2711-T9A1L1

Description:  Panelview 900 Operator Inteface Touchscreen Model with Remote I/O Communication and RS-232 Printer Port Communication and 9 inch Monochrome Display 24 VDC Powered

Available Now 

Request a quote for 2711-T9A1L1
Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 2711-T9A1L1 in 3-5 days.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

Phone

1-800-730-0292

International

919-205-4392

2711-T9A1L1 Product Details

The discontinued Allen-Bradley 2711-T9A1L1 Panelview 900 is an operator terminal that enables the user to interface with a machine. This Human Machine Interface (HMI) has a 9 in. monochrome display. This Panelview allows the user to connect and communicate with other devices using Panelbuilder 32 software and a Remote I/O and RS-232 Printer communication port with a 2711-NC13 communication cable. The user is able to control the HMI using the touchscreen to input information and data. This unit is powered using 24V DC power. This unit has an internal memory of 1008 KB. This unit's internal backlight is non-replaceable. The approximate shipping weight and dimensions are 8 lbs. and 16 x 14 x 8 in., respectively. The most common series are Series A, B, C, D, E, and F. and the most common firmware are versions 1.00-4.48. The Remote I/O terminals connect to a PLC or SLC 500 controller (via 1747-SN module) along with ControlLogix system (via 1756-DHRIO) within the 1771 Remote I/O system. This supports both discrete and block data transferring. Application files are downloaded or uploaded using PanelBuilder32 software by using Remote I/O Pass Through, or directly via the onboard RS-232 printer port which has a PC memory card. The monochrome graphics visualize the monitoring system for the user, allowing for real-time data acquisition. The 2711-T9A1L1 runs on DC voltage.

Technical specifications:
Manufacturer:Rockwell Automation
Part Number/Catalog No.:2711-T9A1L1
Product Line:Panelview 900
Display Size:9 in.
Display Color:Monochrome
Input Type:Touchscreen
Communication:Remote I/O and RS-232 Printer
Input Power:24 VDC
Software:Panelbuilder 32
Memory:1008K bytes
Backlight:Non-replaceable
Communication Cable:2711-NC13
Shipping Weight:8 lbs.
Shipping Dimensions:16 x 14 x 8 in
Series :A, B, C, D, E, F
Firmware:1.00-4.48
FAQ

The PanelView Standard operator terminals have multiple models: the 300, 550, 600, 900, 1000, and 1400. The PanelViews are Top Rated Electronic Operator Terminals engineered to suit your needs. The Panelviews have high performance flat panel designs or 14-inch CRTs. These electronic human interfaces feature excellent graphics capabilities. They have high performance functionality in color, gray scale and monochrome displays. The PanelView Standard family offers you rugged electronic human interface solutions. There are many different sizes and configurations to meet your specific requirements. This PanelView Standard class of operator interfaces offers you Flexible Communications and Controller Connectivity. There are several communication options such as Allen-Bradley’s MicroLogix, SLC 500, PLC, and ControlLogix, and other PLC manufacturers. HMI is the acronym for Human Machine Interface, which is an interface between the user and the machine. It provides a graphics-based visualization of an industrial control and monitoring system. It also provides a visual representation of a control system and provides real time data acquisition. A HMI can increase productivity by having a centralized control center that is user-friendly.

Type Lead Time Price Action
Repair Service 3-5 days AskGet Quote

We can Repair your Panelview 900

We have a team of highly trained technicians that can repair your panelview quickly at a great low price. To get a repair quote call 1-800-730-0292 or email sales@dosupply.com. Some of the benefits of our repair process includes:

Repair Turnaround of 3-5 Days for Most Panelviews

  • Rush Repairs of 1-3 Days
  • Fast Return of Your Repair via UPS, FedEx, or DHL.
  • If the item is not repairable, you can choose to have it returned to you free of charge or it can be counted as an exchange credit toward a refurbished or new unit if available.
  • Wide range of repairs that can be completed by our highly skilled technicians as shown below.
  • RepairCapabilities:

    Auto Verification and Self-Test Failures

    ERROR! FEHLER! ERREUR! ERRORE!

    • Error 1 STATIC RAM test
    • Error 2 Terminal searching for a file to download.
    • Error 10 Erase boot flash area.
    • Error 11 Copy boot code
    • Error 12 Boot code copy successful
    • Error 13 Boot code copy failed. Check for error after boot code is copied to the onboard flash EPROM.
    • Error 20 Erase firmware from flash EPROM
    • Error 21 Copy firmware to firmware flash memory
    • Error 22 Firmware copy successful
    • Error 23 Firmware copy failed
    • Error 24 Performed CRC base firmware check
    • Error 25 Firmware not compatible with boot code
    • Error 26 Firmware not compatible with hardware
    • Error 30 Watchdog test
    • Error 31 Stuck key test
    • Error 32 Real time clock test
    • Error 33 LCD RAM failed
    • Error 34 Performed CRC extended firmware check
    • Error 40 No executable code to run after boot
    • Error 50 Wrong memory card format
    • Error 60 CPU could not execute code

    We Can Repair Your Hardware failures including:

    • Communication Hardware Faults (Ethernet/IP, DH-485, DH+, ControlNet, and RS-232)
    • Broken Toushcreen/Keypads
    • Broken Glass
    • Displays (Dead/Dim/Lines/Missing Pixels)
    • Dead Backlights
    • Broken Housing/Bezel
    • Power Board Failures