardware Faults (Ethernet/IP, DH-485, DH+, ControlNet, and RS-232)
    • Broken Toushcreen/Keypads
    • Broken Glass
    • Displays (Dead/Dim/Lines/Missing Pixels)
    • Dead Backlights
    • Broken Housing/Bezel
    • Power Board Failures
Type Lead Time Price Action
Repair Service 2-4 weeks $2652cartAdd to Cart

We can Repair your Panelview 900

We have a team of highly trained technicians that can repair your panelview quickly at a great low price. To get a repair quote call 1-800-730-0292 or email sales@dosupply.com. Some of the benefits of our repair process includes:

Repair Turnaround of 3-5 Days for Most Panelviews

  • Rush Repairs of 1-3 Days
  • Fast Return of Your Repair via UPS, FedEx, or DHL.
  • If the item is not repairable, you can choose to have it returned to you free of charge or it can be counted as an exchange credit toward a refurbished or surplus unit if available.
  • Wide range of repairs that can be completed by our highly skilled technicians as shown below.
  • RepairCapabilities:

    Auto Verification and Self-Test Failures

    ERROR! FEHLER! ERREUR! ERRORE!

    • Error 1 STATIC RAM test
    • Error 2 Terminal searching for a file to download.
    • Error 10 Erase boot flash area.
    • Error 11 Copy boot code
    • Error 12 Boot code copy successful
    • Error 13 Boot code copy failed. Check for error after boot code is copied to the onboard flash EPROM.
    • Error 20 Erase firmware from flash EPROM
    • Error 21 Copy firmware to firmware flash memory
    • Error 22 Firmware copy successful
    • Error 23 Firmware copy failed
    • Error 24 Performed CRC base firmware check
    • Error 25 Firmware not compatible with boot code
    • Error 26 Firmware not compatible with hardware
    • Error 30 Watchdog test
    • Error 31 Stuck key test
    • Error 32 Real time clock test
    • Error 33 LCD RAM failed
    • Error 34 Performed CRC extended firmware check
    • Error 40 No executable code to run after boot
    • Error 50 Wrong memory card format
    • Error 60 CPU could not execute code

    We Can Repair Your Hardware failures including:

    • Communication Hardware Faults (Ethernet/IP, DH-485, DH+, ControlNet, and RS-232)
    • Broken Toushcreen/Keypads
    • Broken Glass
    • Displays (Dead/Dim/Lines/Missing Pixels)
    • Dead Backlights
    • Broken Housing/Bezel
    • Power Board Failures
Revisions

Please refer to the manual for more information about the 2711-K9A9L1 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
2711-K9A9L1/A, Series A, Rev A Request Quote
2711-K9A9L1X
2711-K9A9L1/X, Series X, Rev X Request Quote

Common misspellings:
  • 27l1-K9A9L1
  • 271l-K9A9L1
  • 2711-K9A911
  • 2711-K9A9Ll
  • 2711K9A9L1
PDF